Effect of nickel–titanium shape memory metal alloy on bone formation
Source abstract
Abstract
The aim of this study was to determine the biocompatibility of NiTi alloy on bone formation in vivo. For this purpose we used ectopic bone formation assay which goes through all the events of bone formation and calcification. Comparisons were made between Nitinol (NiTi), stainless steel (Stst) and titanium-aluminium (6%)-vanadium (4%) alloy (Ti-6Al-4V), which were implanted for 8 weeks under the fascia of the latissimus dorsi muscle in 3-month-old rats. A light-microscopic examination showed no chronic inflammatory or other pathological findings in the induced ossicle or its capsule. New bone replaced part of the decalcified matrix with mineralized new cartilage and bone. The mineral density was measured with peripheral quantitative computed tomography (pQCT). The total bone mineral density (BMD) values were nearly equal between the control and the NiTi samples, the Stst samples and the Ti-6Al-4V samples had lower BMDs. Digital image analysis was used to measure the combined area of new fibrotic tissue and original implanted bone matrix powder around the implants. There were no significant differences between the implanted materials, although Ti-6Al-4V showed the largest matrix powder areas. The same method was used for measurements of proportional cartilage and new bone areas in the ossicles. NiTi showed the largest cartilage area (p < or = 0.05). Between implant groups the new bone area was largest in NiTi. We conclude that NiTi has good biocompatibility, as its effects on ectopic bone formation are similar to those of Stst, and that the ectopic bone formation assay developed here can be used for biocompatibility studies.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. A summary of recent research on the Nitinol* alloys and their potential application in ocean engineering10.1016/0029-8018(68)90019-X ↗
2. Biocompatibility of Nitinol alloy as an implant material10.1002/jbm.820100505 ↗
3. Memory alloys — new material for implantation in orthopedic surgery
4. Variable curvature shape-memory spatula for laparoscopic surgery10.1007/BF02653258 ↗
5. Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms10.1056/NEJM199701023360103 ↗
6. Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder)10.1136/hrt.82.3.300 ↗
7. Percutaneous closure of secundum atrial septal defect with a new self centring device (“angel wings”)10.1136/hrt.80.5.517 ↗
9. Novel regulators of bone formation10.1126/science.3201241 ↗
10. Bone morphogenetic protein10.1177/00220345710500060601 ↗
11. Tissue transformation into bone in vivo. A potential practical application10.1001/jama.266.14.1953 ↗
12. Lindholm TS, Urist M. A quantitative analysis of new bone formation by induction in composite grafts of bone marrow and bone matrix. Clin Orthop 1980;(150):288–300.10.1097/00003086-198007000-00049 ↗
13. Porous hydroxyapatite ceramics and their ability to be fixed by commercially available screws10.1016/S0142-9612(99)00063-0 ↗
14. Bovine bone activin enhances bone morphogenetic protein-induced ectopic bone formation10.1016/S0021-9258(19)49702-0 ↗
15. Bone induction by composites of bioresorbable carriers and demineralized bone in rats10.1016/0278-2391(92)90231-N ↗
16. The role of cells versus matrix in bone induction10.3109/03008209009152417 ↗
17. Aluminum inhibits bone nodule formation and calcification in vitro
18. In vitro model of aluminum-induced osteomalacia10.1007/BF02405357 ↗
19. Immune inhibition of repair of canine skull trephine defects implanted with partially purified bovine morphogenetic protein10.1007/BF00192304 ↗
20. Evaluation of tissue compatibility of in vitro cultures of embryonic bone
21. Biocompatibility of nickel–titanium shape memory metal and its corrosion behavior in human cell cultures10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G ↗
22. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
23. Quantitative assessment of experimental fracture repair by peripheral computed tomography10.1007/s002239900213 ↗
24. Accuracy and precision study in vitro for peripheral quantitative computed tomography10.1007/BF01622736 ↗
25. Comparison of three-point bending test and peripheral quantitative computed tomography analysis in the evaluation of the strength of mouse femur and tibia10.1016/S8756-3282(98)00076-3 ↗
26. Low dosage of native allogeneic bone morphogenetic protein in repair of sheep calvarial defects10.1016/S0901-5027(97)80804-1 ↗
27. Bone modeling and cell–material interface responses induced by nickel–titanium shape memory alloy after periosteal implantation10.1016/S0142-9612(99)00032-0 ↗
28. In vivo biocompatibility evaluation of nickel–titanium shape memory metal alloy10.1002/(SICI)1097-4636(19980905)41:3<481::AID-JBM19>3.0.CO;2-L ↗
29. Bone healing and mineralization, implant corrosion and trace metals after nickel–titanium shape memory metal intramedullary fixation10.1002/(SICI)1097-4636(19991215)47:4<472::AID-JBM3>3.0.CO;2-Z ↗
30. Histomorphometric analysis of the response of rat tibiae to shape memory alloy (nitinol)10.1016/S0142-9612(96)00051-8 ↗
31. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.0.CO;2-K ↗
32. Comparative in vitro biocompatibility of nickel–titanium, pure nickel, pure titanium, and stainless steel
33. Comparative cell culture effects of shape memory metal (Nitinol), nickel and titanium10.1159/000129231 ↗
34. Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations10.1002/(SICI)1097-4636(1999)48:4<488::AID-JBM14>3.0.CO;2-D ↗