Easy assessment of the biocompatibility of Ni–Ti alloys by in vitro cell culture experiments on a functionally graded Ni–NiTi–Ti material
Source abstract
Abstract
The biocompatibility of nickel-titanium alloys was investigated by single-culture experiments on functionally graded samples with a stepwise change in composition from pure nickel to pure titanium, including an Ni-Ti shape memory alloy for a 50:50 mixture. This approach permitted a considerable decrease of experimental resources by simultaneously studying a full variation of composition. The results indicate a good biocompatibility for a nickel content up to about 50%. The cells used in the biocompatibility studies comprised osteoblast-like osteosarcoma cells (SAOS-2, MG-63), primary human osteoblasts (HOB), and murine fibroblasts (3T3).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Shape Memory Alloy Transformations · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Lipscomb · 1996
2. Yahia · 2000
3. The effect of environmental factors on elastomeric chain and nickel titanium coil springs10.1093/ejo/20.2.169 ↗
4. Laboratory analysis of superelastic NiTi compression springs10.1016/S1350-4533(99)00034-X ↗
5. Bone healing and mineralization, implant corrosion, and trace metals after nickel–titanium shape memory metal intramedullary fixation10.1002/(SICI)1097-4636(19991215)47:4<472::AID-JBM3>3.0.CO;2-Z ↗
6. A new thermo-expandable shape-memory nickel-titanium alloy stent for the management of ureteric structures10.1046/j.1464-410x.1999.00054.x ↗
7. Use of a shape-memory alloy (nitinol) in a removable prostate stent
8. Corrosion testing of stents10.1002/(SICI)1097-4636(1999)48:6<829::AID-JBM10>3.0.CO;2-# ↗
9. Increased corrosion resistance of stent materials by converting surface film of polycrystalline oxide into amorphous oxide10.1002/1097-4636(200011)52:2<323::AID-JBM11>3.0.CO;2-Z ↗
10. Effect of nitinol implant porosity on cranial bone ingrowth and apposition after 6 weeks10.1002/(SICI)1097-4636(199904)45:1<42::AID-JBM6>3.0.CO;2-Q ↗
11. Kang SB, Yoon KS, Lee JH, Kim JS, Gjunter VE, Nam TH. In vivo result of porous TiNi shape memory alloy: bone response and growth. Jpn Inst Met 2002, in press.10.2320/matertrans.43.1045 ↗
12. Effects of sterilization processes on NiTi alloy10.1002/(SICI)1097-4636(200001)49:1<88::AID-JBM11>3.0.CO;2-I ↗
13. Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy10.1016/S0142-9612(98)00224-5 ↗
14. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
15. Biocompatibility of nickel–titanium shape memory metal and its corrosion behavior in human cell cultures10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G ↗
16. In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy10.1002/(SICI)1097-4636(19980905)41:3<481::AID-JBM19>3.0.CO;2-L ↗
17. Bone modeling and cell-material interface responses induced by nickel–titanium shape memory alloy after periosteal implantation10.1016/S0142-9612(99)00032-0 ↗
18. Effect of nickel–titanium shape memory metal alloy on bone formation10.1016/S0142-9612(00)00435-X ↗
19. Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy10.1016/S0142-9612(97)00041-0 ↗
20. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
21. In vitro biocompatibility assessment of a nickel–titanium alloy using electron microscopy in situ end-labeling (EM-ISEL)10.1002/(SICI)1097-4636(199807)41:1<154::AID-JBM18>3.0.CO;2-N ↗
22. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
23. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents10.1002/(SICI)1097-4636(1999)48:2<165::AID-JBM11>3.0.CO;2-# ↗
24. Hard, soft tissue and in vitro cell response to porous nickel–titanium
25. Localized corrosion behavior in simulated human body fluids of commercial Ni–Ti orthodontic wires10.1016/S0142-9612(98)90233-2 ↗
26. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro10.1002/(SICI)1097-4636(19990605)45:3<251::AID-JBM13>3.0.CO;2-5 ↗
27. Comparative in vitro biocompatibility of nickel–titanium, pure nickel, pure titanium, and stainless steel
28. The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells10.1002/1097-4636(200011)52:2<395::AID-JBM21>3.0.CO;2-B ↗
29. Effect of different processing modalities on cytotoxicity and biocompatibility of shape memory alloys
30. Evaulation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in the presence of stress-induced martensite10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P ↗
31. Corrosion and biocompatibility of orthodontic wires10.1023/A:1008953412622 ↗
32. Watari F, Yokoyama A, Kawasaki T, Ohmori M, Hirai T. Gradient tissue reaction induced by functionally graded material. Sixth International Symposium on Functionally Graded Materials, Estes Park, CO, USA 2000.
33. Hansen M. Constitution of binary alloys, 2nd ed. New York: McGraw-Hill, 1958. p. 1050.
34. Bram M, Ahmad-Khanlou A, Buchkremer HP, Stöver D. Powder metallurgy of NiTi alloys with defined shape memory properties. In: Rödhammer P, editor. Proceedings of the 15th PLANSEE Seminar, vol. 1. Austria: Reutte. p. 435–48.
35. Processing of TiNi from elemental powders by hot isostatic pressing10.1016/S0921-5093(99)00550-X ↗