The effects of amorphous carbon films deposited on polyethylene terephthalate on bacterial adhesion
Source abstract
Abstract
There is an increasing interest in developing new methods to reduce bacteria adhesion onto polymeric materials that are used in biomedical implants. The antibacterial behavior on polyethylene terephthalate (PET) treated by acetylene (C2H2) plasma immersion ion implantation-deposition (PIII-D) is investigated. The surface structure of the treated PET is determined by laser Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR). The results show that a thin amorphous polymer-like carbon (PLC) layer is formed on the PET surface. Atomic force micrographs (AFM) show that C2H2 PIII-D significantly changes the surface morphology of PET. The capacities of Staphylococcus aureus (SA) and Staphylococcus epidermidis (SE) to adhere onto PET are quantitatively determined by plate counting and Gamma-ray counting of 125I radio labeled bacteria in vitro. The results indicate that the adhesion of the two kinds of bacteria to PET is suppressed by PLC. The adhesion efficiency of SE on the coated surface is only about 14% of that of the untreated PET surface, and that of SA is about 35% of that of the virgin surface. The electrokinetic potentials of the bacterial cells and substrates are determined by zeta potential measurement. All the substrates as well as the bacterial strain have negative zeta potentials, and it means that bacterial adhesion is not mediated by electrostatic interactions. The surface energy components of the various substrates and bacteria are calculated based on measurements in water, formamide and diiodomethane. The surface free energies obtained are used to calculate the interfacial free energies of adhesion ( deltaFAdh ) of SA and SE onto various substrates, and it is found that bacterial adhesion is energetically unfavorable on the PLC deposited on PET by C2H2 PIII-D.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Polymer Nanocomposite Synthesis and Irradiation · Advanced Sensor and Energy Harvesting Materials · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Thrombogenicity of polyethylene oxide-bonded Dacron sewing ring in a mechanical heart valve
2. The efficacy of controlled antibiotic release for prevention of polyethyleneterephthalate- (Dacron-) related infection in cardiovascular surgery10.1016/0267-6605(93)90102-D ↗
3. Beneficial use of fibroblast growth factor 2 and RGTA, a new family of heparan mimics, for endothelialization of PET prostheses10.1002/1097-4636(2001)58:1<1::AID-JBM10>3.0.CO;2-8 ↗
4. Delayed stenosis following placement of a polyethylene terephthalate endograft in the cervical carotid artery. Report of three cases10.3171/jns.2003.98.2.0421 ↗
5. Infections related to medical devices10.7326/0003-4819-89-5-764 ↗
6. Device-related infections10.1086/324190 ↗
7. Infectious disorders of prosthetic valves and intravascular devices
8. Prosthetic valve endocarditis10.1161/01.CIR.69.2.223 ↗
9. Risk factors for the development of prosthetic valve endocarditis10.1161/01.CIR.72.1.31 ↗
10. Surface implantation treatments to prevent infection complications in short term devices10.1016/S1389-0344(02)00037-0 ↗
11. Application of electron spectroscopy and surface modification techniques in the development of anti-microbial coatings for medical devices10.1016/S0368-2048(01)00338-3 ↗
12. Surface thiocyanation of plasticized poly(vinyl chloride) and its effect on bacterial adhesion10.1016/S0142-9612(03)00022-X ↗
13. Investigation of diamond-like carbon formed on PET film by plasma-source ion implantation using C2H2 and CH410.1016/S0168-583X(03)00869-3 ↗
14. Amorphous carbon layer deposition on plastic film by PSII10.1016/S0040-6090(02)00803-9 ↗
15. Diamond carbon deposition on plastic films by plasma source ion implantation10.1116/1.1458942 ↗
16. Measurement of the surface free energy of bacterial cell surfaces and its relevance for adhesion10.1128/aem.48.5.980-983.1984 ↗
17. Analysis of different approaches for evaluation of surface energy of microbial cells by contact angle goniometry10.1016/S0001-8686(02)00004-0 ↗
18. On the selection of test liquids for the evaluation of acid–base properties of solid surfaces by contact angle goniometry10.1006/jcis.1995.1060 ↗
19. Synthesis of amorphous carbon films by plasma-based ion implantation using ECR plasma with a mirror field10.1016/S0257-8972(02)00096-8 ↗
20. On the predominant electron-donicity of polar solid surfaces10.1080/00218469708015214 ↗
21. Modification of surface of Dacron materials by UV irradiation for prevention of microbial adhesion
22. Conditioning film-induced modification of substratum physicochemistry-analysis by contact angles10.1006/jcis.1996.0452 ↗
23. The role of polymeric surface smoothness of biliary stents in bacterial adhesion, biofilm deposition, and stent occlusion10.1016/S0016-5107(93)70120-0 ↗
24. Release of gentamicin from acrylic bone cement10.2106/00004623-198870100-00015 ↗