Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones
Source abstract
Abstract
The immuno-inflammatory responses to stainless-steel (21 implants in 20 patients) and titanium plates (22 implants in 20 patients) used in the treatment of long bone fractures were studied immunohistochemically. All fractures healed without complications. In the soft tissue adjacent to the surface of the implants a dark discolouration of the tissue was visible in 18/21 stainless-steel and 20/22 titanium plates. Tissue specimens of all patients contained positive staining for macrophages (CD68-positive cells). Serial sections showed that the majority of cells were found to express the HLA-DR molecule indicating their activation. Many of the macrophages were surrounded by clusters of T-lymphocytes (CD3-positive cells). 17 out of 21 steel specimens and 15 out of 22 titanium specimens showed the infiltration of moderate amounts of cytotoxic T-lymphocytes (CD8-positive cells). Moderate amounts of B-lymphocytes (CD79alpha positive cells) were evident in four patients with steel and six patients with titanium implants. The results of the present study clearly demonstrate the presence of a marked inflammation and tissue reaction in the soft tissue covering stainless-steel and titanium plates used for internal fixation of fractures of long bones independently from the material used.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Changes in nonosseous tissue adjactent to titanium implants10.1002/jbm.820070607 ↗
2. Immunocompetent cells adjacent to stainless steel and titanium miniplates and screws10.1111/j.1600-0722.1995.tb00010.x ↗
3. Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures10.1016/S1010-5182(96)80049-7 ↗
4. Human monocyte/macrophage respons to cobalt-chromium corrosion products and titanium particles in patients with total joint replacement10.1002/jor.1100150107 ↗
5. Hierholzer · 1991
6. Ruedi · 1975
7. Characterization of trace ion release from embedded metal implants in the rabbit10.2106/00004623-196244020-00008 ↗
8. Immune response to synthetic materials—sensitization of patients receiving orthopaedic implants10.1097/00003086-199605000-00009 ↗
9. Titanium and titanium alloys
10. Osseointegration of titanium implants10.3109/17453678608994393 ↗
11. The limited contact dynamic compression plate (LC-DCP)10.1007/BF00636166 ↗
12. The concept of biological plating using the limited contact dynamic compression plate
13. Sensitivity to titanium—a cause of implant failure?10.1302/0301-620X.73B1.1991768 ↗
14. Human macrophage response to retrieved titanium alloy particles in vitro10.1097/00003086-199601000-00032 ↗
15. Human osteoblast-like cells phagocytose metal particles and express the macrophage marker CD68 in vitro10.1302/0301-620X.82B2 .9730 ↗
16. The pathology of the joint tissues and its clinical relevance in prosthesis failure
17. Immunocytochemical characterization of monoclonal anti-HLA-DR antibodies
18. The effect of titanium debris on soft tissue response10.1007/BF00058968 ↗
19. Foreign body reaction to polymeric debris following total hip arthroplasty10.1097/00003086-198703000-00035 ↗
20. Immunopathological response to loose cementless acetabular components10.1302/0301-620X.73B1.1991772 ↗
21. T-lymphocytes and titanium aluminium vanadium (TiAlV) alloy10.1016/0267-6605(93)90028-6 ↗
22. Immunohistochemical study of the soft tissue around long-term skin-penetrating titanium implants10.1016/0142-9612(95)93858-B ↗
23. Tissue response in relation to type of wear particles around failed hip arthroplasties10.1016/S0883-5403(08)80093-9 ↗
24. Cementless total joint arthroplasty prostheses with titanium alloy articular surfaces. A human retrieval analysis10.1097/00003086-199012000-00020 ↗
25. In vitro reaction to orthopaedic biomaterials by macrophages and lymphocytes isolated from patients undergoing revision surgery10.1016/S0142-9612(00)00181-2 ↗
26. Induction of interleukin-6 release in human osteoblast-like cells exposed to titanium particles in vitro10.1007/s00223001125 ↗
27. Induction of macrophage C–C-chemokine expression by titanium alloy and bone cement particles10.1302/0301-620X.81B1.8884 ↗
28. Black staining around titanium alloy prostheses—an orthopaedic enigma10.1302/0301-620X.73B4.2071632 ↗
29. The ionization of metal implants in living tissues10.2106/00004623-196042010-00007 ↗
30. Metal release from titanium fixtures during placement in the mandible
31. Metal ion release from titanium-based prosthetic segmental replacement of long bones in baboons10.1002/jor.1100010411 ↗
32. In vitro corrosion testing of titanium surgical implant alloys10.1002/jbm.820130206 ↗
33. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement10.2106/00004623-200004000-00002 ↗
34. Titanium, a metal for surgery10.2106/00004623-195133020-00021 ↗
35. Sintered fiber metal composites as a basis for attachment of implants to bone10.2106/00004623-197153010-00009 ↗
36. Titanium plate fixation10.1097/00005131-199608000-00005 ↗
37. Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system10.1007/BF00636167 ↗
38. Custom titanium plating for failed nonunion or delayed internal fixation of femoral fractures10.1097/00003086-198809000-00034 ↗
39. Influence of materials for fixation implants on local infection10.1302/0301-620X.78B4.0780647 ↗
40. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs10.1302/0301-620X.63B3.7263759 ↗
41. The comparison of steel and titanium dynamic compression plates for internal fixation of 256 fractures of the tibia10.1016/S0020-1383(79)80072-8 ↗