journal article·2003-12

A new austenitic stainless steel with negligible nickel content: an in vitro and in vivo comparative investigation

M Fini, N. Nicoli Aldini, P. Torricelli, G. Giavaresi, V. Borsari, H. Lenger, J. Bernauer, R. Giardino, R. Chiesa, A. Cigada

Biomaterials· Volume 24· Issue 27
Publisher page

Abstract

New nickel (Ni)-reduced stainless-steel metals have recently been developed to avoid sensitivity to Ni. In the present study, an austenitic Ni-reduced SSt named P558 (P558, Böhler, Milan, Italy) was studied in vitro on primary osteoblasts and in vivo after bone implantation in the sheep tibia, and was compared to ISO 5832-9 SSt (SSt) and Ti6Al4V. Cells were cultured directly on P558 and Ti6Al4V. Cells cultured on polystyrene were used as controls. Osteoblast proliferation, viability and synthetic activity were evaluated at 72 h by assaying WST1, alkaline phosphatase activity (ALP), nitric oxide, pro-collagen I (PICP), osteocalcin (OC), transforming growth factor-beta1 (TGFbeta-1) and interleukin-6 (IL-6) after 1.25(OH)2D3 stimulation. Under general anaesthesia, four sheep were submitted for bilateral tibial implantation of P558, SSt and Ti6Al4V rods. In vitro results demonstrated that the effect of P558 on osteoblast viability, PICP, TGF beta-1, tumor necrosis factor-alpha production did not significantly differ from that exerted by Ti6Al4V and controls. Furthermore, P558 enhanced osteoblast differentiation, as confirmed by ALP and OC levels, and reduced IL-6 production. At 26 weeks, the bone-to-implant contact was higher in P558 than in SSt (28%, p<0.005) and Ti6Al4V (4%, p<0.05), and was higher in Ti6Al4V than in SSt (22%, p<0.005). The tested materials did not affect bone microhardness in pre-existing host bone as evidenced by the measurements taken at 1000 microm from the bone-biomaterial interface (F=1.89, ns). At the bone-biomaterial interface the lowest HV value was found for SSt, whereas no differences in HV were observed between materials (F=1.55, ns). The current findings demonstrate P558 biocompatibility both in vitro and in vivo, and osteointegration processes are shown to be significantly improved by P558 as compared to the other materials tested.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Cutaneous metal sensitivity in patients with orthopaedic injuries10.1097/00005131-200102000-00002 ↗
2. Corrosion of metal orthopaedic implants
3. Titanium serum and urine levels in rabbits with a titanium implant in the absence of wear10.1016/0142-9612(96)00023-3 ↗
4. Sister chromatid exchanges and ion release in patients wearing fracture fixation devices10.1002/(SICI)1097-4636(200004)50:1<21::AID-JBM4>3.0.CO;2-R ↗
5. Atomic absorption spectrophotometry (AAS) for the evaluation of metallosis in prostheses and artficial organs use10.1177/039139889902200712 ↗
6. Evaluation of systemic metal diffusion after spinal pedicular fixation with titanium alloy and stainless steel systems10.1177/039139880102400108 ↗
7. Widespread dissemination of metal debris from implants10.1302/0301-620X.76B5.8083255 ↗
8. Release of metal ions from dental implant materials in vivo10.1002/jbm.820251204 ↗
9. Sensitivity to titanium. A cause of implant failure10.1302/0301-620X.73B1.1991768 ↗
10. Systemic effects of implanted prostheses made of cobalt–chromium alloys10.1007/BF00393876 ↗
11. Wear induced by motion between bone and titanium or cobalt-chrome alloys10.1302/0301-620X.76B5.8083256 ↗
12. Metal ion release from titanium-based prosthetic segmental replacements of long bones in baboons10.1002/jor.1100010411 ↗
13. Stainless steel in bone surgery
14. Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces10.1002/1097-4636(200102)54:2<209::AID-JBM7>3.0.CO;2-7 ↗
15. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation10.1002/1097-4636(20011205)57:3<404::AID-JBM1183>3.0.CO;2-W ↗
16. Titanium alloys in total joint replacement—a material science perspectives10.1016/S0142-9612(97)00146-4 ↗
17. Hypersensitivity to metallic biomaterials10.1016/S0142-9612(99)00235-5 ↗
18. Relating nickel-induced tissue inflammation to nickel release in vivo10.1002/jbm.1052 ↗
19. Metal-associated angiosarcoma of bone10.1097/00003086-200203000-00031 ↗
20. The in vitro effects of metal cations on eukaryotic cell metabolism10.1002/jbm.820250907 ↗
21. In vitro reaction of macrophages to metal ions from dental biomaterials10.1016/0109-5641(95)80056-5 ↗
22. Effect of Ni ions on expression of intercellular adhesion molecule 1 by endothelia cells10.1002/(SICI)1097-4636(199708)36:2<145::AID-JBM2>3.0.CO;2-K ↗
23. Titanium alloy enhances bone-pedicle screw fixation10.1007/s005860050218 ↗
24. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP)
25. Unalloyed titanium for implants in bone surgery10.1016/S0020-1383(00)80016-9 ↗
26. Induction of interleukin-6 release inhuman osteoblast-like cells exposed to titanium particles in vitro10.1007/s00223001125 ↗
27. Combined effect of titanium particles and TNF-alpha on the production of IL-6 by osteoblast-like cells10.1002/1097-4636(200011)52:2<382::AID-JBM19>3.0.CO;2-V ↗
28. The cytotoxic effect of titanium particles phagocytosed by osteoblasts10.1002/(SICI)1097-4636(19990905)46:3<399::AID-JBM13>3.0.CO;2-B ↗
29. Prosthetic metals interfere with the functions of human osteoblast cells in vitro10.1097/00003086-199706000-00030 ↗
30. Titanium particles induce the immediate early stress responsive chemokines IL-8 and MCP-1 in osteoblasts10.1016/S0736-0266(01)00154-1 ↗
31. The influence of biomaterial on patterns of failure after cemented total hip replacement10.1007/s00264-002-0367-z ↗
32. Interaction between topography and coating in the formation of bone nodules in culture for hydroxyapatite- and titanium-coated micromachined surfaces10.1002/1097-4636(20010915)56:4<494::AID-JBM1121>3.0.CO;2-X ↗
33. TGF-beta1 secretion of ROS-17/2.8 cultures on NiTi implant material10.1016/S0142-9612(02)00023-6 ↗
34. Incorporation of stainless steel, titanium and vitallium in bone10.1016/0020-1383(75)90174-6 ↗
35. A histological study of stainless steel and titanium screws in bone10.1016/0266-4356(90)90129-9 ↗
37. Mechanical and histological analysis of bone-pedicle screw interface in vivo
38. The effect of pulsed electromagnetic fields on the osteointegration of hydroxyapatite implants in cancellous bone10.1016/S0736-0266(01)00158-9 ↗
39. Titanium alloy osseointegration in cancellous and cortical bone of ovariectomized animals
40. Microhardness testing of bone
41. Pizzoferrato A10.1002/jbm.820290604 ↗
42. Biochemical, scanning electron microscopy, and microhardness analyses of the bone pin interface in hydroxyapatite coated vs. uncoated pins10.1097/00005131-199704000-00003 ↗
43. Microstructural investigation of bone cement interface10.1002/jbm.820290605 ↗
44. Microhardness and anisotropy of the vital osseous interface and endosseous implants supporting bone10.1002/jor.1100160110 ↗
45. Osteoinduction, osteoconductionm and osseointegration10.1007/s005860100282 ↗
46. The healing of autologous bone grafts after varying degrees of surgical trauma10.1302/0301-620X.62B3.6997321 ↗