Silicon excretion from bioactive glass implanted in rabbit bone
Source abstract
Abstract
Bioactive glass granules were implanted in the tibiae of rabbits in order to determine the pathway of the silicon released from bioactive glass in vivo. We traced and quantified the silicon released by obtaining 24-h urine samples and blood samples for up to 7 months after implantation. Bone tissue as well as the following organs were resected for chemical and histopathological analyses: kidney, liver, lung, lymph nodes, and spleen. The urinary silicon of the implanted group was significantly higher than in the control group. From the data, the calculated average excretion rate was approximately 1.8 mg/day, and as such, the amount of implanted silicon was excreted within statistical bounds in 24 weeks. At this point, only elevated concentrations of silicon were found at the implant site and not in the other organs. The concentrations of silicon measured in the urine were well below saturation. Since no significant increase in silicon was found in any of the organs including the kidney, the increased silicon excretion rate was within the physiological capacity of rabbits. Therefore, it can be concluded that the resorbed silica gel is harmlessly excreted in soluble form through the urine.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Facial Trauma and Fracture Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Bioactive glass particulate material as a filler for bone lesions10.1111/j.1365-2842.1991.tb01689.x ↗
2. Bonding mechanisms at the interface of ceramic prosthetic materials
3. A histological comparison of the tissue interface of bioglass and silica glass10.1002/jbm.820210408 ↗
4. Toxicology and biocompatibility of bioglasses10.1002/jbm.820150605 ↗
5. Biocompatibility of silicates for medical use
6. Lai W, Garino J, Ducheyne P. Excretion of silicon from bioactive glass implanted in rabbit muscle 2000, submitted for publication.10.4028/www.scientific.net/KEM.192-195.581 ↗
7. Comparative experimental investigations with bioglass (L.L. Hench) and Al2O3-ceramic coated with mod. bioglass. II. Results of experiments with loaded implants10.1007/BF00397960 ↗
8. Comparative histocompatibility testing of seven calcium phosphate ceramics10.1016/0142-9612(81)90043-0 ↗
9. Biodegradation behavior of various calcium phosphate materials in bone tissue10.1002/jbm.820170505 ↗
10. Livingston TL, Garino J, Ducheyne P. The combination of osteoprogenitor cells and bioactive ceramic scaffold promote the return of functional bone. J Biomed Mater Res 2000.
11. Stimulation of biological function with bioactive glass10.1557/S0883769400030992 ↗
12. Transformation of bioactive glass granules into Ca–P shells in vitro10.1002/(SICI)1097-4636(200002)49:2<264::AID-JBM16>3.0.CO;2-2 ↗
13. Schwarz K. A bound form of silicon in glycosaminoglycans and polyuronides. Proceedings of the National Academy of Sciences of the United States of America, vol. 70, 1973. p. 1608–12.10.1073/pnas.70.5.1608 ↗
14. The silicon content of body fluids10.1177/003693308202700105 ↗
15. The concentration and distribution of some stable elements in healthy human tissues from the United Kingdom10.1016/0048-9697(73)90024-7 ↗
16. Distribution of silicon in the adult rat and rhesus monkey10.1016/S0006-3061(00)81019-4 ↗
17. Baumann · Hoppe-Seylers's Z. Physiol Chem · 1960 · 320 · 1110.1515/bchm2.1960.320.1.11 ↗
18. Iler · 1979
19. Policard · J Urol Med Chir · 1960 · 65 · 585
20. Scheel · AMA Arch Ind Hyg Occup Med · 1953 · 8 · 564
21. Gye · British J Experim Pathol · 1922 · 3 · 75
22. Policard · J Biophys Biochem Cytol · 1961 · 9 · 23610.1083/jcb.9.1.236 ↗
23. Silica metabolism in guinea pigs10.1139/o59-020 ↗