Collapse pressures of biodegradable stents
Source abstract
Abstract
Biodegradable stent prototypes were produced from poly L-lactic acid polymers with different molecular weights. The effects of molecular weight, drug incorporation and stent design on the collapse pressure of the stents were evaluated. While molecular weights did not show a significant effect on the collapse pressure of the stents, drug incorporation at high percentage decreased the collapse pressure of the stents substantially. Cryogenic fracture surfaces showed significant drug agglomeration as the concentration increased. The design of the stent was also found to a have significant effect on the collapse pressure. The stent produced from the same material has a higher collapse pressure when the load bearing surface area is increased.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Material Properties and Processing · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. Transluminally placed coil-spring endarterial tube grafts10.1097/00004424-196909000-00008 ↗
2. Nonsurgical implantation of a vascular ring prosthesis using thermal shape memory Ti/Ni alloy (nitinol wire)
3. Self expanding metallic stents for small vessels10.1148/radiology.162.2.3797661 ↗
4. Self expanding metallic stents10.1148/radiology.163.3.3575726 ↗
5. Balloon expandable intracoronary stents in adult dog
6. A novel stent deployment in the treatment of acute or threatened closure complicating balloon angioplasty10.1016/0735-1097(93)90774-U ↗
7. Serial angiographic follow-up after palmaz-schatz stent implantation10.1016/0735-1097(93)90368-B ↗
8. Fate of lesion related side branches after coronary artery stenting10.1016/0735-1097(93)90589-S ↗
9. Percutaneous implantation of a new intracoronary stent in pigs10.1016/0002-8703(91)90268-M ↗
10. Stenting of coronary arteries10.1016/0735-1097(91)90951-5 ↗
11. New revascularization devices
12. Zidar JP, Lincoff MA, Stack RS. In: Topol EJ, editor. Textbook of Interventional Cardiology, 2nd ed., New York: Saunders, 1994 [Chapter 47].
13. Interventional cardiac catherization at duke medical center
14. Mechanical features of the Duke biodegradable intravascular stent10.1016/0735-1097(91)91907-V ↗
15. Initial and 6-month results of biodegradable poly l-lactic acid coronary stents in humans10.1161/01.CIR.102.4.399 ↗
16. Eury RP. Multilayered Biodegradable Stent Method of Manufacture. US Patent 5443458; 1995.
17. Buscemi PJ, Stejskal EA, Palme II, Donald F, Wang LX. Method for making a Biodegradable Stent. US Patent 5968092, 1999.
18. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization10.1056/NEJMoa012843 ↗
19. Kinloch AJ, Young RJ. Fracture Behaviour of Polymers. Essex, England: Applied Science Publishers, 1983. p. 238–9.
20. The drug–eluting stent