In vivo imaging of neuronal calcium during electrode implantation: Spatial and temporal mapping of damage and recovery
Source abstract
Abstract
Implantable electrode devices enable long-term electrophysiological recordings for brain-machine interfaces and basic neuroscience research. Implantation of these devices, however, leads to neuronal damage and progressive neural degeneration that can lead to device failure. The present study uses in vivo two-photon microscopy to study the calcium activity and morphology of neurons before, during, and one month after electrode implantation to determine how implantation trauma injures neurons. We show that implantation leads to prolonged, elevated calcium levels in neurons within 150 μm of the electrode interface. These neurons show signs of mechanical distortion and mechanoporation after implantation, suggesting that calcium influx is related to mechanical trauma. Further, calcium-laden neurites develop signs of axonal injury at 1-3 h post-insert. Over the first month after implantation, physiological neuronal calcium activity increases, suggesting that neurons may be recovering. By defining the mechanisms of neuron damage after electrode implantation, our results suggest new directions for therapies to improve electrode longevity.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces · Advanced Memory and Neural Computing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Cortical neural prosthetics10.1146/annurev.neuro.27.070203.144233 ↗
2. Brain-controlled interfaces: movement restoration with neural prosthetics10.1016/j.neuron.2006.09.019 ↗
3. Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities10.1523/JNEUROSCI.3879-08.2008 ↗
4. Review: human Intracortical recording and neural decoding for brain-computer interfaces10.1109/TNSRE.2017.2677443 ↗
5. Optogenetic investigation of the variable neurovascular coupling along the interhemispheric circuits10.1177/0271678X18755225 ↗
6. Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration10.1088/1741-2560/6/5/056003 ↗
7. Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses10.1088/1741-2560/9/4/046020 ↗
8. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays10.1016/j.expneurol.2005.04.020 ↗
9. The roles of blood-derived macrophages and resident microglia in the neuroinflammatory response to implanted intracortical microelectrodes10.1016/j.biomaterials.2014.05.084 ↗
10. Understanding the inflammatory tissue reaction to brain implants to improve neurochemical sensing performance10.1021/acschemneuro.7b00403 ↗
11. Brain tissue responses to neural implants impact signal sensitivity and intervention strategies10.1021/cn500256e ↗
12. Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes10.1016/j.biomaterials.2014.07.039 ↗
13. In vivo spatiotemporal dynamics of NG2 glia activity caused by neural electrode implantation10.1016/j.biomaterials.2018.02.037 ↗
14. Large-scale recording of neuronal ensembles10.1038/nn1233 ↗
15. The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes10.1038/nrn3241 ↗
16. Intracellular features predicted by extracellular recordings in the Hippocampus in vivo10.1152/jn.2000.84.1.390 ↗
17. Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response10.1016/j.biomaterials.2014.08.006 ↗
18. Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays10.1016/j.jneumeth.2014.12.010 ↗
19. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex10.1016/S0165-0270(98)00031-4 ↗
20. Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex10.1088/1741-2560/8/4/045005 ↗
21. Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates10.1088/1741-2560/10/6/066014 ↗
22. Glial responses to implanted electrodes in the brain10.1038/s41551-017-0154-1 ↗
23. Functional remodeling of subtype-specific markers surrounding implanted neuroprostheses10.1152/jn.00162.2017 ↗
24. Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new Emphasis on the Biological Interface10.1088/1741-2552/aa9dae ↗
25. Neuroadhesive L1 coating attenuates acute microglial attachment to neural electrodes as revealed by live two-photon microscopy10.1016/j.biomaterials.2016.10.054 ↗
26. In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through10.1088/1741-2560/9/6/066001 ↗
27. Relationship between intracortical electrode design and chronic recording function10.1016/j.biomaterials.2013.07.016 ↗
28. Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo10.1016/j.biomaterials.2016.02.013 ↗
29. Thy1-GCaMP6 transgenic mice for neuronal population imaging in vivo10.1371/journal.pone.0108697 ↗
30. Calcium dysregulation and homeostasis of neural calcium in the molecular mechanisms of neurodegenerative diseases provide multiple targets for neuroprotection10.1089/ars.2010.3359 ↗
31. A recoverable state of axon injury persists for hours after spinal cord contusion in vivo10.1038/ncomms6683 ↗
32. A mechanistic analysis of nondisruptive axonal injury: a review10.1089/neu.1997.14.419 ↗
33. Traumatic axonal injury induces calcium influx modulated by tetrodotoxin-sensitive sodium channels10.1523/JNEUROSCI.21-06-01923.2001 ↗
34. Direct visualization of membrane architecture of myelinating cells in transgenic mice expressing membrane-anchored EGFP10.1002/dvg.22751 ↗
35. Imaging neuronal subsets in transgenic mice expressing multiple spectral variants of GFP10.1016/S0896-6273(00)00084-2 ↗
36. Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion10.1088/1741-2560/3/3/002 ↗
37. A response surface model predicting the in vivo insertion behavior of micromachined neural implants10.1088/1741-2560/9/1/016005 ↗
38. Transcranial amelioration of inflammation and cell death after brain injury10.1038/nature12808 ↗
39. Two-photon imaging of chronically implanted neural electrodes: sealing methods and new insights10.1016/j.jneumeth.2015.10.007 ↗
40. Neural and hemodynamic responses to optogenetic and sensory stimulation in the rat somatosensory cortex10.1038/jcbfm.2015.10 ↗
41. Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes10.1109/TBME.2005.862530 ↗
42. Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances10.1109/TNSRE.2005.847373 ↗
43. Saalfeld · 2010
44. Ultrasoft microwire neural electrodes improve chronic tissue integration10.1016/j.actbio.2017.02.010 ↗
45. Strain and rate-dependent neuronal injury in a 3D in vitro compression model of traumatic brain injury10.1038/srep30550 ↗
46. Synaptic elimination and protection after minimal injury depend on cell type and their prelesion structural dynamics in the adult cerebral cortex10.1523/JNEUROSCI.0254-13.2013 ↗
47. Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new Emphasis on the Biological Interface10.1088/1741-2552/aa9dae ↗
48. Picture thresholding using an iterative selection method10.1109/TSMC.1978.4310039 ↗
49. Identification of neuronal network properties from the spectral analysis of calcium imaging signals in neuronal cultures
50. Spectral analysis of calcium oscillations10.1126/stke.2582004pl15 ↗
51. Direct, live imaging of cortical spreading depression and anoxic depolarisation using a fluorescent, voltage-sensitive dye10.1038/sj.jcbfm.9600569 ↗
52. Dynamic changes in neural circuit topology following mild mechanical injury in vitro10.1007/s10439-011-0390-6 ↗
53. Mechanical trauma induces immediate changes in neuronal network activity10.1088/1741-2560/2/4/011 ↗
54. Imaging neural activity using thy1-GCaMP transgenic mice10.1016/j.neuron.2012.07.011 ↗
55. Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators10.1038/nmeth.1398 ↗
56. Mechanical stretch to neurons results in a strain rate and magnitude-dependent increase in plasma membrane permeability10.1089/089771503770195885 ↗
57. Acute plasmalemma permeability and protracted clearance of injured cells after controlled cortical impact in mice10.1038/sj.jcbfm.9600544 ↗
58. In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain10.1016/j.jneumeth.2014.08.012 ↗
59. Partial interruption of axonal transport due to microtubule breakage accounts for the formation of periodic varicosities after traumatic axonal injury10.1016/j.expneurol.2011.10.030 ↗
60. Mechanical breaking of microtubules in axons during dynamic stretch injury underlies delayed elasticity, microtubule disassembly, and axon degeneration10.1096/fj.09-142844 ↗
61. Single-neuron NMDA receptor phenotype influences neuronal rewiring and reintegration following traumatic injury10.1523/JNEUROSCI.4172-13.2014 ↗
62. Axonal pathology in traumatic brain injury10.1016/j.expneurol.2012.01.013 ↗
63. A materials roadmap to functional neural interface design10.1002/adfm.201701269 ↗
64. Cortical spreading depolarization: pathophysiology, implications, and future directions10.1016/j.jocn.2015.08.004 ↗
65. Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate10.1088/1741-2560/13/4/046019 ↗
66. Unique electrophysiological and impedance signatures between encapsulation types: an analysis of biological Utah array failure and benefit of a biomimetic coating in a rat model10.1016/j.biomaterials.2018.01.025 ↗
67. A materials roadmap to functional neural interface design10.1002/adfm.201701269 ↗
68. Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping10.1088/1741-2560/7/4/046011 ↗
69. Electrophysiological abnormalities in both axotomized and nonaxotomized pyramidal neurons following mild traumatic brain injury10.1523/JNEUROSCI.0881-12.2012 ↗
70. Functional connectivity structure of cortical calcium dynamics in anesthetized and awake mice10.1371/journal.pone.0185759 ↗
71. Sensory cortex underpinnings of traumatic brain injury deficits10.1371/journal.pone.0052169 ↗
72. Traumatic brain injury increases cortical glutamate network activity by compromising GABAergic control
73. Traumatic brain injury and neuronal functionality changes in sensory cortex
74. Diffuse traumatic brain injury initially attenuates and later expands activation of the rat somatosensory whisker circuit concomitant with neuroplastic responses10.1016/j.brainres.2010.01.067 ↗
75. Long-term changes in the material properties of brain tissue at the implant–tissue interface10.1088/1741-2560/10/6/066001 ↗
76. Photoelectric artefact from optogenetics and imaging on microelectrodes and bioelectronics: new Challenges and Opportunities10.1039/C5TB00108K ↗
77. Nanostructured coatings for improved charge delivery to neurons
78. Tissue damage thresholds during therapeutic electrical stimulation10.1088/1741-2560/13/2/021001 ↗
79. Electrical stimulation of excitable tissue: design of efficacious and safe protocols10.1016/j.jneumeth.2004.10.020 ↗
80. Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation10.1016/j.jneumeth.2004.02.019 ↗
81. Stimulus induced pH changes in cochlear implants: an in vitro and in vivo study10.1114/1.1397793 ↗
82. Electrical stimulation of excitable tissue: design of efficacious and safe protocols10.1016/j.jneumeth.2004.10.020 ↗
83. Minireview: pH and synaptic transmission10.1016/j.febslet.2013.04.045 ↗
84. Polyethylene glycol repairs membrane damage and enhances functional recovery: a tissue engineering approach to spinal cord injury10.1007/s12264-013-1364-5 ↗
85. Intravenous polyethylene glycol successfully treats severe acceleration-induced brain injury in rats as assessed by magnetic resonance imaging10.1227/01.NEU.0000342406.43816.13 ↗
86. Poloxamer 188 (P188) as a membrane resealing reagent in biomedical applications10.2174/1872208311206030200 ↗
87. Chronic in vivo evaluation of PEDOT/CNT for stable neural recordings10.1109/TBME.2015.2445713 ↗
88. Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces10.1038/nmat3468 ↗
89. Chronic in vivo stability assessment of carbon fiber microelectrode arrays10.1088/1741-2560/13/6/066002 ↗
90. Insertion of linear 8.4 mu m diameter 16 channel carbon fiber electrode arrays for single unit recordings10.1088/1741-2560/12/4/046009 ↗
91. In vivo evaluation of a neural stem cell-seeded prosthesis10.1088/1741-2560/6/2/026005 ↗
92. Seeding neural progenitor cells on silicon-based neural probes10.3171/2010.1.JNS09313 ↗
93. The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interface10.1016/j.biomaterials.2010.09.033 ↗
94. In vivo effects of L1 coating on inflammation and neuronal health at the electrode-tissue interface in rat spinal cord and dorsal root ganglion10.1016/j.actbio.2012.06.034 ↗
95. Carbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasone10.1016/j.biomaterials.2011.05.020 ↗
96. Electrochemically controlled release of dexamethasone from conducting polymer polypyrrole coated electrode10.1016/j.jconrel.2005.10.027 ↗
97. Electrically controlled drug delivery from graphene oxide nanocomposite films10.1021/nn406223e ↗
98. Minocycline increases quality and longevity of chronic neural recordings10.1088/1741-2560/4/2/L01 ↗
99. The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes10.1016/j.biomaterials.2013.05.035 ↗
100. Controlled release of anti-inflammatory agent alpha-MSH from neural implants10.1016/j.jconrel.2005.05.012 ↗