Poly(ε-caprolactone) and poly(ε-caprolactone)-polyvinylpyrrolidone-iodine blends as ureteral biomaterials: characterisation of mechanical and surface properties, degradation and resistance to encrustation in vitro
Source abstract
Abstract
This study describes the physicochemical properties and in vitro resistance to encrustation of solvent cast films composed of either poly(epsilon-caprolactone) (PCL), prepared using different ratios of high (50,000) to low (4000) (molecular weight) m.wt., or blends of PCL and the polymeric antimicrobial complex, poly(vinylpyrrolidone)-iodine (PVP-I). The incorporation of PVP-I offered antimicrobial activity to the biomaterials. Films were characterised in terms of mechanical (tensile analysis, dynamic mechanical thermal analysis) and surface properties (dynamic contact angle analysis, scanning electron microscopy), whereas degradation (at 37 degrees C in PBS at pH 7.4) was determined gravimetrically. The resistance of the films to encrustation was evaluated using an in vitro encrustation model. Reductions in the ratio of high:low-m.wt. PCL significantly reduced the ultimate tensile strength, % elongation at break and the advancing contact angle of the films. These effects were attributed to alterations in the amorphous content and the more hydrophilic nature of the films. Conversely, there were no alterations in Young's modulus, the viscoelastic properties and glass-transition temperature. Incorporation of PVP-I did not affect the mechanical or rheological properties of the films, indicative of a limited interaction between the two polymers in the solid state. Manipulation of the high:low m.wt. ratio of PCL significantly altered the degradation of the films, most notably following longer immersion periods, and resistance to encrustation. Accordingly, maximum degradation and resistance to encrustation was observed with the biomaterial composed of 40:60 high:low m.wt. ratios of PCL; however, the mechanical properties of this system were considered inappropriate for clinical application. Films composed of either 50:50 or 60:40 ratio of high:low m.wt. PCL offered an appropriate compromise between physicochemical properties and resistance to encrustation. This study has highlighted the important usefulness of degradable polymer systems as ureteral biomaterials.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Infectious Aortic and Vascular Conditions · Ureteral procedures and complications · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Tunney · 1999 · vol. 310 · 558
2. Sequential polyurethane-poly(methylmethacrylate) interpenetrating polymer networks as ureteral biomaterials10.1023/A:1018596109061 ↗
3. Ureteral stents
4. Medical device-related infection10.1097/00013542-199610000-00002 ↗
5. Mechanical performance of polyurethane ureteral stents in vitro and ex vivo10.1016/S0142-9612(97)00070-7 ↗
6. Materials used in urological devices
7. Resistance of catheters coated with modified hydrogel to encrustation during an in vitro test10.1007/BF00510524 ↗
8. Comparative assessment of ureteral stent biomaterial encrustation10.1016/0142-9612(96)89780-8 ↗
9. Characterisation and assessment of a novel poly(ethylene oxide)/polyurethane composite hydrogel (Aquavene®) as a ureteral stent biomaterial10.1002/(SICI)1097-4636(19980315)39:4<642::AID-JBM20>3.0.CO;2-7 ↗
10. Bioabsorbable and biodegradable stents in urology10.1089/end.1997.11.391 ↗
11. A bioresorbable uretheral stent10.1007/BF00590042 ↗
12. Preliminary in-vitro release studies of chlorhexidine from poly(ε-caprolactone) films prepared by solvent evaporation10.1016/0378-5173(92)90218-Q ↗
13. Chlorhexidine release from poly(ε-caprolactone) films prepared by solvent evaporation10.1016/S0378-5173(96)04675-3 ↗
14. A comparative study of the microbial anti-adherence capacities of three antimicrobial agents10.1111/j.1365-2710.1987.tb00552.x ↗
15. Dynamic mechanical analysis of polymeric systems of pharmaceutical and biomedical significance10.1016/S0378-5173(98)00337-8 ↗
16. The effect of molecular weight on the rheological and tensile properties of PCL10.1016/0378-5173(95)04404-3 ↗
17. Storage effects on the thermomechanical properties of polyvinylpyrrolidone-iodine containing poly(ε-caprolactone) blends10.1179/146580100101541175 ↗
18. The role of physiological conditions in the oropharynx on the adherence of respiratory isolates to endotracheal tube polyvinylchloride10.1016/S0142-9612(96)00170-6 ↗
19. Biodegradable drug delivery systems based on aliphatic polyesters
20. Callister WD. Materials science, engineering: an introduction. 4th ed. New York: Wiley, 1997. p. 465–510.
21. Polycaprolactone, its copolymers
22. Effect of molecular weight on the tensile strength of glassy plastics
23. Mechanical behaviour of sequential polyurethane-poly(methylmethacrylate) interpenetrating networks10.1016/0032-3861(88)90197-8 ↗
24. Polyurethane-poly(methylmethacrylate) interpenetrating networks10.1016/0032-3861(93)90428-D ↗
25. Aliphatic polyesters10.1002/app.1981.070261124 ↗
26. Sustained drug delivery systems. II10.1002/jps.2600681219 ↗
27. Stability study of nanoparticles of PCL, poly(d,l-lactide) and poly(d,l-lactide-co-glycolide)10.1016/0142-9612(96)00049-X ↗
28. Development of a model for the assessment of biomaterial encrustation in the upper urinary tract10.1016/0142-9612(96)84679-5 ↗
29. Methacrylate polymers and copolymers as urinary tract biomaterials10.1016/S0378-5173(97)04902-8 ↗