journal article·2006-03

Evaluation of polymer and self-assembled monolayer-coated silicone surfaces to reduce neural cell growth

Kruti R. Patel, Haiying Tang, William E. Grever, Ka Yuen Simon Ng, Jianming Xiang, Richard F. Keep, Ting Cao, James P. McAllister

Biomaterials· Volume 27· Issue 8
Publisher page

Abstract

The development of silicone catheters has improved the treatment of hydrocephalus. Unfortunately, the functionality of the catheters used for the treatment of hydrocephalus is compromised by cell obstruction. In this study silicone surfaces coated with biopolymers (heparin and hyaluronan) and self-assembled monolayers (SAM) (octadecyltrichlorosilane-OTS and fluoroalkylsilane-FAS) were employed to investigate the effect of these coatings on astrocyte and choroid plexus cell growth in vitro. Compared to unmodified silicone, FAS surfaces significantly reduced (p<0.05) astrocyte proliferation, heparin (p<0.001) and hyaluronan (p<0.001) surfaces significantly increased astrocyte growth, while no significant difference was observed on OTS surfaces. A similar trend was observed for choroid plexus cell growth on heparin (p<0.05) and hyaluronan (p<0.05) coatings, however, no significant reduction in cell growth was observed on FAS- or OTS-coated surfaces compared to silicone. Low cell growth may be attributed to hydrophobicity of the surfaces (FAS 112.2+/-2.6 degrees , OTS 102.2+/-1.3 degrees). Contact angle measurements confirmed the stability of the hydrophobic and hydrophilic properties of all the coatings on the silicone surfaces for 30 days. Surface roughness did not play an important role on cell growth. Silicone shunts coated with SAMs may be suitable for future clinical applications to improve the treatment of hydrocephalus.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular Mechanics and Interactions · Cerebrospinal fluid and hydrocephalus · Retinal and Macular Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Implanted ventricular shunts in the United States: The billion-dollar-a-year cost of hydrocephalus treatment10.1227/01.NEU.0000146206.40375.41 ↗
2. Toporek C, Robinson K. Hydrocephalus: a guide for patients, families & friends, 1999.
3. A rare cause of right atrial mass: thrombus formation and infection complicating a ventriculoatrial shunt for hydrocephalus10.1016/S0090-3019(99)00044-0 ↗
4. Effect of hydrophilic coating on microorganism colonization in silicone tubing10.1007/s00701-004-0262-z ↗
5. Bacterial adhesion to surfactant-modified silicone surfaces10.1227/01.NEU.0000103673.13196.7F ↗
6. Methods and complications in surgical cerebrospinal fluid shunting10.1016/S1042-3680(18)30025-1 ↗
7. Cerebrospinal fluid shunt infections. Report of 41 cases and a critical review of the literature10.1159/000120455 ↗
8. VP shunts—what is the commonest complication?10.1186/1743-8454-1-S1-S25 ↗
9. Protein adsorption to hydrocephalus shunt catheters: CSF protein adsorption10.1136/jnnp.64.5.643 ↗
10. Biological reactions to cerebrospinal fluid shunt devices: a review of the cellular pathology10.1097/00006123-199802000-00064 ↗
11. Malfunctioning ventriculoperitoneal shunts. Clinical and pathological features10.3171/jns.1982.56.3.0411 ↗
12. Improvement of a chronic rat model for peritoneal dialysis by using heparin-coated catheters
13. Comparison of outcomes up to six months of heparin-coated with noncoated stents after percutaneous coronary intervention for acute myocardial infarction10.1016/j.amjcard.2003.11.067 ↗
14. Layer-by-layer deposition of hyaluronic acid and poly-l-lysine for patterned cell co-cultures10.1016/j.biomaterials.2003.10.033 ↗
15. Pavesio A, Renier D, Cassinelli C, Morra M. Anti-adhesive surfaces through hyaluronan coatings. Med Device Technol 1997; 8: 20–1, 24–7.
16. Chemical and topographical surface modification for control of central nervous system cell adhesion10.1023/A:1009982306118 ↗
17. Microlithographic determination of axonal: dendritic polarity in cultured hippocampal neurons10.1016/S0165-0270(98)00047-8 ↗
18. Reduced mouse fibroblast cell growth by increased hydrophilicity of microbial polyhydroxyalkanoates via hyaluronan coating10.1016/S0142-9612(03)00356-9 ↗
19. Self-assembled monolayers with different terminating groups as model substrates for cell adhesion studies10.1016/j.biomaterials.2003.09.069 ↗
20. Osteoclast adhesion and activity on synthetic hydroxyapatite, carbonated hydroxyapatite, and natural calcium carbonate: relationship to surface energies10.1002/(SICI)1097-4636(199905)45:2<140::AID-JBM9>3.0.CO;2-I ↗
21. Creating long-lived superhydrophobic polymer surfaces through mechanically assembled monolayers10.1126/science.290.5499.2130 ↗
22. Spreading on heterogeneous surfaces in a complete wetting regime10.1021/la990185r ↗
23. Attachment and growth of periodontal cells on smooth and rough titanium
24. In vitro cell attachment of osteoblast-like cells to titanium
25. Optimization of surface micromorphology for enhanced osteoblast responses in vitro
26. Adhesion of mammalian cells to polymer surfaces: from physical chemistry of surfaces to selective adhesion on define patterns10.1016/S0142-9612(98)00055-6 ↗
27. Integrins: versatility, modulation and signaling in cell adhesion10.1016/0092-8674(92)90115-S ↗
28. Surface chemistry modulates focal adhesion composition and signaling through changes in integrin binding10.1016/j.biomaterials.2004.01.062 ↗
29. Physicochemical and blood compatibility characterization of polypyrrole surface functionalized with heparin10.1002/bit.10757 ↗