journal article·2010-07

Oxygen mass transfer in a human tissue-engineered trachea

Efrem Curcio, Paolo Macchiarini, Loredana De Bartolo

Biomaterials· Volume 31· Issue 19
Publisher page

Abstract

On June 2008, the first human tissue-engineered trachea replacement was performed using decellularized (de-antigenised) cadaveric donor trachea, seeded with recipient epithelial cells on the internal surface of the graft and mesenchymal stem-cell-derived chondrocytes on the external. During the follow-up, cytological analysis at 4 postoperative days showed a migration of the stem-cells derived chondrocytes from the outer to the inner surface of the first 2 cm of the graft length. With the aim to rationalize these clinical findings, and under the hypothesis that cellular migration is driven by the oxygen gradients developing from the external part of the construct (exposed to O(2) deficiency) towards the better oxygenated epithelial region, an accurate computational model of oxygen transport in the trachea engineered construct was developed and solved using finite element method (FEM). Results confirm that critical limitation to oxygen transport prevalently occurs from proximal to middle section, within the first 2.8 cm of longitudinal length, in good agreement with experimental observation. In the proximal section, recognized as the most critical part of the engineered construct, the severe O(2) mass transfer limitation causes a drastic reduction of the diffusive flux within a distance of 650 microm. At cell density of 1 x 10(7)cells/cm(3), the 30% c.a of the total section area is under oxygen deficiency (O(2) partial pressure below the critical threshold of 38 mmHg). Along the whole tracheal construct, the Thiele modulus ranges within 2.3 and 3.7 in the external chondrocyte compartment, confirming thus the importance of the mass transfer limitation to oxygen diffusion rate. In general, the efficiency of the O(2) transport reduces considerably in the region close to proximal section.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Tracheal and airway disorders · Trauma Management and Diagnosis · Tissue Engineering and Regenerative Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Clinical transplantation of a tissue-engineered airway10.1016/S0140-6736(08)61598-6 ↗
2. Bioreactors for tissue mass culture: design, characterisation, and recent advances10.1016/j.biomaterials.2005.05.057 ↗
3. Design criteria for a modular tissue-engineered construct10.1089/ten.2006.0245 ↗
4. Surface-modified 3D starch-based scaffold for improved endothelialization for bone tissue engineering10.1039/b819089e ↗
5. Modelling nutrient transport in hollow fibre membrane bioreactor for growing bone tissue with consideration of multi-component interactions10.1016/j.ces.2007.06.024 ↗
6. Computational simulation of oxygen diffusion in aortic valve leaflet for tissue engineering applications
7. Nutrient gradients in engineered cartilage: metabolic kinetics measurement and mass transfer modeling10.1002/bit.21887 ↗
8. Analysis of oxygen transport in a diffusion-limited model of engineered heart tissue10.1002/bit.21295 ↗
9. Oxygen gradients correlate with cell density and cell viability in engineered cardiac tissue10.1002/bit.20722 ↗
10. Tissue engineering of a bioartificial pancreas: modeling the cell environment and device function10.1021/bp00032a001 ↗
11. Mass transfer and metabolic reactions in hepatocyte spheroids cultured in rotating wall gas-permeable membrane system10.1016/j.biomaterials.2007.08.033 ↗
12. Human hepatocyte functions in a crossed hollow fiber membrane bioreactor10.1016/j.biomaterials.2009.01.011 ↗
13. A double-chamber rotating bioreactor for the development of tissue engineered hollow organ implants: concept to clinical trials10.1016/j.biomaterials.2009.07.018 ↗
14. A model of the hemodynamic response and oxygen delivery to brain10.1006/nimg.2002.1078 ↗
15. Assessing tissue oxygenation10.4037/ccn2002.22.3.22 ↗
16. Cussler · 1984
17. Computational evaluation of oxygen and shear stress distributions in 3D perfusion culture systems: macro-scale and micro-structured models10.1016/j.jbiomech.2008.07.023 ↗
18. Conway · 1999
19. Perfusion cultures and modelling of oxygen uptake with three-dimensional chondrocytes pellets10.1023/A:1008967830977 ↗
20. Design of bioreactors for mesenchymal stem cell tissue engineering10.1002/jctb.1918 ↗
21. Increased oxidative metabolism in cow tracheal epithelial cells cultured at air–liquid interface10.1165/ajrcmb.16.1.8998080 ↗
22. Computational modelling of combined cell population dynamics and oxygen transport in engineered tissue subject to interstitial perfusion10.1080/10255840701318404 ↗
23. Diffusive and convective transport through hollow fiber membranes for liver cell culture10.1016/j.jbiotec.2005.02.004 ↗
24. Engineering principles of clinical cell-based tissue engineering10.2106/00004623-200407000-00029 ↗
25. Mathematical model of oxygen distribution in engineered cardiac tissue with parallel channel array perfused with culture medium containing oxygen carriers10.1152/ajpheart.00787.2004 ↗
26. Determination of oxygen gradients in engineered tissue using a fluorescent sensor10.1002/bit.10352 ↗
27. Computational fluid dynamics modeling of steady-state momentum and mass transport in a bioreactor for cartilage tissue engineering10.1021/bp020087n ↗