journal article·2021-08

Molecular magnetic resonance imaging of Alpha-v-Beta-3 integrin expression in tumors with ultrasound microbubbles

Vertika Pathak, Teresa Nolte, Elena Rama, Anne Rix, Seyed Mohammadali Dadfar, Vera Paefgen, Srinivas Banala, Eva Miriam Buhl, Marek Weiler, Volkmar Schulz, Twan Lammers, Fabian Kiessling

Biomaterials· Volume 275
Publisher page

Abstract

Microbubbles (MB) are used as ultrasound (US) contrast agents and can be efficiently targeted against markers of angiogenesis and inflammation. Due to their gas core, MB locally alter susceptibilities in magnetic resonance imaging (MRI), but unfortunately, the resulting contrast is low and not sufficient to generate powerful molecular MRI probes. Therefore, we investigated whether a potent molecular MR agent can be generated by encapsulating superparamagnetic iron oxide nanoparticles (SPION) in the polymeric shell of poly (n-butylcyanoacrylate) (PBCA) MB and targeted them against αvβ3 integrins on the angiogenic vasculature of 4T1 murine breast carcinomas. SPION-MB consist of an air core and a multi-layered polymeric shell enabling efficient entrapment of SPION. The mean size of SPION-MB was 1.61 ± 0.32 μm. Biotin-streptavidin coupling was employed to functionalize the SPION-MB with cyclic RGDfK (Arg-Gly-Asp) and RADfK (Arg-Ala-Asp) peptides. Cells incubated with RGD-SPION-MB showed enhanced transverse relaxation rates compared with SPION-MB and blocking αvβ3 integrin receptors with excess free cRGDfK significantly reduced RGD-SPION-MB binding. Due to the fast binding of RGD-SPION-MB in vivo, dynamic susceptibility contrast MRI was employed to track their retention in tumors in real-time. Higher retention of RGD-SPION-MB was observed compared with SPION-MB and RAD-SPION-MB. To corroborate our MRI results, molecular US was performed the following day using the destruction-replenishment method. Both imaging modalities consistently indicated higher retention of RGD-SPION-MB in angiogenic vessels compared with SPION-MB and RAD-SPION-MB. Competitive blocking experiments in mice further confirmed that the binding of RGD-SPION-MB to αvβ3 integrin receptors is specific. Overall, this study demonstrates that RGD-SPION-MB can be employed as molecular MR/US contrast agents and are capable of assessing the αvβ3 integrin expression in the neovasculature of malignant tumors.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ultrasound and Hyperthermia Applications · Photoacoustic and Ultrasonic Imaging · Nanoparticle-Based Drug Delivery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Global, regional, and national comparative risk assessment of 79 behavioural, environmental and occupational, and metabolic risks or clusters of risks, 1990–2015: a systematic analysis for the Global Burden of Disease Study 201510.1016/S0140-6736(16)31679-8 ↗
2. 2019
3. Tumor angiogenesis10.1056/NEJMra0706596 ↗
4. Tumor angiogenesis: past, present and the near future10.1093/carcin/21.3.505 ↗
5. Forty-year journey of angiogenesis translational research10.1126/scitranslmed.3003149 ↗
6. Clinical application of antiangiogenic therapy: microvessel density, what it does and doesn't tell us10.1093/jnci/94.12.883 ↗
7. Evaluation of tumor response after locoregional therapies in hepatocellular carcinoma: are response evaluation criteria in solid tumors reliable?10.1002/cncr.24050 ↗
8. Pseudoprogression and pseudoresponse: imaging challenges in the assessment of posttreatment glioma10.3174/ajnr.A2397 ↗
9. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)10.1016/j.ejca.2008.10.026 ↗
10. Imaging tumor angiogenesis: the road to clinical utility10.2214/AJR.12.8568 ↗
11. Functional imaging of cancer with emphasis on molecular techniques
12. Development of biologic markers of response and assessment of antiangiogenic activity in a clinical trial of human recombinant endostatin10.1200/JCO.2002.05.102 ↗
13. Molecular imaging can accelerate anti-angiogenic drug development and testing10.1038/ncponc0929 ↗
14. In situ validation of VEGFR-2 and αvß3 integrin as targets for breast lesion characterization10.1007/s10456-016-9499-4 ↗
15. Requirement of vascular integrin alpha v beta 3 for angiogenesis10.1126/science.7512751 ↗
16. MR molecular imaging and fluorescence microscopy for identification of activated tumor endothelium using a bimodal lipidic nanoparticle10.1096/fj.05-4145fje ↗
17. Squamous cell carcinoma xenografts: use of VEGFR2-targeted microbubbles for combined functional and molecular US to monitor antiangiogenic therapy effects10.1148/radiol.2015142899 ↗
18. Molecular and functional ultrasound imaging in differently aggressive breast cancer xenografts using two novel ultrasound contrast agents (BR55 and BR38)10.1007/s00330-011-2138-y ↗
19. Ultrasound molecular imaging: moving toward clinical translation10.1016/j.ejrad.2015.03.016 ↗
20. Ultrasound molecular imaging with BR55 in patients with breast and ovarian lesions: first-in-human results10.1200/JCO.2016.70.8594 ↗
21. Detection of tumor angiogenesis in vivo by αvβ3-targeted magnetic resonance imaging10.1038/nm0598-623 ↗
22. Imaging of angiogenesis10.1007/s10456-010-9178-9 ↗
23. Molecular magnetic resonance imaging with Gd (III)-based contrast agents: challenges and key advances10.1021/jacs.9b09149 ↗
24. Nanomedicine strategies for molecular targets with MRI and optical imaging10.4155/fmc.10.5 ↗
25. Challenges for molecular magnetic resonance imaging10.1021/cr100025t ↗
26. Science to practice: will contrast agents for molecular imaging of angiogenesis help overcome the limitations of functional vascular imaging?10.1148/radiol.13131094 ↗
27. Nanoparticles for imaging: top or flop?10.1148/radiol.14131520 ↗
28. Current limitations of molecular magnetic resonance imaging for tumors as evaluated with high-relaxivity CD105-specific iron oxide nanoparticles10.1097/RLI.0b013e31824c5a57 ↗
29. Specific targeting of tumor angiogenesis by RGD-conjugated ultrasmall superparamagnetic iron oxide particles using a clinical 1.5-T magnetic resonance scanner10.1158/0008-5472.CAN-06-1668 ↗
30. An approach to molecular imaging of atherosclerosis, thrombosis, and vascular inflammation using microparticles of iron oxide10.1016/j.atherosclerosis.2009.10.009 ↗
31. Molecular magnetic resonance imaging of angiogenesis in vivo using polyvalent cyclic RGD-iron oxide microparticle conjugates10.7150/thno.10319 ↗
32. Theranostic USPIO‐loaded microbubbles for mediating and monitoring blood‐brain barrier permeation10.1002/adfm.201401199 ↗
33. Iron oxide nanoparticle-containing microbubble composites as contrast agents for MR and ultrasound dual-modality imaging10.1016/j.biomaterials.2011.05.019 ↗
34. PBCA-based polymeric microbubbles for molecular imaging and drug delivery10.1016/j.jconrel.2017.03.006 ↗
35. Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance10.1186/s12951-020-0580-1 ↗
36. Polydopamine-mediated immobilization of multiple bioactive molecules for the development of functional vascular graft materials10.1016/j.biomaterials.2012.08.011 ↗
37. Rhodamine-loaded intercellular adhesion molecule–1-targeted microbubbles for dual-modality imaging under controlled shear stresses
38. Kuperman · 2000
39. Models and methods for analyzing DCE‐MRI: a review10.1118/1.4898202 ↗
40. Breast cancer screening with imaging: recommendations from the Society of Breast Imaging and the ACR on the use of mammography, breast MRI, breast ultrasound, and other technologies for the detection of clinically occult breast cancer10.1016/j.jacr.2009.09.022 ↗
41. A systematic review of the effectiveness of magnetic resonance imaging (MRI) as an addition to mammography and ultrasound in screening young women at high risk of breast cancer10.1016/j.ejca.2007.06.007 ↗
42. MRI–ultrasound fusion for guidance of targeted prostate biopsy10.1097/MOU.0b013e32835ad3ee ↗
43. Superparamagnetic iron oxide nanoparticle-embedded encapsulated microbubbles as dual contrast agents of magnetic resonance and ultrasound imaging10.1016/j.biomaterials.2009.03.051 ↗
44. Molecular imaging of inflammation in atherosclerosis with targeted ultrasound detection of vascular cell adhesion molecule-110.1161/CIRCULATIONAHA.106.684738 ↗
45. Molecular ultrasound imaging of junctional adhesion molecule a depicts acute alterations in blood flow and early endothelial dysregulation10.1161/ATVBAHA.117.309503 ↗
46. Characterization of different microbubbles in assisting focused ultrasound-induced blood-brain barrier opening
47. Bubble trouble: conquering microbubble limitations in contrast enhanced ultrasound imaging by nature-inspired ultrastable echogenic nanobubbles
48. The effect of lipid monolayer in-plane rigidity on in vivo microbubble circulation persistence10.1016/j.biomaterials.2013.05.053 ↗
49. Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery10.1146/annurev.bioeng.8.061505.095852 ↗
50. Targeting and modulation of liver myeloid immune cells by hard‐shell microbubbles10.1002/adbi.201800002 ↗
51. Microbubbles as a novel contrast agent for brain MRI10.1016/j.neuroimage.2009.02.037 ↗
52. MRI estimation of the arterial input function in mice10.1016/S1076-6332(03)00291-5 ↗
53. Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging10.1007/s00330-012-2418-1 ↗
54. Magnetic resonance fingerprinting10.1038/nature11971 ↗
55. Dynamic, simultaneous concentration mapping of multiple MRI contrast agents with dual contrast-magnetic resonance fingerprinting10.1038/s41598-019-56531-7 ↗