A transcatheter mitral valve clip with a central filler for mitral valve regurgitation
Source abstract
Abstract
Despite the advantages of transcatheter edge-to-edge repair (TEER) devices for treating mitral regurgitation, challenges such as difficulties in leaflet grasping and clip dislodgement remain in clinical practice. In this study, we present the first detailed disclosure of a novel transcatheter mitral valve clip, the DragonFly, highlighting its material composition, design features, and associated benefits. The valve clip is constructed of nickel-titanium alloy, stainless steel, cobalt-chromium alloy, and polyethylene terephthalate, incorporating adjustable arms, grippers, and a unique central filler. The central filler, made of nitinol, offers remarkable compressibility and shape recovery. The whole valve clip can endure over 400 million fatigue cycles and ensure a robust grasp on valve leaflets at varying angles. The clip presents sufficient grasping force to prevent valve dislodgement, and the adjustable design accommodates various patient anatomies. Comprehensive biocompatibility assessments confirmed adherence to ISO 10993 standards through in vitro and in vivo experiments, including large-animal studies. The results demonstrated that the valve clip successfully creates a stable double-orifice structure without negatively impacting cardiac hemodynamics and has good biocompatibility. Overall, the DragonFly valve clip constitutes a technological advancement in the field of minimally invasive interventions for mitral valve disease, offering more treatment options for high-risk patients.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Infective Endocarditis Diagnosis and Management · Cardiac and Coronary Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. Prosthetic heart valves for transcatheter aortic valve replacement
2. Chemical engineering of cell therapy for heart diseases10.1021/acs.accounts.9b00137 ↗
3. Recent development in tBiomed. Eng. Material.herapeutic cardiac patches10.3389/fcvm.2020.610364 ↗
4. Burden of valvular heart diseases: a population-based study10.1016/S0140-6736(06)69208-8 ↗
5. Quantitative determinants of the outcome of asymptomatic mitral regurgitation10.1056/NEJMoa041451 ↗
6. Surgical or transcatheter mitral valve intervention: complex disease requires complex decisions
7. A Canadian cost-effectiveness analysis of transcatheter mitral valve repair with the MitraClip system in high surgical risk patients with significant mitral regurgitation10.3111/13696998.2014.923892 ↗
8. Mitral clip–looking back and moving forward10.1097/HCO.0000000000000261 ↗
9. T. Feldman, D.D. Foster E Fau - Glower, S. Glower Dd Fau - Kar, M.J. Kar S Fau - Rinaldi, P.S. Rinaldi Mj Fau - Fail, R.W. Fail Ps Fau - Smalling, R. Smalling Rw Fau - Siegel, G.A. Siegel R Fau - Rose, E. Rose Ga Fau - Engeron, C. Engeron E Fau - Loghin, A. Loghin C Fau - Trento, E.R. Trento A Fau - Skipper, T. Skipper Er Fau - Fudge, G.V. Fudge T Fau - Letsou, J.M. Letsou Gv Fau - Massaro, L. Massaro Jm Fau - Mauri, L. Mauri, Percutaneous repair or surgery for mitral regurgitation, N. Engl. J. Med. 364(15) 1395-1406.10.1056/NEJMoa1009355 ↗
10. Clinical pathway for transcatheter mitral rim-to-rim repair in China (2022 edition)
11. ESC/EACTS Guidelines for the management of valvular heart disease10.1093/eurheartj/ehab395 ↗
12. AHA/ACC guideline for the diagnosis and treatment of patients with hypertrophic cardiomyopathy: a report of the American college of cardiology/American heart association joint committee on clinical practice guidelines10.1016/j.jtcvs.2021.04.001 ↗
13. MitraClip: a review of its current status and future perspectives10.1007/s12928-022-00898-4 ↗
14. Real-World outcomes of fourth-generation mitral transcatheter repair10.1016/j.jcin.2023.05.013 ↗
15. The PASCAL transcatheter valve repair system: a user's guide
16. The EVEREST II Trial: design and rationale for a randomized study of the evalve mitraclip system compared with mitral valve surgery for mitral regurgitation10.1016/j.ahj.2010.04.009 ↗
17. AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American college of cardiology/American heart association task force on clinical practice guidelines10.1161/CIR.0000000000000503 ↗
18. 1-Year outcomes with a fourth-generation mitral TEER device: maturity comes with experience10.1016/j.jcin.2023.09.035 ↗
19. Initial experience with commercial transcatheter mitral valve repair in the United States10.1016/j.jacc.2015.12.054 ↗
20. A meta-analysis of MitraClip system versus surgery for treatment of severe mitral regurgitation
21. Adverse events following transcatheter edge-to-edge repair (TEER) using MitraClip: lessons learned from the manufacturer and user facility device experience (MAUDE) registry10.1016/j.carrev.2021.09.007 ↗
22. Risk and outcomes of complications during and after MitraClip implantation: experience in 828 patients from the German TRAnscatheter mitral valve interventions (TRAMI) registry
23. Temporal trends and outcomes of transcatheter mitral valve repair and surgical mitral valve intervention10.1016/j.carrev.2020.05.021 ↗
24. Incidence, clinical correlates, timing, and consequences of acute thrombus formation in patients undergoing the MitraClip procedure10.33963/KP.15056 ↗
25. Complications following MitraClip implantation10.1007/s11886-021-01553-9 ↗
26. Percutaneous mitral valve interventions in the real world: early and 1-year results from the ACCESS-EU, a prospective, multicenter, nonrandomized post-approval study of the MitraClip therapy in Europe10.1016/j.jacc.2013.02.094 ↗
27. Edge-to-Edge mitral valve repair with extended clip arms: early experience from a multicenter observational study10.1016/j.jcin.2019.03.023 ↗
28. A new age for transcatheter mitral valve repair: the complexity of choice10.1016/j.jcin.2020.07.023 ↗
29. Attachment of a migrated MitraClip to the left ventricular apex: a novel case report10.1111/echo.14573 ↗
30. Percutaneous mitral valve edge-to-edge repair: in-hospital results and 1-year follow-up of 628 patients of the 2011–2012 pilot European sentinel registry10.1016/j.jacc.2014.06.1166 ↗
31. Left atrial pressure is associated with iatrogenic atrial septal defect after mitral valve clip10.1136/heartjnl-2018-313839 ↗
32. Transcatheter edge-to-edge mitral valve repair with the MitraClip G4 system10.1016/j.jcin.2020.06.053 ↗
33. 2012 · 28
34. ISO 10993-10-2021 Biological Evaluation of Medical Devices — Part 10 Tests for Skin Sensitization.
35. ISO 10993-11-2017 Biological Evaluation of Medical Devices — Part 11 Tests for Systemic Toxicity.
36. Abstract 13429: echocardiographic predictors of mitral transvalvular gradients after mitraclip insertion
37. Elevated mitral valve pressure gradient after MitraClip implantation deteriorates long-term outcome in patients with severe mitral regurgitation and severe heart failure10.1016/j.jcin.2016.12.280 ↗
38. Transcatheter mitral valve therapy in the United States: a report from the STS/ACC TVT registry10.1016/j.athoracsur.2021.07.030 ↗
39. Edge-to-Edge mitral repair10.1161/hc37t1.094523 ↗
40. ISO 5910-2018 Cardiovascular Implants and Extracorporeal Systems - Cardiac Valve Repair Devices.
41. ISO 10993-5-2009 Biological Evaluation of Medical Devices — Part 5 Tests for in Vitro Cytotoxicity.
42. ISO 10993-4-2017 Biological Evaluation of Medical Devices — Part 4 Selection of Tests for Interactions with Blood.
43. Preparation and properties of cellulose acetate graft copolymer-coated adsorbent resin for hemoperfusion device10.1002/app.53895 ↗
44. Pathological healing response of explanted MitraClip devices10.1161/CIRCULATIONAHA.110.978130 ↗
45. Oxide layer formation, corrosion, and biocompatibility of nitinol cardiovascular devices10.1007/s40830-022-00365-2 ↗
46. Ion release and surface characterization of nanostructured nitinol during long-term testing10.3390/nano9111569 ↗
47. ISO 10993-6 2016 Biological Evaluation of Medical Devices — Part 6 Tests for Local Effects after Implantation.
48. Endovascular edge-to-edge mitral valve repair10.1161/01.CIR.0000096052.78331.CA ↗
49. Cardiovascular function of modern pigs does not comply with allometric scaling laws10.1038/s41598-017-18775-z ↗
50. Cardiac dimensions and hemodynamics in healthy juvenile Landrace swine10.1186/s12947-023-00321-9 ↗
51. Pathological healing response of explanted MitraClip devices10.1161/CIRCULATIONAHA.110.978130 ↗
52. Mitral repair with the Evalve MitraClip device: histopathologic findings in the porcine model10.1016/j.carpath.2008.07.001 ↗
53. Passivation protein-adhesion platform promoting stent reendothelialization using two-electron-assisted oxidation of polyphenols
54. A multi-in-one strategy with glucose-triggered long-term antithrombogenicity and sequentially enhanced endothelialization for biological valve leaflets10.1016/j.biomaterials.2021.120981 ↗
55. Endothelialization of cardiovascular devices10.1016/j.actbio.2019.08.042 ↗
56. First-in-Human study of the novel transcatheter mitral valve repair system for mitral regurgitation
57. Transcatheter mitral valve repair in a high-surgical risk patient with severe degenerative mitral regurgitation using the novel DragonFly™ Transcatheter Repair device—first in man implantation in China
58. A modified Carpentier classification in transcatheter edge-to-edge repair for mitral regurgitation
59. Safety and efficacy of the DragonFly system for transcatheter valve repair of degenerative mitral regurgitation: one-year results of the DRAGONFLY-DMR trial
60. Mitral valve transcatheter edge-to-edge repair
61. PASCAL repair system for patients with mitral regurgitation: a systematic review10.1016/j.ijcard.2023.01.026 ↗
62. 1-Year outcomes from the CLASP IID randomized trial for degenerative mitral regurgitation10.1016/j.jcin.2023.10.002 ↗
63. Early outcomes of 2 mitral valve transcatheter leaflet approximation devices10.1016/j.jcin.2022.10.008 ↗
64. Efficacy determinants of transcatheter edge-to-edge mitral valve repair