journal article·2000-10

Structural response and relative strength of a laminated composite hip prosthesis: effects of functional activity

S Srinivasan, J.R de Andrade, S.B Biggers Jr, R.A Latour Jr

Biomaterials· Volume 21· Issue 19
Publisher page

Abstract

To obtain a better appreciation for the structural performance of a laminated composite hip prosthesis (CP), we examined in situ prosthesis structural response and relative strengths as a function of walking and stair climbing using our previously developed analysis guidelines. Accordingly, we examined overall prosthesis structural response utilizing a global continuum level modeling approach and prosthesis relative strengths using a local microstructural (or ply-level) modeling approach. As a reference and control, we examined the structural performance of the intact natural femur (NAT) and a titanium alloy (Ti) based hip prosthesis. In terms of the overall structural response, i.e., the femur/prosthesis deformational response, stem/bone interfacial stress transfer, and calcar strain energy density restored, the performance of the CP prosthesis was moderately improved over that of the control Ti prosthesis and better approximates the NAT response. In terms of relative strength, we found that the neck of the CP prosthesis failed for all activities with the exception of the mid-stance phase of level walking. However, the prosthesis appears to have sufficient relative strength for function at positions distal to the neck of the prosthesis. While these results dampen enthusiasm for consideration of laminated composite hip prostheses designed with a shape based on a metal alloy implant, they indirectly support consideration of alternate hip prosthesis structural designs such as using a better supported prosthesis neck or utilizing metal/composite hybrid constructions. Importantly, our simulation and analysis approach could be utilized in the design of other laminated composite biomedical structural components.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ecology and biodiversity studies · Fish Ecology and Management Studies · Wildlife Ecology and Conservation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. The first 32 years of total hip arthroplasty: one surgeon's perspective10.1097/00003086-199201000-00003 ↗
2. Lessons of 30 years of total hip arthroplasty10.1097/00003086-199201000-00004 ↗
3. The challenge and opportunity for composites in structural orthopaedic applications10.1520/CTR10436J ↗
4. Koeneman JB, Overland MK, Longo III JA. Design, analysis, and material considerations of a composite material artificial hip implant. In: Wise DL, Trantolo DJ, Altobelli DE, Yaszemski MJ, Gresser JD, Schwartz ER, editors. Encyclopedic handbook of biomaterials and bioengineering, Part B: applications. New York: Marcel Dekker Inc. 1995. p. 171–87.
5. Spector M, Zapatka-Taylor S, Hsu HP, Cheal EJ, Sledge CB, Reilly DT. Histological response to composite stems in dogs. Proceedings of the Fourth World Biomaterials Congress, 1992. p. 263.
6. Early failure of a carbon-fiber composite femoral component10.1016/S0883-5403(97)90038-3 ↗
7. Trentacosta JD, Hastings RS, Marcolongo M. Mechanical performance of a hybrid composite hip stem in a lipid environment: residual strength and microscopic analysis after fatigue cycling. Transactions of the Annual Meeting, Society for Biomaterials and the International Biomaterials Symposium, vol. 2. 1996. p. 82.
8. Mechanical simulation of composite hip stems10.1016/S1350-4533(97)00008-8 ↗
9. Finite element and experimental test results for PEEK composite intramedullary implants
10. McMillin CR, Brantigan JW. Design of CFRP lumbar/thoracic stackable spine fusion cages. Proceedings of the International SAMPE Symposium and Exhibition, vol. 38. 1993. p. 582–90.
11. Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis10.1002/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L ↗
12. The application of new composite materials for total joint arthroplasty
13. Analysis of composite structures using the 3-D global/3-D local method10.1177/073168449701600406 ↗
14. Global-local methodologies and their application to nonlinear analysis10.1016/0168-874X(86)90020-X ↗
16. 3-D global/local analysis of composite hip prostheses—A model for multiscale structural analysis10.1016/S0263-8223(99)00020-3 ↗
17. Enrichment of finite elements with numerical solutions for singular stress fields10.1002/(SICI)1097-0207(19970730)40:14<2693::AID-NME190>3.0.CO;2-X ↗
18. The anatomic basis of femoral component design10.1097/00003086-198810000-00015 ↗
19. Image processing and neural network based analysis of cell kinetic behavior
20. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
21. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty10.1002/jor.1100100314 ↗
22. 3-dimensional stress analysis of in situ FRP composite femoral components for total hip arthroplasty
23. Failure analysis of composite laminates with free edge10.1520/CTR10184J ↗
24. Quadratic stress criterion for initiation of delamination10.1177/002199838802201205 ↗
25. Nonlinear finite element analysis of interface conditions in porous coated hip endoprostheses10.1016/0021-9290(88)90224-2 ↗
26. Identifying global/local interface boundaries using an objective search method10.1002/(SICI)1097-0207(19960315)39:5<805::AID-NME883>3.0.CO;2-A ↗
27. Thigh pain after cementless hip arthroplasty10.1302/0301-620X.74B1.1732268 ↗
28. Compressive postbuckling response of stiffness tailored composite plates10.1177/073168449401300903 ↗
29. Aeroelastic tailoring—Theory, practice, and promise10.2514/3.45260 ↗
30. Adaptive bone-remodeling theory applied to prosthetic-design analysis10.1016/0021-9290(87)90030-3 ↗
31. Strain gradients correlate with sites of periosteal bone formation10.1359/jbmr.1997.12.6.982 ↗
32. Strain gradients correlate with sites of exercise-induced bone-forming surfaces in the adult skeleton10.1359/jbmr.1997.12.10.1737 ↗
33. Composite technology in load-bearing orthopaedic implants10.1016/S0142-9612(97)00217-2 ↗
34. Moore DR, Robinson IM, Zahlan N. Mechanical properties for design and analysis of carbon fiber reinforced PEEK composite structures. Proceedings of the European SAMPE Symposium 1989.
35. Thermoplastics composites handbook. Tempe: ICI Fiberite Publication, 1992.
36. Long-term compressive property durability of carbon fiber-reinforced polyetheretherketone composite in physiological saline10.1016/0142-9612(96)81415-3 ↗
37. D'Ariano MD, Latour Jr RA, Kennedy JM, Schutte Jr HD, Friedman RJ. Long term shear strength durability of CF/PEEK composite in physiologic saline. Transactions of the Annual Meeting, Society for Biomaterials, 1994. p. 184.