journal article·2011-12

The influence of surface topography of a porous perfluoropolyether polymer on corneal epithelial tissue growth and adhesion

Margaret D.M. Evans, Hassan Chaouk, John S. Wilkie, Beatrice A. Dalton, Sarah Taylor, Ruo Zhong Xie, Timothy C. Hughes, Graham Johnson, Gail A. McFarland, Hans H. Griesser, John G. Steele, Gordon F. Meijs, Deborah F. Sweeney, Keith M. McLean

Biomaterials· Volume 32· Issue 34
Publisher page

Abstract

Design principles for corneal implants are challenging and include permeability which inherently involves pore openings on the polymer surface. These topographical cues can be significant to a successful clinical outcome where a stratified epithelium is needed over the device surface, such as with a corneal onlay or corneal repair material. The impact of polymer surface topography on the growth and adhesion of corneal epithelial tissue was assessed using porous perfluoropolyether membranes with a range of surface topography. Surfaces were characterised by AFM and XPS, and the permeability and water content of membranes was measured. Biological testing of membranes involved a 21-day in vitro tissue assay to evaluate migration, stratification and adhesion of corneal epithelium. Similar parameters were monitored in vivo by surgically implanting membranes into feline corneas for up to 5 months. Data showed optimal growth and adhesion of epithelial tissue in vitro when polymer surface features were below a 150 nm RMS value. Normal processes of tissue growth and adhesion were disrupted when RMS values approached 300 nm. Data from the in vivo study confirmed these findings. Together, outcomes demonstrated the importance of surface topography in the design of implantable devices that depend on functional epithelial cover.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal Surgery and Treatments · Corneal surgery and disorders · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Design principles of synthetic inlays and onlays
2. Synthetic corneal implants
3. Meijs GF, Laycock BG, Griffiths MC, Cheong E, Steele JG, Johnson G. Cell growth substrate polymer. US Patent No. 5994133, 1996.
4. Chaouk H, Meijs GF, Laycock BG. Process for manufacture of a porous polymer from a mixture. US Patent No. 6015609, 2000.
5. Approaches to improving the biocompatibility of porous perfluoropolyethers for ophthalmic applications10.1016/j.biomaterials.2005.08.005 ↗
6. A perfluoropolyether corneal inlay for the correction of refractive error10.1016/j.biomaterials.2011.01.047 ↗
7. A new hypothesis of contact guidance in tissue cells10.1016/0014-4827(76)90405-5 ↗
8. Michael Abercrombie: the pioneer ethologist of cells10.1016/S0962-8924(97)01213-0 ↗
9. Interactions of epithelial cells with foreign surfaces
10. Topographical control of cells10.1016/S0142-9612(97)00144-0 ↗
11. Reactions of cells to topography10.1163/156856298X00415 ↗
12. Cellular response to low adhesion nanotopographies
13. Role of materials surface topography on mammalian cell response10.1179/1743280411Y.0000000001 ↗
14. Epithelial contact guidance on well-defined micro- and nanostructured substrates10.1242/jcs.00383 ↗
15. Cell behaviour on lithographically defined nanostructured substrates
16. Nanoscale topography modulates corneal epithelial cell migration10.1002/jbm.a.30467 ↗
17. Sub-micron and nanoscale feature depth modulates alignment of stromal fibroblasts and corneal epithelial cells in serum-rich and serum-free media10.1002/jbm.a.31519 ↗
18. Effects of a grooved epoxy substratum on epithelial cell behaviour in vitro and in vivo10.1002/jbm.820220603 ↗
19. Titanium-coated micromachined grooves of different dimensions affect epithelial and connective tissue cells differently in vivo10.1002/jbm.820240906 ↗
20. A light and electron microscopic study of the effects of surface topography on the behaviour of cells attached to titanium-coated percutaneous implants10.1002/jbm.820250310 ↗
21. The role of connective tissue in inhibiting epithelial downgrowth on titanium-coated percutaneous implants10.1002/jbm.820260407 ↗
22. Microgrooved subcutaneous implants in the goat10.1002/(SICI)1097-4636(19981215)42:4<634::AID-JBM21>3.0.CO;2-O ↗
23. The effects of the surface topography of micromachined titanium substrata on cell behaviour in vitro and in vivo10.1115/1.2798042 ↗
24. Soft-tissue response to silicone and poly-L-lactic acid implants with a periodic or random surface micropattern10.1002/jbm.10170 ↗
25. Effect of microtextured surfaces on the performance of percutaneous devices10.1002/jbm.a.30337 ↗
26. Wound healing in the cornea of the chick embryo10.1016/0012-1606(76)90121-4 ↗
27. Surface topography can interfere with epithelial tissue migration10.1002/(SICI)1097-4636(199811)42:2<245::AID-JBM9>3.0.CO;2-P ↗
28. Modulation of corneal epithelial stratification by polymer surface topography10.1002/(SICI)1097-4636(19990615)45:4<384::AID-JBM14>3.0.CO;2-O ↗
29. Persistent adhesion of epithelial tissue is sensitive to polymer topography10.1002/(SICI)1097-4636(19990915)46:4<485::AID-JBM6>3.0.CO;2-F ↗
30. Polymer design for corneal epithelial tissue adhesion: pore density10.1002/jbm.a.10341 ↗
31. New porous perfluoropolyether membranes10.1002/app.1270 ↗
32. Nutritional requirements of the corneal epithelium and anterior stroma: clinical findings
33. Quantitation of rabbit corneal epithelial cell outgrowth on polymeric substrates in vitro
34. Epithelialization of a synthetic polymer in the feline cornea - a preliminary study
35. Progress in the development of a synthetic corneal onlay
36. Two-year preclinical testing of perfluoropolyether as a corneal inlay10.1167/iovs.05-0872 ↗
37. Material properties and clinical results of a hydrogel intracorneal implant
38. Hydrolysis of a neutral hydrogel and biomolecule attachment to increase cell adhesion and migration
39. Nanoscale topography of the corneal epithelial basement membrane and Descemet’s membrane of the human10.1097/00003226-200001000-00012 ↗