Optimization of stress distribution of bone-implant interface (BII)
Source abstract
Abstract
Many studies have found that the threshold of occlusal force tolerated by titanium-based implants is significantly lower than that of natural teeth due to differences in biomechanical mechanisms. Therefore, implants are considered to be susceptible to occlusal trauma. In clinical practice, many implants have shown satisfactory biocompatibility, but the balance between biomechanics and biofunction remains a huge clinical challenge. This paper comprehensively analyzes and summarizes various stress distribution optimization methods to explore strategies for improving the resistance of the implants to adverse stress. Improving stress resistance reduces occlusal trauma and shortens the gap between implants and natural teeth in occlusal function. The study found that: 1) specific implant-abutment connection design can change the force transfer efficiency and force conduction direction of the load at the BII; 2) reasonable implant surface structure and morphological character design can promote osseointegration, maintain alveolar bone height, and reduce the maximum effective stress at the BII; and 3) the elastic modulus of implants matched to surrounding bone tissue can reduce the stress shielding, resulting in a more uniform stress distribution at the BII. This study concluded that the core BII stress distribution optimization lies in increasing the stress distribution area and reducing the local stress peak value at the BII. This improves the biomechanical adaptability of the implants, increasing their long-term survival rate. • The biomechanical compatibility of dental implants has not reached a satisfactory level. • Reasonable stress distribution pattern can improve the its biomechanical compatibility. • Contact point and contact force vector are essential factors affecting stress distribution. • The core of optimizing BII stress distribution is to increase stress distribution area.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Vertical soft tissue thickness
2. Damping and mechanical behavior of metal-ceramic composites applied to novel dental restorative systems10.1016/j.jmbbm.2018.09.046 ↗
3. Relationships of stresses on alveolar bone and abutment of dental implant from various bite forces by three-dimensional finite element analysis10.1155/2020/7539628 ↗
4. The soft tissue barrier at implants and teeth10.1034/j.1600-0501.1991.020206.x ↗
5. The barrier between the keratinized mucosa and the dental implant. An experimental study in the dog10.1034/j.1600-051X.1999.261005.x ↗
6. Molecular and cell biology of the gingiva10.1034/j.1600-0757.2000.2240103.x ↗
7. Soft tissue sealing around dental implants based on histological interpretation10.1016/j.jpor.2015.07.001 ↗
8. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures10.1590/1678-775720150297 ↗
9. Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps10.1111/j.1365-2842.2011.02217.x ↗
10. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models10.1902/jop.2014.140107 ↗
11. Effect of bone quality and bone loss level around internal and external connection implants: a finite element analysis study10.1016/j.prosdent.2020.06.029 ↗
12. Influence of abutment design on stress distribution in narrow implants with marginal bone loss: a finite element analysis10.11607/jomi.8554 ↗
13. Effect of peri-implant bone resorption on mechanical stress in the implant body: in vivo measured load-based finite element analysis10.1111/joor.13097 ↗
14. Effect of different implant designs on strain and stress distribution under non-axial loading: a three-dimensional finite element analysis10.3390/ijerph17134738 ↗
15. The effect of tapered and cylindrical implants on stress distribution in different bone qualities: a finite element analysis10.11607/jomi.7513 ↗
16. A 2003 update of bone physiology and Wolff's law for clinicians
17. Wolff's law and bone's structural adaptations to mechanical usage: an overview for clinicians
18. A 2003 update of bone physiology and Wolff's law
19. Effects of mechanical repetitive load on bone quality around implants in rat maxillae10.1371/journal.pone.0189893 ↗
20. Effect of different biocompatible implant materials on the mechanical stability of dental implants under excessive oblique load10.1111/cid.12858 ↗
21. Induction of osteopenia during experimental tooth movement in the rat: alveolar bone remodelling and the mechanostat theory10.1093/ejo/cjp032 ↗
22. A histological and biomechanical study of bone stress and bone remodeling around immediately loaded implants10.1007/s11427-014-4657-7 ↗
23. Investigation of porous cells interface on elastic property of orthopedic implants: numerical and experimental studies10.1016/j.jmbbm.2021.104595 ↗
24. Rotating hinge knee causes lower bone-implant interface stress compared to constrained condylar knee replacement10.1007/s00167-018-5054-8 ↗
25. Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis10.1007/s11517-021-02342-w ↗
26. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study10.1016/j.prosdent.2017.03.008 ↗
27. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis10.1016/j.msec.2014.09.005 ↗
28. Stress distribution with extra-short implants in an angled frictional system: a finite element analysis study
29. The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses10.1016/j.msec.2014.01.013 ↗
30. Influence of crown-to-implant ratio on stress around single short-wide implants: a photoelastic stress analysis10.1111/jopr.12171 ↗
31. Stress analysis in bone tissue around single implants with different diameters and veneering materials: a 3-D finite element study10.1016/j.msec.2013.07.027 ↗
32. Finite element analysis and experimental evaluation on stress distribution and sensitivity of dental implants to assess optimum length and thread pitch10.1016/j.cmpb.2019.105258 ↗
33. Biomechanical analysis of different implant-abutments interfaces in different bone types: an in silico analysis10.1016/j.msec.2018.05.012 ↗
34. Viability of maxillary single crowns supported by 4-mm short implants: a finite element study10.11607/jomi.6784 ↗
35. Analysis of the biomechanical behavior of short implants: the photo-elasticity method10.1016/j.msec.2015.05.024 ↗
36. Influence of implant length and diameter, bicortical anchorage, and sinus augmentation on bone stress distribution: three-dimensional finite element analysis10.11607/jomi.4217 ↗
37. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: a photoelastic stress analysis study10.1016/j.prosdent.2015.08.021 ↗
38. Biomechanical effects of implant number and diameter on stress distributions in maxillary implant-supported overdentures10.1016/j.prosdent.2017.03.016 ↗
39. Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture10.1016/j.compbiomed.2014.08.018 ↗
40. Occlusal geometrical considerations in all-ceramic pre-molar crown failure testing10.1016/j.dental.2011.08.005 ↗
41. The effect of different occlusal contact situations on peri-implant bone stress - a contact finite element analysis of indirect axial loading10.1016/j.msec.2019.01.104 ↗
42. Biomechanical study of the development of long bones: finite element structure synthesis of the human second proximal phalanx under growth conditions10.1002/ar.24006 ↗
43. Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: a finite element analysis study10.1016/j.prosdent.2020.09.058 ↗
44. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: a finite element analysis study
45. A comparative 3D finite element computational study of three connections10.3390/ma12193135 ↗
46. Finite element analysis on influence of implant surface treatments, connection and bone types10.1016/j.msec.2016.02.061 ↗
47. Three interfaces of the dental implant system and their clinical effects on hard and soft tissues10.1039/D1MH01621K ↗
48. Biomechanical three-dimensional finite element analysis of single implant-supported prostheses in the anterior maxilla, with different surgical techniques and implant types10.11607/jomi.5472 ↗
49. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis10.1016/j.prosdent.2015.04.018 ↗
50. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis10.1902/jop.2013.120713 ↗
51. In vitro differences of stress concentrations for internal and external hex implant–abutment connections: a short communication10.1111/j.1365-2842.2006.01545.x ↗
52. Evaluation of microgap with three-dimensional X-ray microtomography: internal hexagon versus cone morse10.1097/SCS.0000000000002563 ↗
53. Sealing capability of implant-abutment junction under cyclic loading: a toluidine blue in vitro study
54. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design10.1034/j.1600-0501.1997.080407.x ↗
55. Effects of different abutment material and surgical insertion torque on the marginal adaptation of an internal conical interface: an in vitro study10.1016/j.jpor.2014.05.004 ↗
56. Biomechanical analysis on platform switching: is there any biomechanical rationale?10.1111/j.1600-0501.2007.01398.x ↗
57. A comparative analysis on two types of oral implants, bone-level and tissue-level, with different cantilever lengths of fixed prosthesis10.1111/jopr.12388 ↗
58. Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads10.1007/s10266-016-0237-6 ↗
59. Effect of platform switching on peri-implant bone: a 3D finite element analysis10.1016/j.prosdent.2018.08.011 ↗
60. Influence of microthreads and platform switching on stress distribution in bone using angled abutments10.1016/j.jpor.2012.02.002 ↗
61. Regular and platform switching: bone stress analysis varying implant type10.1111/j.1532-849X.2011.00801.x ↗
62. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses10.1016/j.msec.2016.09.062 ↗
63. Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: an in vitro laboratory and three-dimensional finite element analysis10.1016/j.dental.2012.05.004 ↗
64. The effect of platform switching on stress distribution in implants and periimplant bone studied by nonlinear finite element analysis10.1016/j.prosdent.2014.04.017 ↗
65. Evaluation of the accuracy and stress distribution of 3-unit implant supported prostheses obtained by different manufacturing methods10.1016/j.msec.2019.03.059 ↗
66. The effect of platform switching on stress in peri-implant bone in a condition of marginal bone resorption: a three-dimensional finite element analysis10.11607/jomi.2965 ↗
67. Understanding and controlling the bone-implant interface10.1016/S0142-9612(99)00160-X ↗
68. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces10.1002/jbm.a.30518 ↗
69. Influence of nanoporous titanium niobium alloy surfaces produced via hydrogen peroxide oxidative etching on the osteogenic differentiation of human mesenchymal stromal cells10.1016/j.msec.2019.01.023 ↗
70. Design and optimization of the oriented groove on the hip implant surface to promote bone microstructure integrity10.1016/j.bone.2012.11.005 ↗
71. Enhanced osseointegration of hierarchically structured Ti implant with electrically bioactive SnO2-TiO2 bilayered surface10.1021/acsami.8b10928 ↗
72. Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant10.1016/j.jmbbm.2017.11.042 ↗
73. Effect of surface treatment on stress distribution in immediately loaded dental implants–a 3D finite element analysis10.1016/j.dental.2014.01.012 ↗
74. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits10.1002/jbm.820291009 ↗
75. Early loading of fluoridated implants placed in fresh extraction sockets and healed bone: a 3- to 5-year clinical and radiographic follow-up study of 39 consecutive patients10.1111/cid.12210 ↗
76. Early and immediate loading of titanium implants with fluoride-modified surfaces: results of 5-year prospective study10.1111/j.1600-0501.2010.02123.x ↗
77. Histomorphometry and bone mechanical property evolution around different implant systems at early healing stages: an experimental study in dogs10.1097/ID.0b013e31829f1f4b ↗
78. In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V alloy10.1002/jbm.b.32899 ↗
79. The effect of the DLTIDDSYWYRI motif of the human laminin alpha2 chain on implant osseointegration10.1016/j.biomaterials.2013.02.023 ↗
80. Tapping basement membrane motifs: oral junctional epithelium for surface-mediated soft tissue attachment to prevent failure of percutaneous devices10.1016/j.actbio.2021.12.030 ↗
81. Biological responses to the transitional area of dental implants: material- and structure-dependent responses of peri-implant tissue to abutments10.3390/ma13010072 ↗
82. Effect of dental implant diameter on fatigue performance. Part II: failure analysis10.1111/j.1708-8208.2012.00476.x ↗
83. Biomechanics and peri-implantitis: the effect of a subcrestal wing-thread to decrease alveolar crestal bone strain. theory, finite element analysis, and clinical application10.11607/jomi.te63 ↗
84. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant10.1902/jop.2010.100237 ↗
85. Optimized dental implant fixture design for the desirable stress distribution in the surrounding bone region: a biomechanical analysis10.3390/ma12172749 ↗
86. Evaluation of bone stimulation by different designs of microthreaded implants in enhancing osseointegration: an in vivo animal study supported by a numerical analysis10.1111/cid.12577 ↗
87. Influence of micro threads alteration on osseointegration and primary stability of implants: an FEA and in vivo analysis in rabbits10.1111/cid.12143 ↗
88. Influence of bone quality on the mechanical interaction between implant and bone: a finite element analysis10.1016/j.jdent.2019.06.008 ↗
89. Three-dimensional finite element analysis of the effect of endosteal implants with different macro designs on stress distribution in different bone qualities10.11607/jomi.7058 ↗
90. Evaluation of design parameters of osseointegrated dental implants using finite element analysis10.1046/j.1365-2842.2002.00891.x ↗
91. Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area10.1007/s00784-011-0517-z ↗
92. Customized root-analogue implants: a review on outcomes from clinical trials and case reports10.3390/ma14092296 ↗
93. Effect of porous microstructures on the biomechanical characteristics of a root analogue implant: an animal study and a finite element analysis10.1021/acsbiomaterials.0c01096 ↗
94. In silico evaluation of the stress fields on the cortical bone surrounding dental implants: comparing root-analogue and screwed implants10.1016/j.jmbbm.2020.103667 ↗
95. New Zr-Ti-Nb alloy for medical application: development, chemical and mechanical properties, and biocompatibility10.3390/ma13061306 ↗
96. Effects of implant neck design on primary stability and overload in a type IV mandibular bone10.1002/cnm.2653 ↗
97. Interaction of bone-dental implant with new ultra low modulus alloy using a numerical approach10.1016/j.msec.2014.01.048 ↗
98. Microstructure, mechanical properties and osseointegration ability of Ta–20Zr alloy used as dental implant material10.1088/1748-605X/ac6b05 ↗
99. In vitro evaluation of material dependent force damping behavior of implant-supported restorations using different CAD-CAM materials and luting conditions10.1016/j.prosdent.2021.03.016 ↗
100. Influence of PEEK coating on hip implant stress shielding: a finite element analysis10.1155/2016/6183679 ↗