Coupled benefits of nanotopography and titania surface chemistry in fostering endothelialization and reducing in-stent restenosis in coronary stents
Source abstract
Abstract
Recent advances in coronary stents have all been distinctively focused towards directing re-endothelialization with minimal in-stent restenosis, potentially via alterations in surface topographical cues, for augmenting the efficacy of vascular implants. This perspective was proven by our group utilizing a simple and easily scalable nanosurface modification strategy on metallic stents devoid of any drugs or polymers. In the present work, we explore the impact of surface characteristics in modulating this cell response in-vitro and in-vivo, using titania coated cobalt-chromium (CC) stents, with and without nanotopography, in comparison to commercial controls. Interestingly, titania nanotopography facilitated a preferential cell response in-vitro as against the titania coated and bare CC surfaces, which can be attributed to surface topography, hydrophilicity, and roughness. This in turn altered the cellular adhesion, proliferation and focal contact formations of endothelial and smooth muscle cells. We also demonstrate that titania nanotexturing plays a pivotal role in fostering rapid re-endothelialization with minimal neointimal hyperplasia, leading to excellent in-vivo patency of CC stents post 8 weeks implantation in rabbit iliac arteries, in comparison to bare CC, nano-less titania coated CC, and commercial drug-eluting stents (CC DES), without administering antiplatelet agents. This exciting result for the drug and polymer-free titania nanotextured stents, in the absence of platelet therapy, reveals the possibility of proposing an alternative to clinical DES for coronary stenting.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Aortic aneurysm repair treatments · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (77)
Show source-provided references
1. Recent advances in manufacturing innovative stents10.3390/pharmaceutics12040349 ↗
2. Gold-coated NIR stents in porcine coronary arteries10.1161/01.CIR.103.3.429 ↗
3. Windecker · 2006 · Vol. 2
4. The adhesion and clinical application of titanium oxide film on a 316 L vascular stent
5. Improving hemocompatibility and accelerating endothelialization of vascular stents by a copper-titanium film
6. Application of diamond-like-carbon coating to a coronary artery drug-eluting stent10.2494/photopolymer.20.221 ↗
7. In vivo biocompatibility of a plasma-activated, coronary stent coating10.1016/j.biomaterials.2012.07.059 ↗
8. Satzl · 2007 · Vol. 42
9. Reduction of late in-stent stenosis in a porcine coronary artery model by cobalt chromium stents with a nanocoat of polyphosphazene (Polyzene-F)10.1007/s00270-008-9392-7 ↗
10. Preventive effects of the heparin-coated stent on restenosis in the porcine model
11. Functionalized CD133 antibody coated stent surface simultaneously promotes EPCs adhesion and inhibits smooth muscle cell Proliferation–A novel approach to prevent in-stent restenosis10.1016/j.colsurfb.2018.11.061 ↗
12. Late endothelial progenitor cell-capture stents with CD146 antibody and nanostructure reduce in-stent restenosis and thrombosis10.1016/j.actbio.2020.05.011 ↗
13. Mechanical and physio-biological properties of peptide-coated stent for re-endothelialization10.1186/s40824-020-0182-x ↗
14. Comparison between basic and inverse dual drug and peptide-coated stents in a porcine restenosis model
15. Stent wars: coated stents strike Back10.1016/j.jcin.2020.05.017 ↗
16. Titanium-nitride-Oxide–Coated versus everolimus-eluting stents in acute coronary syndrome: the randomized TIDES-ACS trial10.1016/j.jcin.2020.04.021 ↗
17. Long-term clinical outcome of titanium-nitride-oxide-coated stents versus everolimus-eluting stents in acute coronary syndrome: final report of the BASE ACS trial10.1016/j.ijcard.2016.07.267 ↗
18. Enhancing stent effectiveness with nanofeatures10.14797/mdcj-12-3-163 ↗
19. 1-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single De novo coronary lesions. The VESTASYNC I trial10.1016/j.jcin.2009.02.009 ↗
20. Ribamar Costa · 2008
21. Clinical, angiographic, and intravascular ultrasound results of the VestSaync II trial
22. Evaluation of vascular healing of polymer-free sirolimuseluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging10.4244/EIJV12I5A97 ↗
23. Short-term effects of Nano+TM polymer-free sirolimus-eluting stents on native coronary vessels: an optical coherence tomography imaging study
24. Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the nano randomized trial10.3760/cma.j.issn.0366-6999.20133148 ↗
25. One-year clinical results of the NANO registry: a multicenter, prospective all-comers registry study in patients receiving implantation of a polymer-free sirolimus-eluting stent
26. First report of a novel polymer-free dual-drug eluting stent in de novo coronary artery disease: results of the first in human BICARE trial
27. Surface engineering at the nanoscale: a way forward to improve coronary stent efficacy10.1063/5.0037298 ↗
28. Bagheri · 2016 · 1309
29. Improving biocompatibility of implantable metals by nanoscale modification of surfaces: an overview of strategies, fabrication methods, and challenges10.1002/smll.200801186 ↗
30. Surface modification of medical devices at nanoscale-recent development and translational perspectives
31. Titanium dioxide nanotube arrays for cardiovascular stent applications10.1021/acsomega.9b04118 ↗
32. Enhanced cellular mobility guided by TiO2 nanotube surfaces10.1021/nl072572o ↗
33. Whole genome expression analysis reveals differential effects of TiO 2 nanotubes on vascular cells10.1021/nl903043z ↗
34. The effect of TiO2 nanotubes on endothelial function and smooth muscle proliferation10.1016/j.biomaterials.2008.11.012 ↗
35. Influence of Titania nanotopography on human vascular cell functionality and its proliferation in vitro10.1039/C1JM13726C ↗
36. Stable titania nanostructures on stainless steel coronary stent surface for enhanced corrosion resistance and endothelialization10.1002/adhm.201601353 ↗
37. Successful reduction of neointimal hyperplasia on stainless steel coronary stents by titania nanotexturing10.1021/acsomega.0c02045 ↗
38. The design of novel nanostructures on titanium by solution chemistry for an improved osteoblast response
39. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
40. step-by-step quantitative analysis of focal adhesions
41. Effect of baliospermum montanum nanomedicine apoptosis induction and anti-migration of prostate cancer cells
42. Impact of poly(lactic-co-glycolic acid) nanoparticle surface charge on protein, cellular and haematological interactions
43. Development of a rabbit model for a preclinical comparison of coronary stent types in-vivo10.4070/kcj.2013.43.11.713 ↗
44. Pathophysiology of coronary artery restenosis
45. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model10.1016/0735-1097(92)90476-4 ↗
46. Drug-eluting stents in preclinical studies: updated consensus recommendations for preclinical evaluation10.1161/CIRCINTERVENTIONS.108.789974 ↗
47. Passivation of stainless steels and other chromium bearing alloys
48. Micro- and nanotopographical cues guiding biomaterial host response
49. Controlling cell behavior through the Design of Biomaterial Surfaces: a focus on surface modification techniques10.1002/admi.201900572 ↗
50. From hydrophilicity to hydrophobicity: a critical review-part II: hydrophobic conversion
51. Hydrophilic and superhydrophilic surfaces and materials10.1039/c1sm05849e ↗
52. Superhydrophilic nanostructured surfaces of Beta Ti[Sbnd]29Nb alloy for cardiovascular stent applications
53. Computational characterization of the structural and mechanical properties of nanoporous titania10.1039/C9RA02298H ↗
54. Corrosion of titanium biomaterials, mechanisms, effects and modelisation10.1515/corrrev.2008.1 ↗
55. In-vitro characterization of stress corrosion cracking of aluminium-free magnesium alloys for temporary bio-implant applications
56. Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis
57. Extracellular matrix and integrin signalling: the shape of things to come10.1042/bj3390481 ↗
58. Biomaterial nanotopography-mediated cell responses: experiment and modeling10.1080/19475411.2014.995744 ↗
59. How surface topography relates to materials’ properties10.1126/science.1074955 ↗
60. Enhancement of the growth of human endothelial cells by surface roughness at nanometer scale10.1016/S0142-9612(03)00361-2 ↗
61. Response of MG63 osteoblast-like cells onto polycarbonate membrane surfaces with different micropore sizes10.1016/j.biomaterials.2003.11.034 ↗
62. Significance of synthetic nanostructures in dictating cellular response10.1016/j.nano.2004.11.008 ↗
63. Nanotextured stainless steel for improved corrosion resistance and biological response in coronary stenting10.1039/C4NR05015K ↗
64. Cellular and molecular responses of smooth muscle cells to surface nanotopography10.1166/jnn.2007.610 ↗
65. Recent advance in surface modification for regulating cell adhesion and behaviors10.1515/ntrev-2020-0076 ↗
66. In vitro investigation of hemocompatibility of hydrothermally treated titanium and titanium alloy surfaces10.1021/acsomega.0c00281 ↗
67. Effect of extreme wettability on platelet adhesion on metallic implants: from superhydrophilicity to superhydrophobicity10.1021/acsami.6b03644 ↗
68. Investigation on endothelialization of ti-O film modified vascular stent in vivo10.1080/10584587.2018.1456081 ↗
69. Functionally incomplete re-endothelialization of stents and neoatherosclerosis10.1016/j.jcin.2017.08.031 ↗
70. Fluorescent imaging of endothelial glycocalyx layer with wheat germ agglutinin using intravital microscopy10.1002/jemt.22602 ↗
71. The endothelial glycocalyx: composition, functions, and visualization10.1007/s00424-007-0212-8 ↗
72. The effects of stenting on coronary endothelium from a molecular biological view: time for improvement?10.1111/jcmm.13936 ↗
73. Endothelial repair and regeneration following intimal injury10.1007/s12265-016-9677-1 ↗
74. Stent thrombosis and optimal duration of dual antiplatelet therapy after coronary stenting in contemporary practice
75. Antiplatelet therapy after PCI in patients with high risk of bleeding10.3897/pharmacia.67.e52737 ↗
76. Coating defects in polymer-coated drug-eluting stents
77. Impact of stent surface on thrombogenicity and vascular healing10.1161/CIRCINTERVENTIONS.113.000120 ↗