journal article·2023-02-09Open access

Chromophoric cerium oxide nanoparticle-loaded sucking disk-type strip sensor for optical measurement of glucose in tear fluid

Sijin Park, Dong Yeon Nam, Hee-Jae Jeon, Jae Hoon Han, Dawon Jang, Juil Hwang, Yeong-Seo Park, Young-Geun Han, Young Bin Choy, Dong Yun Lee

Biomaterials Research· Volume 27· Issue 1

Abstract

Abstract Background Noninvasive monitoring of tear glucose levels can be convenient for patients to manage their diabetes mellitus. However, there are issues with monitoring tear glucose levels, such as the invasiveness of some methods, the miniaturization, inaccuracy, or the high cost of wearable devices. To overcome the issues, we newly designed a sucking disk-type (SD) strip biosensor that can quickly suck tear fluid and contains cerium oxide nanoparticle (CNP) that causes a unique color change according to the glucose level of the tear without complicated electronic components. Methods The SD strip biosensor composed of three distinct parts (tip, channel, and reaction chamber) was designed to contain the sensing paper, onto which tear fluid can be collected and delivered. The sensing paper treated with CNP/APTS (aminopropyltriethoxysilane) /GOx (glucose oxidase) was characterized. Then we carried out the reliability of the SD strip biosensor in the diabetic rabbit animals. We quantitatively analyzed the color values of the SD strip biosensor through the colorimetric analysis algorithm. Results We contacted the inferior palpebral conjunctiva (IPC) of a diabetic rabbit eye using an SD strip biosensor to collect tears without eye irritation and successfully verified the performance and quantitative efficacy of the sensor. An image processing algorithm that can optimize measurement accuracy is developed for accurate color change measurement of SD strip biosensors. The validation tests show a good correlation between glucose concentrations measured in the tear and blood. Conclusion Our findings demonstrate that the CNP-embedded SD strip biosensor and the associated image processing can simply monitor tear glucose to manage diabetes mellitus. Graphical Abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular Surface and Contact Lens · Advanced Drug Delivery Systems · Advanced Nanomaterials in Catalysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul 04763, Republic of Korea.

College of Engineering, Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro Gwanak-Gu, Seoul 08826, Republic of Korea.

Department of Mechanical and Biomedical Engineering, Kangwon National University, 1 Gangwondaehak-Gil, Chuncheon 24341, Republic of Korea.

Department of Physics, College of Natural Sciences, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul 04763, Republic of Korea.

Department of Biomedical Engineering, Seoul National University College of Medicine, 101 Daehak-Ro Jongno-Gu, Seoul 03080, Republic of Korea.

Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, 101 Daehak-Ro Jongno-Gu, Seoul 03080, Republic of Korea.

Institute of Nano Science and Technology (INST) and Institute for Bioengineering and Biopharmaceutical Research (IBBR), Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul 04763, Republic of Korea.

Elixir Pharmatech Inc, 222 Wangsimni-Ro Seongdong-Gu, Seoul 04763, Republic of Korea.

Funding

National Research Foundation of Korea · Korea Institute for Advancement of Technology

References (59)

Show source-provided references
1. 10.1038/s41581-020-0278-510.1038/s41581-020-0278-5 ↗
2. 10.1007/s12265-012-9388-110.1007/s12265-012-9388-1 ↗
3. 10.1001/jama.284.3.36310.1001/jama.284.3.363 ↗
4. 10.1080/03007995.2020.173491910.1080/03007995.2020.1734919 ↗
5. 10.1007/s40005-022-00594-810.1007/s40005-022-00594-8 ↗
6. 10.1007/s40005-022-00588-610.1007/s40005-022-00588-6 ↗
7. 10.1007/s40005-021-00513-310.1007/s40005-021-00513-3 ↗
8. 10.1007/s40005-018-0387-310.1007/s40005-018-0387-3 ↗
9. 10.1177/19322968120060022810.1177/193229681200600228 ↗
10. 10.1002/dmrr.51210.1002/dmrr.512 ↗
11. 10.12968/bjon.2011.20.15.91910.12968/bjon.2011.20.15.919 ↗
12. 10.3390/s10050455810.3390/s100504558 ↗
13. 10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-#10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# ↗
14. 10.1177/19322968080020052610.1177/193229680800200526 ↗
15. 10.1177/19322968100040050110.1177/193229681000400501 ↗
16. 10.1080/0271368060097655210.1080/02713680600976552 ↗
17. 10.1016/j.talanta.2017.08.07710.1016/j.talanta.2017.08.077 ↗
18. 10.1016/j.bios.2015.03.07010.1016/j.bios.2015.03.070 ↗
19. 10.1021/acs.analchem.8b0592810.1021/acs.analchem.8b05928 ↗
20. 10.1016/j.talanta.2021.12318710.1016/j.talanta.2021.123187 ↗
21. 10.1016/j.aca.2021.33838710.1016/j.aca.2021.338387 ↗
22. 10.3390/nano1207108210.3390/nano12071082 ↗
23. 10.1002/adhm.20170115010.1002/adhm.201701150 ↗
24. 10.1021/acs.analchem.1c0410610.1021/acs.analchem.1c04106 ↗
25. 10.3390/s2023692510.3390/s20236925 ↗
26. 10.1016/S1542-0124(12)70094-010.1016/S1542-0124(12)70094-0 ↗
27. 10.1126/sciadv.aba325210.1126/sciadv.aba3252 ↗
28. 10.1016/j.bios.2010.12.04210.1016/j.bios.2010.12.042 ↗
29. 10.1016/j.talanta.2010.10.05510.1016/j.talanta.2010.10.055 ↗
30. 10.1038/ncomms1499710.1038/ncomms14997 ↗
31. 10.1021/acs.nanolett.1c0188010.1021/acs.nanolett.1c01880 ↗
32. 10.7150/thno.7215210.7150/thno.72152 ↗
33. 10.1038/s41598-020-65103-z10.1038/s41598-020-65103-z ↗
34. 10.1021/acsanm.1c0060310.1021/acsanm.1c00603 ↗
35. 10.1002/adma.20211053610.1002/adma.202110536 ↗
36. 10.1016/j.biomaterials.2023.12231510.1016/j.biomaterials.2023.122315 ↗
37. 10.1016/j.bios.2013.05.01410.1016/j.bios.2013.05.014 ↗
38. So CF, Choi KS, Wong TK, Chung JW. Recent advances in noninvasive glucose monitoring. Med Devices (Auckl). 2012;5:45–52. 1:CAS:528:DC%2BC38XhtVakur3E
39. 10.1089/15209150477373137510.1089/152091504773731375 ↗
40. 10.1016/j.aanat.2012.10.00110.1016/j.aanat.2012.10.001 ↗
41. 10.1097/00003226-199707000-0001310.1097/00003226-199707000-00013 ↗
42. 10.1039/C6CC03609K10.1039/C6CC03609K ↗
43. 10.1097/ICO.000000000000160310.1097/ICO.0000000000001603 ↗
44. 10.1136/bjo.64.9.69310.1136/bjo.64.9.693 ↗
45. 10.1002/dmrr.21010.1002/dmrr.210 ↗
46. 10.1371/journal.pone.023931710.1371/journal.pone.0239317 ↗
47. 10.1021/ac201700c10.1021/ac201700c ↗
48. 10.1097/ICL.0b013e31811ead9310.1097/ICL.0b013e31811ead93 ↗
49. 10.1002/anie.20080527910.1002/anie.200805279 ↗
50. 10.2217/nnm.13.13310.2217/nnm.13.133 ↗
51. 10.3390/polym1505121810.3390/polym15051218 ↗
52. 10.1080/21655979.2016.122762910.1080/21655979.2016.1227629 ↗
53. 10.1021/ac200697y10.1021/ac200697y ↗
54. 10.1002/anie.20120758710.1002/anie.201207587 ↗
55. 10.1007/s40135-015-0073-910.1007/s40135-015-0073-9 ↗
56. 10.1038/s41598-019-41066-810.1038/s41598-019-41066-8 ↗
57. 10.1016/j.cis.2022.10265410.1016/j.cis.2022.102654 ↗
58. Mishima S, Gasset A, Klyce SD Jr, Baum JL. Determination of tear volume and tear flow. Invest Ophthalmol. 1966;5(3):264–276. 1:STN:280:DyaF287nsVWgsQ%3D%3D
59. 10.1016/j.jasms.2006.10.00210.1016/j.jasms.2006.10.002 ↗