Performance of marrow stromal cell-seeded small-caliber multilayered vascular graft in a senescent sheep model
Source abstract
Abstract
Abstract Failure of small-caliber grafts, used as bypass or reconstructive grafts in cardiovascular treatments, is often caused by thrombosis and stenosis. We have developed a multilayered, compliant graft with an electrospun heparin-encapsulated core and collagen-chitosan shell. Herein, the performances of acellular and cell-seeded grafts were evaluated in adult sheep for preclinical assessment. Allogeneic ovine marrow stroma cells (MSCs) were uniformly attached to the lumen of cell-seeded grafts. Interposition grafts were used for carotid arteries. Four grafts were tested for each type. Upon implantation, all grafts successfully restored perfusion and rhythmically deformed under pulsatile arterial flow. Weekly ultrasonography and Doppler revealed that all grafts remained patent for perfusion during the course of one-month study. No formation of blood clots or other complications were found. The diameter of graft lumen did not vary significantly over the time or with the graft type, while narrowing at anastomosis and significant thickening of graft wall were found in both types of grafts. More significant neotissue formation was found at anastomotic sections of acellular controls compared to cell-seeded grafts. Results from histological and immunofluorescent analyses revealed moderate intimal hyperplasia (IH) at anastomosis. When compared to cell-seeded grafts, acellular controls presented thicker IH composed of α-smooth muscle actin positive cells and ground substances, which correlated with reduced and more disturbing flow. IH was thickest at anastomosis and tapered off to a minimum in the mid-section. Few PECAM-positive cells appeared on cell-seeded grafts but not acellular controls. Additionally, lesser graft thickening was found in cell-seed grafts, which might be associated with the function of stromal cells in altering the fibrotic process during tissue repair. Results suggest that MSCs held the potential to reduce hyperplasia and improve healing in an aged, large animal model for vascular grafting.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Cardiac and Coronary Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University of Colorado at Boulder
Colorado State University
References (42)
Show source-provided references
1. Heart disease and stroke statistics—2015 update: A report from the American Heart Association10.1161/CIR.0000000000000152 ↗
2. Correlates of saphenous vein graft hyperplasia and occlusion 1 year after coronary artery bypass grafting analysis from the CASCADE randomized trial10.1161/CIRCULATIONAHA.112.000328 ↗
3. Future directions for vascular access for hemodialysis10.1111/sdi.12329 ↗
4. Vessel bioengineering—development of small-diameter arterial grafts10.1253/circj.CJ-13-1440 ↗
5. Heparin bonding does not improve patency of polytetrafluoroethylene arteriovenous grafts10.1016/j.avsg.2013.08.001 ↗
6. Role of bone marrow mononuclear cell seeding for nanofiber vascular grafts10.1089/ten.tea.2017.0044 ↗
7. Hemocompatible tissue-engineered vascular grafts using adult mesenchymal stem cells10.1016/j.cobme.2018.02.001 ↗
8. Mesenchymal stem cells and vascular regeneration10.1111/micc.12324 ↗
9. The tissue-engineered vascular graft—past, present, and future10.1089/ten.teb.2015.0100 ↗
10. Endothelium-derived relaxing and contracting factors10.1096/fasebj.3.9.2545495 ↗
11. Biomaterials for vascular tissue engineering10.2217/rme.09.77 ↗
12. Tissue-engineered vascular grafts created from human induced pluripotent stem cells10.5966/sctm.2014-0065 ↗
13. Patient-specific age: the other side of the coin in advanced mesenchymal stem cell therapy10.3389/fphys.2015.00362 ↗
14. Synergistic effect of angiotensin II on vascular endothelial growth factor-A-mediated differentiation of bone marrow-derived mesenchymal stem cells into endothelial cells10.1186/scrt538 ↗
15. Transient right internal thoracic arterial graft kink related to respiratory movements: documentation of its existence, relevance and proposed management10.1002/ccd.25220 ↗
16. A case of endovascular treatment of severe graft limb kinking after endovascular abdominal aortic aneurysm repair10.5758/vsi.2016.32.1.26 ↗
17. Animal models in tissue engineering: I. Introduction10.1089/ten.tec.2017.0402 ↗
18. Animal models in tissue engineering: II10.1089/ten.tec.2017.0458 ↗
19. The performance of a small-calibre graft for vascular reconstructions in a senescent sheep model10.1016/j.biomaterials.2014.07.008 ↗
20. Implantation of completely biological engineered grafts following decellularization into the sheep femoral artery10.1089/ten.tea.2013.0550 ↗
21. Mechanical and biocompatible characterizations of a readily available multilayer vascular graft10.1002/jbm.b.32851 ↗
22. The mechanical behavior of vascular grafts: a review10.1106/NA5T-J57A-JTDD-FD04 ↗
23. Prospective isolation of mesenchymal stem cells from multiple mammalian species using cross-reacting anti-human monoclonal antibodies10.1089/scd.2009.0510 ↗
24. Cell-seeding techniques in vascular tissue engineering10.1089/ten.teb.2009.0527 ↗
25. Adventitial fibroblast reactive oxygen species as autocrine and paracrine mediators of remodeling: bellwether for vascular disease?10.1016/j.cardiores.2007.06.016 ↗
26. Fibroblast activation in vascular inflammation10.1111/j.1538-7836.2011.04209.x ↗
27. Management of fibrosis: the mesenchymal stromal cells breakthrough10.1155/2014/340257 ↗
28. Use of mesenchymal stem cells for therapy of cardiac disease10.1161/CIRCRESAHA.116.303614 ↗
29. Synergism of matrix stiffness and vascular endothelial growth factor on mesenchymal stem cells for vascular endothelial regeneration10.1089/ten.tea.2013.0249 ↗
30. Shear stress and circumferential stretch by pulsatile flow direct vascular endothelial lineage commitment of mesenchymal stem cells in engineered blood vessels10.1007/s10856-016-5670-0 ↗
31. The role of mechanical stimuli in the vascular differentiation of mesenchymal stem cells10.1242/jcs.167783 ↗
32. Deconstructing the tissue engineered vascular graft: evaluating scaffold pre-wetting, conditioned media incubation, and determining the optimal mononuclear cell source10.1021/acsbiomaterials.6b00123 ↗
33. Mesenchymal stem cells: environmentally responsive therapeutics for regenerative medicine10.1038/emm.2013.94 ↗
34. Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft10.1016/j.jvs.2016.09.034 ↗
35. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis10.1016/j.jvs.2013.03.004 ↗
36. Development and in vivo evaluation of small-diameter vascular grafts engineered by outgrowth endothelial cells and electrospun chitosan/poly(ε-caprolactone) nanofibrous scaffolds10.1089/ten.tea.2013.0020 ↗
37. Tissue-engineered small diameter arterial vascular grafts from cell-free nanofiber pcl/chitosan scaffolds in a sheep model10.1371/journal.pone.0158555 ↗
38. Prosthetic vascular grafts: wrong models, wrong questions and no healing10.1016/j.biomaterials.2007.07.017 ↗
39. Animal models for the assessment of novel vascular conduits10.1016/j.jvs.2009.10.080 ↗
40. Contribution of endothelial injury and inflammation in early phase to vein graft failure: the causal factors impact on the development of intimal hyperplasia in murine models10.1371/journal.pone.0098904 ↗
41. Mesenchymal stem/stromal cells in regenerative medicine: can preconditioning strategies improve therapeutic efficacy?10.1159/000447458 ↗
42. Quantifiable metrics for predicting MSC therapeutic efficacy10.4172/2157-7633.1000365 ↗