The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
Source abstract
Abstract
This study investigated the effect of three different parameters of a dental implant on stress and strain values in the peri-implant bone by finite element analysis. In this work, the effect of diameter, length and elastic modulus on the biomechanical behavior of a new dental implant was simulated using the finite element method. A three-dimensional model of a mandible segment corresponding to the premolar region and twelve dental implant models were obtained. Loads in three directions were distributed on the surface of the coronal area of the dental implants. The dental implant models were obtained in the FreeCAD 0.16 software and the simulations were made using the Abaqus/CAE software. In all cases, higher stress concentrations were obtained in the peri-implant cortical bone between 40.6 and 62.8 MPa, while the highest levels of strain were observed in the peri-implant trabecular bone between 0.002544 and 0.003873. In general, the highest von Mises equivalent stress values were observed in the peri-implant cortical bone. However, in this bone, both the maximum von Mises equivalent stress values and the von Mises strain are similar or inferior to those reported in different studies by finite element for other models of dental implants under immediate loading. Maximum von Mises strain values were observed in peri-implant trabecular bone. However, in this bone strains levels were obtained that maintain bone density or increase it. The effect of the three simulated variables (implant diameter, length, and elastic modulus) have a statistically significant influence on the von Mises equivalent stress and in von Mises strain values.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
, , Technological University of Havana José Antonio Echeverría, Cuba
Autonomous University of Nuevo León, , México
, , University of Havana, Cuba
References (32)
Show source-provided references
1. The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis10.5051/jpis.2016.46.3.152 ↗
2. The influence of mechanical loads on the biomechanics of dental implant
3. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis10.1111/j.1600-0501.2005.01132.x ↗
4. Simulation of peri-implant bone healing due to immediate loading in dental implant treatments10.1016/j.jbiomech.2012.12.023 ↗
5. Immediate occlusal loading of Osseotite implants in the lower edentulous jaw10.1111/j.1600-0501.2004.01013.x ↗
6. Immediately loaded platform-switched implants in the anterior mandible with fixed prostheses: a randomized, split-mouth, masked prospective trial10.1111/cid.12065 ↗
7. Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis10.4047/jap.2013.5.3.333 ↗
8. Influence of three different implant thread designs on stress distribution: a three-dimensional finite element analysis10.4103/0972-4052.191283 ↗
9. Computational and experimental studies in threaded dental implant research
10. Influence of implant length, diameter, and geometry on stress distribution: a finite element analysis
11. Influence of implant length and diameter on stress distribution: a finite element analysis10.1016/j.prosdent.2003.08.008 ↗
12. The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis10.1007/s00784-009-0305-1 ↗
13. Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis
14. Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area10.1007/s00784-011-0517-z ↗
15. Selection of the implant thread pitch for optimal biomechanical properties: a three-dimensional finite element analysis10.1016/j.advengsoft.2008.08.003 ↗
16. Effects of overloading in mastication on the mechanical behaviour of dental implants10.1016/j.matdes.2012.12.019 ↗
17. Influence of occlusal loading on stress patterns at the bone-implant interface by angulated abutments in the anterior maxilla: a three-dimensional finite-element study
18. Bone remodeling induced by dental implants of functionally graded materials
19. Lekholm · 1985 · 199
20. Combined effects of implant insertion depth and alveolar bone quality on periimplant bone strain induced by a wide-diameter, short implant and a narrow-diameter, long implant10.1016/S0022-3913(10)60142-4 ↗
21. Three-dimensional finite element analysis of the effects of implant diameter and photofunctionalization on peri-implant stress10.2334/josnusd.16-0144 ↗
22. A three-dimensional finite element study on the biomechanical simulation of various structured dental implants and their surrounding bone tissues10.1155/2016/4867402 ↗
23. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis10.1111/j.1532-849X.2009.00453.x ↗
24. Effect of microthread design of dental implants on stress and strain patterns: a three-dimensional finite element analysis10.1515/bmt-2012-0108 ↗
25. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants10.1111/j.1708-8208.2008.00124.x ↗
26. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis
27. Regular and platform switching: bone stress analysis varying implant type10.1111/j.1532-849X.2011.00801.x ↗
28. Mohamed · 2014
29. Dental implant induced bone remodeling and associated algorithms10.1016/j.jmbbm.2008.11.007 ↗
30. Three-dimensional finite element analysis of varying diameter and connection type in implants with high crown-implant ratio10.1590/0103-6440201801746 ↗
31. Influence of implant surface topography and loading condition on stress distribution in bone around implants: a comparative 3D FEA10.1007/s13191-011-0105-6 ↗
32. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study10.1034/j.1600-0501.2001.012003207.x ↗