Biomechanical effect with respect to the sagittal positioning of the femoral component in unicompartmental knee arthroplasty
Source abstract
Abstract
BACKGROUND: Component malalignment in unicompartmental knee arthroplasty (UKA) has been related to the concentration in tibiofemoral joint of contact stress and to poor post-operative outcomes. Few studies investigated a biomechanical effect of femur component position in sagittal plane. The purpose of this study was to evaluate the biomechanical effect of the femoral components on the sagittal alignment under flexion and extension conditions using computational simulations. METHODS: The flexion and extension conditions of the femoral component were analyzed from 10° extension to 10° flexion in 1° increments. We considered the contact stresses in the polyethylene (PE) inserts and articular cartilage, and the force on the collateral ligament, under gait cycle conditions. RESULTS: The contact stress on the PE insert increased as flexion of the femoral component increased, but there was not a remarkable difference in the amount of increased contact stress upon extension. There was no difference in the contact stress on the articular cartilage upon extension of the femoral component, but it increased in flexion during stance and double support periods. The forces on the medial collateral ligaments increased with the extension and decreased with the flexion of the femoral component, whereas the forces on the lateral collateral ligaments showed opposite trends. CONCLUSIONS: Surgeons should be concerned with femoral component position on UKA not only in frontal plane but also in the sagittal plane, because flexion or extension of the femoral component may impact the PE or opposite compartment along with the surrounding ligaments around knee joint.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Knee injuries and reconstruction techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
, , , Republic of Korea
, , , , Republic of Korea
References (47)
Show source-provided references
1. Unicondylar knee arthroplasty10.2106/00004623-198971010-00023 ↗
2. Robotic arm-assisted UKA improves tibial component alignment: A pilot study10.1007/s11999-009-0977-5 ↗
3. Outcomes and survivorship of unicondylar knee arthroplasty in patients with severe deformity10.1007/s00167-014-3464-9 ↗
4. Unicompartmental knee arthroplasty is effective: Ten year results10.1007/s00264-015-2809-4 ↗
5. Implant position in knee surgery: a comparison of minimally invasive, open unicompartmental, and total knee arthroplasty10.1016/S0883-5403(03)00291-2 ↗
6. Alignment influences wear in the knee after medial unicompartmental arthroplasty10.1097/01.blo.0000128285.90459.12 ↗
7. Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty10.2106/00004623-200403000-00007 ↗
8. Accuracy of implantation of components in the Oxford knee using the minimally invasive approach10.1016/j.knee.2005.03.003 ↗
9. Influence of component alignment on outcome for unicompartmental knee replacement10.1016/j.knee.2008.11.001 ↗
10. Medial unicompartmental arthroplasty. A survival study of the Oxford meniscal knee
11. Importance of joint line preservation in unicompartmental knee arthroplasty: Finite element analysis10.1002/jor.23279 ↗
12. The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty10.1016/S0021-9290(01)00244-5 ↗
13. Evaluation of factors affecting tibial bone strain after unicompartmental knee replacement10.1002/jor.22283 ↗
14. Three-dimensional finite element analysis of unicompartmental knee arthroplasty–the influence of tibial component inclination10.1016/j.orthres.2004.06.007 ↗
15. The ‘instantaneous’ compressive modulus of human articular cartilage in joints of the lower limb10.1093/rheumatology/38.2.124 ↗
16. Elevated proximal tibial strains following unicompartmental knee replacement–a possible cause of pain10.1016/j.medengphy.2009.02.004 ↗
17. Finite element analysis of mobile-bearing unicompartmental knee arthroplasty: The influence of tibial component coronal alignment10.4103/0366-6999.168044 ↗
18. Computational model-based probabilistic analysis of in vivo material properties for ligament stiffness using the laxity test and computed tomography10.1007/s10856-016-5797-z ↗
19. Probabilistic evaluation of the material properties of the in vivo subject-specific articular surface using a computational model10.1002/jbm.b.33666 ↗
20. Graft Extrusion Related to the Position of Allograft in Lateral Meniscal Allograft Transplantation: Biomechanical Comparison Between Parapatellar and Transpatellar Approaches Using Finite Element Analysis10.1016/j.arthro.2015.06.030 ↗
21. Why lateral meniscectomy is more dangerous than medial meniscectomy. A finite element study10.1002/jor.20037 ↗
22. Validation of a three-dimensional model of the knee10.1016/0021-9290(95)00149-2 ↗
23. Biomechanics of the knee joint in flexion under various quadriceps forces10.1016/j.knee.2005.03.004 ↗
24. The Anatomy of the Medial Patellofemoral Ligament10.1177/0363546509339909 ↗
25. Anatomy and biomechanics of the posterior cruciate ligament, medial and lateral sides of the knee10.1097/JSA.0b013e3181f917e2 ↗
26. Anterior cruciate ligament femoral footprint anatomy: Systematic review of the 21st century literature10.1016/j.arthro.2011.11.026 ↗
27. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint10.1016/S0021-9290(02)00305-6 ↗
28. Inc. · 2004
29. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis10.1016/S0021-9290(01)00179-8 ↗
30. Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study
31. The valgus inclination of the tibial component increases the risk of medial tibial condylar fractures in unicompartmental knee arthroplasty10.1016/j.arth.2016.02.043 ↗
32. Function of the anterior cruciate ligament after unicompartmental knee arthroplasty: An in vitro robotic study10.1016/j.arth.2003.08.018 ↗
33. [Anonymous]. ISO 14243-1. Implants for surgery. Wear of total knee joint prostheses. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test, 2002.
34. The effects of posterior cruciate ligament deficiency on posterolateral corner structures under gait- and squat-loading conditions: A computational knee model10.1302/2046-3758.61.BJR-2016-0184.R1 ↗
35. Verification of predicted knee replacement kinematics during simulated gait in the Kansas knee simulator10.1115/1.4001678 ↗
36. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation10.1302/2046-3758.511.BJR-2016-0107.R1 ↗
37. Loading of the knee joint during activities of daily living measured in vivo in five subjects10.1016/j.jbiomech.2010.03.046 ↗
38. Goodfellow · 2006
39. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: A retrieval study of 16 specimens10.1302/0301-620X.80B6.0800976 ↗
40. Accuracy and early outcomes in medial unicompartmental knee arthroplasty performed using patient specific instrumentation10.1016/S0968-0160(14)50007-5 ↗
41. Minimally invasive robotic-arm-guided unicompartmental knee arthroplasty
42. Radiographic comparison of mobile-bearing partial knee single-peg versus twin-peg design10.1016/j.arth.2014.10.015 ↗
43. Baseline articular contact stress levels predict incident symptomatic knee osteoarthritis development in the MOST cohort10.1002/jor.20936 ↗
44. Biomechanical effects of different varus and valgus alignments in medial unicompartmental knee arthroplasty10.1016/j.arth.2016.07.006 ↗
45. Effects of radial tears and partial meniscectomy of lateral meniscus on the knee joint mechanics during the stance phase of the gait cycle–A 3D finite element study10.1002/jor.22358 ↗
46. Influence of increased posterior tibial slope in total knee arthroplasty on knee joint biomechanics: A computational simulation study10.1016/j.arth.2017.09.025 ↗
47. Biomechanical effects of total knee arthroplasty component malrotation: A computational simulation10.1002/jor.21344 ↗