Numerical investigations of the mechanical properties of braided vascular stents
Source abstract
Abstract
BACKGROUND: Braided stents, such as Pipeline Embolization Device (PED; ev3 Neurovascular, Irvine, CA, USA), are commonly used to treat cerebral aneurysms. However, little information is available on the compression and bending characteristics of such stents. OBJECTIVE: This paper investigates how geometrical parameters of braided stents influence their radial compression and bending characteristics. METHODS: Six groups of braided stent models with different braiding angles, numbers of wires and wire diameters are constructed. Parametric analyses of these models are conducted using Abaqus/Explicit software. The numerical results of a finite element analysis are validated by comparison with data of theoretical analysis. RESULTS: The results show that the radial stiffness is not uniform along the longitudinal direction of the stent. When the braiding angle increases from 30° to 75°, the minimum radial deformation decreases from 0.85 mm to 0.0325 mm (at a pressure of 500 Pa, for 24 braided wires). When the wire diameter increases from 0.026 mm to 0.052 mm, the minimum radial deformation decreases from 0.65 mm to 0.055 mm (at a pressure of 500 Pa and a braiding angle of 60°, for 24 braided wires). Frictions don't affect stent diameter and its axial length when braided stent is crimping, but the friction must be considered when it is related to the radial pressure required for compression the braided stent. CONCLUSIONS: Compared with commonly used intracranial stents, a braided stent with geometrical parameters close to PED stent has a smaller radial stiffness but a considerably greater longitudinal flexibility. The results of this analysis of braided stents can help in the design and selection of flow diverter stents for clinical treatment of cerebral aneurysms.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Intracranial Aneurysms: Treatment and Complications · Vascular Malformations Diagnosis and Treatment · Advanced Numerical Methods in Computational Mathematics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Mechanical and Electrical Engineering, Beijing Union University, Beijing 100020, China
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
Department of Civil Engineering, University of Ottawa, Ottawa, K1N 6N5, Canada
College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China. E-mail: qak@bjut.edu.cn
References (17)
Show source-provided references
1. Numerical investigations of the mechanical properties of a braided non-vascular stent design using finite element method10.1080/10255842.2013.873420 ↗
2. Mechanical response of a metallic aortic stent – part I: Pressure-diameter relationship10.1115/1.1782650 ↗
3. Mechanical response of a metallic aortic stent – part II. A beam-on-elastic foundation model10.1115/1.1782912 ↗
4. S.J. Zhao, X.Y. Liu and L.X. Gu, The impact of wire stent fabrication technique on the performance of stent placement, J. Med. Devices (2012), 011007.10.1115/1.4005788 ↗
5. Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms10.1016/j.jbiomech.2012.06.013 ↗
6. High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: In vitro and in silico10.1007/s10439-013-0808-4 ↗
7. Mechanical modeling of self-expandable stent fabricated using braiding technology10.1016/j.jbiomech.2008.08.005 ↗
8. Virtual optimization of self-expandable braided wire stents10.1016/j.medengphy.2008.11.008 ↗
9. A study of the geometrical and mechanical properties of a self-expanding metallic stent-theory and experiment10.1002/jab.770040111 ↗
10. Mathematical model analysis of Wallstent® and AneuRx® – dynamic responses of baremetal endoprosthesis compared with those of stent-graft
11. Comparative friction of orthodontic wires under dry and wet conditions10.1016/0002-9416(86)90006-0 ↗
12. Contact and friction between catheter and blood vessel10.1016/j.triboint.2005.10.010 ↗
13. A new flow diverter stent for direct treatment of intracranial aneurysm10.1016/j.jbiomech.2015.10.024 ↗
14. A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]10.1055/s-0031-1271681 ↗
15. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation10.1161/CIRCULATIONAHA.106.658237 ↗
16. Spontaneous delayed migration/short-ening of the pipeline embolization device: Report of 5 cases10.3174/ajnr.A3632 ↗
17. Variable porosity of the pipeline embolization device in straight and curved vessels: A guide for optimal deployment strategy10.3174/ajnr.A3742 ↗