journal article·2017-07-12Open access

Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography

Kyoung-Tak Kang, Sung-Hwan Kim, Juhyun Son, Young Han Lee, Yong-Gon Koh

Abstract

BACKGROUND: Computational models have been identified as efficient techniques in the clinical decision-making process. However, computational model was validated using published data in most previous studies, and the kinematic validation of such models still remains a challenge. Recently, studies using medical imaging have provided a more accurate visualization of knee joint kinematics. OBJECTIVE: The purpose of the present study was to perform kinematic validation for the subject-specific computational knee joint model by comparison with subject's medical imaging under identical laxity condition. METHODS: The laxity test was applied to the anterior-posterior drawer under 90° flexion and the varus-valgus under 20° flexion with a series of stress radiographs, a Telos device, and computed tomography. The loading condition in the computational subject-specific knee joint model was identical to the laxity test condition in the medical image. RESULTS: Our computational model showed knee laxity kinematic trends that were consistent with the computed tomography images, except for negligible differences because of the indirect application of the subject's in vivo material properties. CONCLUSIONS: Medical imaging based on computed tomography with the laxity test allowed us to measure not only the precise translation but also the rotation of the knee joint. This methodology will be beneficial in the validation of laxity tests for subject- or patient-specific computational models.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Knee injuries and reconstruction techniques · Osteoarthritis Treatment and Mechanisms

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea

Department of Orthopedic Surgery, Gangnam Severance Hospital, Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea

Department of Radiology, Research Institute of Radiological Science, Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea

Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 50 Yonsei-ro, Seodaemun-gu, Seoul, 06698, Republic of Korea

References (34)

Show source-provided references
1. Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together10.1016/j.jbiomech.2014.04.002 ↗
2. The effect of ligament modeling technique on knee joint kinematics: A finite element study
3. Current concepts in instrumented knee-laxity testing10.1177/0363546508323746 ↗
4. Stress radiographical measurement of the anteroposterior, medial and lateral stability of the knee joint10.3109/17453677608992002 ↗
5. A validated three-dimensional computational model of a human knee joint10.1115/1.2800871 ↗
6. Anterior cruciate ligament reconstruction and cartilage contact forces – A 3D computational simulation10.1016/j.clinbiomech.2015.08.007 ↗
7. Cartilage pressure distributions provide a footprint to define female anterior cruciate ligament injury mechanisms10.1177/0363546511400980 ↗
8. Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles10.1007/s11517-010-0653-7 ↗
9. Subject-specific finite element analysis to characterize the influence of geometry and material properties in Achilles tendon rupture10.1016/j.jbiomech.2014.10.001 ↗
10. Prediction and validation of load-dependent behavior of the tibiofemoral and patellofemoral joints during movement10.1007/s10439-015-1326-3 ↗
11. In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area10.1007/s12541-015-0151-9 ↗
12. Accuracy and reliability of length measurements on three-dimensional computed tomography using open-source OsiriX software10.1007/s10278-012-9458-6 ↗
13. The isometry of two different paths for remnant-preserving posterior cruciate ligament reconstruction10.1007/s00167-012-2111-6 ↗
14. Non-operative treatment of complete tears of the medial collateral ligament of the knee10.2106/00004623-198365030-00005 ↗
15. Nonoperative management of complete tears of the medial collateral ligament of the knee in intercollegiate football players10.1097/00003086-199007000-00025 ↗
16. Posterior instability of the knee near extension. A clinical and stress radiographic analysis of acute injuries of the posterior cruciate ligament10.1302/0301-620X.72B2.2312560 ↗
17. The anatomical tibial axis: Reliable rotational orientation in knee replacement10.1302/0301-620X.90B8.19905 ↗
18. Considerations in measuring cartilage thickness using MRI: Factors influencing reproducibility and accuracy10.1016/j.joca.2005.04.013 ↗
19. The accuracy of three-dimensional reconstructions of the ovine knee: Dissectional validation10.1016/S0895-6111(02)00006-X ↗
20. Probabilistic approach for determining the material properties of meniscal attachments in vivo using magnetic resonance imaging and a finite element model10.1089/cmb.2015.0126 ↗
21. Graft extrusion related to the position of allograft in lateral meniscal allograft transplantation: Biomechanical comparison between parapatellar and transpatellar approaches using finite element analysis10.1016/j.arthro.2015.06.030 ↗
22. The ‘instantaneous’ compressive modulus of human articular cartilage in joints of the lower limb10.1093/rheumatology/38.2.124 ↗
23. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint10.1016/S0021-9290(02)00305-6 ↗
24. Efficient probabilistic representation of tibiofemoral soft tissue constraint10.1080/10255840902822550 ↗
25. Biomechanics of the knee joint in flexion under various quadriceps forces10.1016/j.knee.2005.03.004 ↗
26. Biomechanical function of the human anterior cruciate ligament10.1016/S0749-8063(05)80081-7 ↗
27. Validation of a three-dimensional model of the knee10.1016/0021-9290(95)00149-2 ↗
28. Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics10.1016/j.jbiomech.2007.08.015 ↗
29. Sensitivity of the tibio-femoral response to finite element modeling parameters10.1080/10255840701283988 ↗
30. Sensitivities of medial meniscal motion and deformation to material properties of articular cartilage, meniscus and meniscal attachments using design of experiments methods10.1115/1.2191077 ↗
31. Costs, charges, and revenues for hospital diagnostic imaging procedures: Differences by modality and hospital characteristics10.1016/j.jacr.2004.09.013 ↗
32. An in vivo 3D computed tomographic analysis of femoral tunnel geometry and aperture morphology between rigid and flexible systems in double-bundle anterior cruciate ligament reconstruction using the transportal technique10.1016/j.arthro.2015.01.021 ↗
33. Reliability of stress radiography for evaluation of posterior knee laxity10.1177/0363546504269723 ↗
34. Biomechanics of knee ligaments10.1177/03635465990270042301 ↗