Postoperative endophthalmitis following intraocular lens (IOL) implantation is still one of the most feared complications of cataract surgery. Bacterial adhesion to IOLs during their insertion is a prominent etiological factor. Polypropylene was the first biomaterial that allowed this relation of cause and effect to be proven. Following adhesion, bacteria replicate, congregate and form multiple layers of microcolonies which actually represent the basic structural unit of the biofilm. The bacteria are embedded in a slime layer. Personal photographs illustrate the different steps of biofilm formation. This slime matrix is not only an adhesive medium; it also affects virulence. Adhesion to IOLs has been studied by several in vitro studies and discrepancies can be found between them which are due to variations of experimental conditions. The strains, the incubation times and the methods all varied. Adhesion is affected by the nature of the IOLs, the isolates and the surrounding medium. Since this medium is very difficult to model because of its complexity, in vivo studies seemed essential. We have recently determined in vivo evolution of the amount of attached bacteria to five types of IOLs. Crystalline lenses from 90 domestic pigs were removed aseptically and replaced with previously infected IOLs. There have been few epidemiological studies published to determine the relationship between endophthalmitis and the IOL type. However, the perfect biomaterial that could prevent postoperative endophthalmitis does not yet exist. Globally, hydrophilic materials and hydrophobic acrylic seem to be less sticky than silicone or PMMA, but this remains to be proven clinically.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular Infections and Treatments · Intraocular Surgery and Lenses · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Ophthalmology, Croix‐Rousse Hospital, Lyon, France

Department of Ophthalmology, Edouard Herriot Hospital, Lyon, France

Laboratory “Biomaterials and Matrix Remodeling”, EA 3090, Claude Bernard University, Lyon, France

Department of Microbiology, EA 819, Cinétique des xénobiotiques, Faculté de pharmacie, Université Paul Sabatier, Toulouse, France

Department of Microbiology, Institut des Sciences Pharmaceutiques et Biologiques, Lyon, France

References

Reference metadata was not supplied for this record.