journal article·2016-11-25

Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes

Didem Nalbantgil, Feyza Ulkur, Gulfeza Kardas, Mustafa Culha

Publisher page

Abstract

BACKGROUND: Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE: To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompatible and mechanically useful arch wire and mouthwash combination. METHODS: Each group comprised of 4 wire samples of 2 cm 0.016 × 0.022 inch. 1st group: ion implanted nickel titanium (INT), 2nd group: nickel titanium, without ion implantation (NT), 3rd group: micro layered esthetic nickel titanium (ENT), 4th group: stainless steel (SS) wires. They were immersed inside 2 ml of artificial saliva solutions (AS) for the control, or AS (9%) combined with 1 of the 3 mouthwashes (91%) for study groups, for 24 hours. These mouthwashes were essential oil (EO), chlorhexidine (CHX), sodium-fluoride (NaF). An electrochemical analyzer was used for electrochemical impedance spectroscopy measurements. RESULTS: High corrosion resistance was obtained for ENT than the other wires. The corrosion potentials are 0.007, -0.042, 0.074 and -0.015 V (Ag/AgCl) for ENT, INT, SS and NT in the artificial salivary, respectively. In NaF containing mouthwash Rp value of ENT is significantly high in comparison to others. The impedance responses of all materials increased significantly in the presence of NaF mouthwash as well as in the CHX mouthwash. Low frequencies are seen at all materials in EO mouthwash. Diameters of loops are 22, 5.9, 5.9 and 3.7 MΩ at ENT, INT, SS and NT. CONCLUSIONS: In this study, micro layered esthetic nickel titanium wires are found biocompatible among other wires and NaF and CHX mouthwashes can be recommend for their good corrosion resistance during fixed orthodontic therapy.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey

Physical Chemistry Department, Faculty of Arts and Sciences, Cukurova University, Adana, Turkey

Department of Genetics and Bioengineering, Faculty of Engineering and Architecture, Yeditepe University, Istanbul, Turkey

References (32)

Show source-provided references
1. Degradation in performance of orthodontic wires caused by hydrogen absorption during short-term immersion in 2.0% acidulated phosphate fluoride solution
2. Delayed fracture of beta titanium orthodontic wire in fluoride aqueous solutions10.1016/S0142-9612(02)00642-7 ↗
3. Effect of acidic fluoride solution on beta titanium alloy wire10.1002/jbm.b.30212 ↗
4. Biomaterial and implant surfaces: On the role of cleanliness, contamination, and preparation procedures10.1002/jbm.820221307 ↗
5. Corrosion of orthodontic appliances – Should we care?10.1016/j.ajodo.2007.03.021 ↗
6. Mechanical properties and surface of characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment10.2319/0003-3219(2007)077[0342:MPASCO]2.0.CO;2 ↗
7. Corrosion-related changes on Ti-based orthodontic brackets in acetic NaF solutions: Surface morphology, microhardness, and element release10.4012/dmj.27.555 ↗
8. 10.2319/050914-335.110.2319/050914-335.1 ↗
9. In vivo aging of orthodontic alloys: Implications for corrosion potential, nickel release, and biocompatibility
10. Release of toxic ions from silver solder used in orthodontics: An in-situ evaluation10.1016/j.ajodo.2010.06.024 ↗
11. Surface analysis and corrosion resistance of different stainless steel orthodontic brackets in artificial saliva
12. Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys10.4012/dmj.21.83 ↗
13. Influence of fluoridated mouthwashes on corrosion resistance of orthodontic wires10.1016/j.biomaterials.2003.11.042 ↗
14. Variation in corrosion resistance of nickel–titanium wires from different manufacturers
15. In vitro evaluation of physical vapor deposition coated beta titanium orthodontic arcwires10.2319/040811-251.1 ↗
16. Effects of intraoral aging on surface properties of coated nickel–titanium archwires10.2319/081213-593.1 ↗
17. Ion release from NiTi orthodontic wires in artificial saliva with various acidities10.1016/S0142-9612(03)00188-1 ↗
18. The influence of albumin on corrosion resistance of titanium in fluoride solution10.4012/dmj.22.359 ↗
19. Corrosion kinetics and topography analysis of Ti-6Al-4V alloy subjected to different mouthwash solutions10.1016/j.msec.2014.06.033 ↗
20. The frictional behavior of coated guiding archwires10.1007/s00056-002-0009-5 ↗
21. Corrosion behavior of ion implanted nickel–titanium orthodontic wire in fluoride mouth rinse solutions10.4012/dmj.2009-069 ↗
22. Corrosion inhibition of mild steel by alkylimidazolium ionic liquids in hydrochloric acid10.1016/j.electacta.2008.10.025 ↗
23. Corrosion inhibition of armco iron in 1 M HCl media by new bipyrazolic derivatives10.1016/S0010-938X(99)00123-7 ↗
24. Effect of carbon steel microstructures and molecular structure of two new Schiff base compounds on inhibition performance in 1 M HCl solution by EIS10.1016/j.matchemphys.2008.08.026 ↗
25. The inhibitive effect of some bis-N,S-bidentate Schiff bases on corrosion behavior of 304 stainless steel in hydrochloric acid solution10.1016/j.corsci.2009.02.011 ↗
26. Benzimidazole and its derivatives as corrosion inhibitors for mild steel in 1 M HCl solution10.1016/j.corsci.2009.05.011 ↗
27. Bis (benzimidazol-2-yl) disulphide: An efficient water-soluble inhibitor for corrosion of mild steel in acid media10.1016/j.corsci.2009.05.026 ↗
28. Deyab · Colloid Surf. A · 2008 · 348 · 17010.1016/j.colsurfa.2009.07.016 ↗
29. Guanidine derivative as a new corrosion inhibitor for copper in 3% NaCl solution10.1016/j.matchemphys.2008.05.052 ↗
30. Corrosion inhibition of copper by 2,5-dimercapto-1,3,4-thiadiazole monolayer in acidic solution10.1016/j.corsci.2010.12.002 ↗
31. Inhibition effect of some amino acids on copper corrosion in HCl solution10.1016/j.matchemphys.2008.05.060 ↗
32. Arginine self-assembled monolayers against copper corrosion and synergistic effect of iodide ion10.1007/s10800-009-9784-7 ↗