journal article·2022-03

Behavior of implant and abutment sets of three different connections during the non-axial load application: An in vitro experimental study using a radiographic method

Sergio Alexandre Gehrke, Berenice Anina Dedavid, José Manuel Granero Marín, Luigi Canullo

Publisher page

Abstract

BACKGROUND: During the masticatory cycle, loads of different intensities and directions are received by the dental structures and/or implants, which can cause micromovements at the junction between the abutment and implant. OBJECTIVE: The objective of this in vitro study was to evaluate the behavior of three different implant connections subjected to different load values using a digital radiography system. Additionally, the torque values for removing the abutment screws were also measured and compared. METHODS: Ninety sets of implant and abutment (IA) were used, divided into three groups according to the type of connection ( n = 30 per group): EH group, external hexagon type connection; IH group, internal hexagon connection; and, MT group, Morse taper connection. RESULTS: MT group showed the better vertical misfit behavior at the three intensity of load applied, in comparison with EH and IH groups. In the analysis of torque maintenance (detorque test), MT group showed higher values of detorque when compared with the measured values of EH and IH groups ( p < 0.001). CONCLUSIONS: The IA sets of EH and IH groups showed a microgap in all levels of applied loads, unlike the MT group this event was not observed. In the detorque test, MT group increase in the torque values when compared to the initial torque applied, unlike EH and IH groups showed a decrease in the initially torque applied in all conditions tested. A positive correlation was detected between the misfit and detorque values.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Periodontal Regeneration and Treatments · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Research, Biotecnos, Montevideo, Uruguay

Department of Biotechnology, Universidad Católica de Murcia (UCAM), Murcia, Spain

Department of Materials Engineering, Pontificia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil

Faculty of Medicine and Dentistry, Universidad Católica de Murcia (UCAM), Murcia, Sapin

Private Practice, Rome, Italy

References (44)

Show source-provided references
1. HsuM.L. ChenF.C. KaoH.C. and ChengC.K., Influence of off-axis loading of an anterior maxillary implant: A 3-dimensional finite element analysis, Int J Oral Maxillofac Implants 22(2) (2007), 301–309.
2. SütpidelerM. EckertS.E. ZobitzM. and AnK.N., Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone, Int J Oral Maxillofac Implants 19(6) (2004), 819–825.
3. MeniniM. PesceP. BagnascoF. CarossaM. MussanoF. and PeraF., Evaluation of internal and external hexagon connections in immediately loaded full-arch rehabilitations: A within-person randomised split-mouth controlled trial, Int J Oral Implantol (Berl) 12(2) (2019), 169–179.
4. TheoharidouA. PetridisH.P. TzannasK. and GarefisP., Abutment screw loosening in single-implant restorations: A systematic review, Int J Oral Maxillofac Implants 23(4) (2008), 681–690.
5. 10.1002/jbm.b.3294510.1002/jbm.b.32945 ↗
6. 10.1155/2018/295898210.1155/2018/2958982 ↗
7. 10.1111/clr.1238310.1111/clr.12383 ↗
8. 10.1590/S0103-6440201000020000610.1590/S0103-64402010000200006 ↗
9. 10.1155/2017/384908510.1155/2017/3849085 ↗
10. 10.1590/0103-644020160060410.1590/0103-6440201600604 ↗
11. MishraS.K. ChowdharyR. and KumariS., Microleakage at the different implant abutment interface: A systematic review, J Clin Diagn Res 11(6) (2017), ZE10–ZE15.
12. 10.1563/aaid-joi-D-18-0031110.1563/aaid-joi-D-18-00311 ↗
13. 10.5301/jabfm.500022410.5301/jabfm.5000224 ↗
14. 10.11607/jomi.625710.11607/jomi.6257 ↗
15. 10.1111/cid.1265110.1111/cid.12651 ↗
16. 10.1097/ID.000000000000046510.1097/ID.0000000000000465 ↗
17. 10.1111/cid.1279210.1111/cid.12792 ↗
18. BreedingL.C. DixonD.L. NelsonE.W. and TietgeJ.D., Torque required to loosen single-tooth implant abutment screws before and after simulated function, Int J Prosthodont 6 (1993), 435–439.
19. International Organization for Standardization. ISO 14801: dentistry – implants – dynamic fatigue test for endosseous dental implants. Geneva: The Organization 2015.
20. StrubJ.R. and GerdsT., Fracture strength and failure mode of five different single tooth implant-abutment combinations, Int J Prosthodont 16(2) (2003), 167–171.
21. 10.1067/mpr.2001.11539710.1067/mpr.2001.115397 ↗
22. GrossA. AbramovichI. and WeissE.I., Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study, Int J Oral Maxillofac Implants 14 (1999), 94–100.
23. SakaguchiR.L. and BorgersenS.E., Nonlinear contact analysis of preload in dental implant screws, Int J Oral Maxillofac Implants 10(3) (1995), 295–302.
24. 10.4103/1305-7456.11540710.4103/1305-7456.115407 ↗
25. 10.11607/jomi.272710.11607/jomi.2727 ↗
26. LevineR.A. ClemD. BeagleJ. GanelesJ. JohnsonP. SolnitG. , Multicenter retrospective analysis of the ITI implant system used for single tooth replacements: Results of loading for 2 or more years, Int J Oral Maxillofac Implants 14(4) (1999), 516–520.
27. 10.1016/S0022-3913(00)70016-310.1016/S0022-3913(00)70016-3 ↗
28. 10.1111/j.1600-0501.2004.01023.x10.1111/j.1600-0501.2004.01023.x ↗
29. SquierR.S. PosterW.J. and TaylorT.D., Removal torques of conical, tapered implant abutments: The effects of anodization and reduction of surface area, Int J Oral Maxillofac Implants 17(1) (2002), 24–27.
30. BinonP.P., The role of screws in implant systems, Int J Oral Maxillofac Implants 4(suppl) (1994), 48–63.
31. MerzB.R. HunebartS. and BelserU.C., Mechanics of the implant abutment connection: An 8 degree taper compared to a butt joint connection, Int J Oral Maxillofac Implants 15(4) (2000), 519–526.
32. https://www.sciencedirect.com/topics/medicine-and-dentistry/masticatory-force. Accessed on 15/07/2020.
33. 10.1563/AAID-JOI-D-10-0012710.1563/AAID-JOI-D-10-00127 ↗
34. 10.1902/jop.2011.11008710.1902/jop.2011.110087 ↗
35. 10.3390/ma1219313510.3390/ma12193135 ↗
36. ProffP. SteinmetzI. BayerleinT. DietzeS. FanghanelJ. and GedrangeT., Bacterial colonisation of interior implant threads with and without sealing, Folia Morphol (Warsz) 65(1) (2006), 75–77.
37. 10.1902/jop.2006.06010110.1902/jop.2006.060101 ↗
38. DibartS. WarbingtonM. SuM.F. and SkobeZ., In vitro evaluation of the implant-abutment bacterial seal: the locking taper system, Int J Oral Maxillofac Implants 20(5) (2005), 732–737.
39. 10.1016/j.ijom.2007.07.02610.1016/j.ijom.2007.07.026 ↗
40. 10.11607/jomi.311310.11607/jomi.3113 ↗
41. 10.11607/jomi.562910.11607/jomi.5629 ↗
42. 10.1007/s00784-011-0646-410.1007/s00784-011-0646-4 ↗
43. 10.1016/0022-3913(93)90089-710.1016/0022-3913(93)90089-7 ↗
44. 10.1034/j.1600-0501.1996.070201.x10.1034/j.1600-0501.1996.070201.x ↗