Effect of post-cam design on the kinematics and contact stress of posterior-stabilized total knee arthroplasty
Source abstract
Abstract
BACKGROUND: The post-cam mechanism in the posterior-stabilized (PS) implant plays an important role, such as durability and kinematic performances, in total knee arthroplasty (TKA). OBJECTIVE: The purpose of this study was to evaluate the difference in the kinematics and contact stress of five post-cam designs, which are flat-and-flat, curve-and-curve (concave), curve-and-curve (concave and convex), helical, and asymmetrical post-cam designs, using three-dimensional finite element models. METHODS: We designed the post-cam model with five different geometries. The kinematics, contact stress, and contact area were evaluated in the five post-cam designs under gait cycle loading conditions using the finite element method. RESULTS: There were no differences in the contact stress and area on the tibial insert in all designs. The largest internal rotation was shown in the swing phase for the helical design, and the largest tibial posterior translation was observed for the curve-and-curve (concave) design. The curve-and-curve (concave) design showed the lowest contact stress and the largest posterior tibial translation during the gait cycle. CONCLUSIONS: Considering the kinematics and contact stress, we found that the curve-and-curve (concave) design was more stable than other designs. From the results, we found the important factors of TKA implant considering stability and kinematics.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Yonsei University, , , , Republic of Korea
Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, , , , Republic of Korea
References (29)
Show source-provided references
1. The posterior stabilized condylar prosthesis: A modification of the total condylar design. Two to four-year clinical experience10.2106/00004623-198264090-00006 ↗
2. In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty10.1016/j.jbiomech.2004.02.027 ↗
3. Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: An in vitro robotic experimental investigation10.2106/00004623-200408000-00017 ↗
4. Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome: A report of 5 cases10.1016/S0883-5403(03)00333-4 ↗
5. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris10.2106/00004623-200103000-00011 ↗
6. Contact stress analysis of the conforming post-cam mechanism in posterior-stabilized total knee arthroplasty10.1016/j.arth.2007.05.023 ↗
7. Polyethylene post failure in posterior stabilized total knee arthroplasty10.1016/j.arth.2004.02.026 ↗
8. Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty10.1016/S0883-5403(03)00192-X ↗
9. Implant design influences tibial post wear damage in posterior-stabilized knees10.1007/s11999-010-1515-1 ↗
10. Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty10.1302/0301-620X.87B4.15684 ↗
11. Influence of post-cam design on stresses on posterior-stabilized tibial posts10.1097/01.blo.0000218739.76871.28 ↗
12. Post-cam design and contact stress on tibial posts in posterior-stabilized total knee prostheses: Comparison between a rounded and a squared design10.1016/j.arth.2017.07.010 ↗
13. Effect of post-cam design for normal knee joint kinematic, ligament, and quadriceps force in patient-specific posterior-stabilized total knee arthroplasty by using finite element analysis10.1155/2018/2438980 ↗
14. Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: A computational simulation study10.1007/s10856-017-5916-5 ↗
15. Tibiofemoral conformity variation offers changed kinematics and wear performance of customized posterior-stabilized total knee arthroplasty10.1007/s00167-018-5045-9 ↗
16. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis10.1016/S0021-9290(01)00179-8 ↗
17. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading10.1016/j.jbiomech.2006.07.027 ↗
18. Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics10.1115/1.1992522 ↗
19. Posterior stabilized versus cruciate retaining total knee arthroplasty designs: Conformity affects the performance reliability of the design over the patient population10.1016/j.medengphy.2015.01.008 ↗
20. Fifteen-year to 19-year follow-up of the Insall-Burstein-1 total knee arthroplasty10.1016/j.arth.2009.01.009 ↗
21. Design features of total knees for achieving normal knee motion characteristics10.1016/j.arth.2007.11.002 ↗
22. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties10.1097/01.blo.0000063121.39522.19 ↗
23. Early results of high-flex total knee arthroplasty: Comparison study at 1 year after surgery10.1007/s00167-006-0202-y ↗
24. Kinematics of the knee joint in deep flexion: A radiographic assessment10.1016/S1350-4533(98)00024-1 ↗
25. Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants10.1007/s00167-014-3227-7 ↗
26. Influence of post-cam design of posterior stabilized knee prosthesis on tibiofemoral motion during high knee flexion10.1016/j.clinbiomech.2011.04.002 ↗
27. Biomechanics of posterior-substituting total knee arthroplasty: An in vitro study10.1097/00003086-200211000-00035 ↗
28. Analysis of weight-bearing kinematics of posterior-stabilized total knee arthroplasty with novel helical post-cam design10.1016/j.arth.2011.02.007 ↗
29. The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty10.1007/s00167-018-4925-3 ↗