journal article·2024-08-16

Accuracy of an image matching technique for assessing knee alignment during the stance phase of gait using single-plane anteroposterior radiography

Koichi Kobayashi, Makoto Sakamoto, Tatsuya Soeno, Takashi Sato

Publisher page

Abstract

BACKGROUND: Accurate measurement of bone alignment of the knee during walking provides ideal clinical information for diagnosis and treatment of knee joint disorders. To bring this ideal closer to clinical reality, we developed an image matching technique to measure the three-dimensional (3D) position of bones using anteroposterior radiography during the stance phase of treadmill walking. OBJECTIVE: To develop and validate an image matching method for evaluation of 3D knee alignment using anteroposterior radiography of artificial femoral and tibial bones. METHODS: The 3D position of each bone was recovered by minimizing the difference between the projected outline and the contour of the bone in the anteroposterior radiograph. The true value of the position was measured using a 3D coordinate measuring machine. RESULTS: The mean values ± standard deviation and root mean squares (RMS) of translation errors were within −1.6 ± 2.1 mm and 2.6 mm, respectively, for femur, and 2.1 ± 1.9 mm and 2.8 mm for tibia. The mean values ± standard deviation and RMS of errors in rotation were within 0.3 ± 0.7° and 0.7°, respectively, for femur, and −0.3 ± 0.9° and 0.9°, respectively, for tibia. CONCLUSION: Our method is suitable for evaluating 3D knee alignment on anteroposterior radiography.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Lower Extremity Biomechanics and Pathologies · Knee injuries and reconstruction techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

, , Niigata University, , Japan

, Niigata Medical Center, , Japan

References (28)

Show source-provided references
1. Mechanical axis deviation of the lower limbs
2. Normal axial alignment of the lower extremities and load bearing distribution at the knee10.1097/00003086-199006000-00029 ↗
3. Postoperative alignment of total knee replacement: Its effect on survival10.1097/00003086-199402000-00021 ↗
4. Biomechanics of malalignment10.1016/S0030-5898(20)31922-2 ↗
5. Assessment of lower limb alignment: Supine fluoroscopy compared with a standing full-length radiograph10.2106/JBJS.F.01514 ↗
6. The distribution of load across the knee: A comparison of static and dynamic measurements10.1302/0301-620X.62B3.7410467 ↗
7. Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo10.1016/j.gaitpost.2005.04.012 ↗
8. A framework for the functional identification of joint centers using markerless motion capture, validation for the hip joint10.1016/j.jbiomech.2007.05.029 ↗
9. Applications and limitations of current markerless motion capture methods for clinical gait biomechanics10.7717/peerj.1299 ↗
10. Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: A pilot study10.1016/j.gaitpost.2005.12.012 ↗
11. Does close proximity robot motion tracking alter gait?10.1016/j.gaitpost.2011.07.002 ↗
12. 10.1371/journal.pone.018595210.1371/journal.pone.0185952 ↗
13. Mobile biplane X-ray imaging system for measuring 3D dynamic joint motion during overground gait10.1109/TMI.2015.2473168 ↗
14. Accuracy of mobile biplane X-ray imaging in measuring 6-degree-of-freedom patellofemoral kinematics during overground gait10.1016/j.jbiomech.2017.04.009 ↗
15. Single-leg-stance (Flamingo) radiographs to assess pelvic instability: How much motion is normal?10.2106/JBJS.G.00277 ↗
16. Single-leg-stance radiographs in the diagnosis of pelvic instability10.2106/JBJS.G.01559 ↗
17. Predictors of single-leg standing balance in individuals with medial knee osteoarthritis10.1002/acr.20046 ↗
18. Faugeras · 1993
19. Automated image registration for assessing three-dimensional alignment of entire lower extremity and implant position using bi-plane radiography10.1016/j.jbiomech.2009.08.022 ↗
20. Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy10.1007/s00776-011-0149-9 ↗
21. A simplex method for function minimization10.1093/comjnl/7.4.308 ↗
22. Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy10.1115/1.1933949 ↗
23. New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy10.1002/jor.21003 ↗
24. Three-dimensional motion analysis of the patellar component in total knee arthroplasty by the image matching method using image correlations10.1002/jor.22596 ↗
25. In vivo fluoroscopic analysis of the normal human knee10.1097/01.blo.0000062384.79828.3b ↗
26. Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions10.1007/s00167-002-0330-y ↗
27. Muscle function during gait is invariant to age when walking speed is controlled10.1016/j.gaitpost.2012.11.020 ↗
28. Knee kinematics during walking at different speeds in people who have undergone total knee replacement10.1016/j.knee.2010.04.005 ↗