journal article·2023-11-10

Topological optimization of anterior cervical plate (ACP) and its biomechanic characteristics

Peng Ye, Rongchang Fu, Zhaoyao Wang

Publisher page

Abstract

BACKGROUND: Currently, quadrilateral anterior cervical plate (QACP) is a highly prevalent ACP. OBJECTIVE: This study aims to design a novel ACP using topology optimization (TOACP). METHODS: A completed model for C1–C7 cervical segments was established and validated. QACP and TOACP cage systems were implanted within two cervical vertebrae models, respectively, and peak stresses and stress distributions for screw, plate, endplate and cage displacement were investigated under differing exercise modes. RESULTS: Stress levels upon QACP screw were maximized for over-extension exercise (243.3 MPa, 3.35% > TOACP screw). Stress level upon TOACP plate was maximized for over-extension exercise (118.2 MPa, 7.26% > QACP screw). Following QACP cage system implantation, stress on endplate and cage displacement were maximized for extension exercise, which were 27.1%, and 6.3% > TOACP cage system, respectively. Finite element analysis results revealed that topological optimization of the plate can effectively reduce screw stress, thereby enhancing cervical segments’ stability during surgery. Furthermore, stress on endplate and cage displacement decreased, indicating great potential in cage sinking and fusion enhancement. CONCLUSIONS: Topological optimization of the plate equips the cage system with advantages in clinical applications and biomechanical performance, providing alternative solutions and a theoretical basis for ACP design.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cervical and Thoracic Myelopathy · Topology Optimization in Engineering · 3D Shape Modeling and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

, Xinjiang University, , China

References (24)

Show source-provided references
1. A review of cervical spondylosis research in the last decade
2. Is stand alone PEEK cage the gold standard in multilevel anterior cervical discectomy and fusion (ACDF)? Results of a minimum 1-year follow up10.1016/j.jocn.2017.10.022 ↗
3. Anterior cervical discectomy and fusion associated complications10.1097/BRS.0b013e318154c57e ↗
4. A review of complication rates for Anterior Cervical Diskectomy and Fusion (ACDF)10.25259/SNI-191-2019 ↗
5. Screw angulation affects bone-screw stresses and bone graft load sharing in anterior cervical corpectomy fusion with a rigid screw-plate construct: a finite element model study10.1016/j.spinee.2009.08.461 ↗
6. A new multipartite plate system for anterior cervical spine surgery; finite element analysis10.1080/02688697.2017.1418290 ↗
7. Stiffness matters: Part I-the effects of plate stiffness on the biomechanics of ACDF in vitro10.1097/BRS.0000000000002643 ↗
8. Comparative studies of cervical spine anterior stabilization systems - Finite element analysis10.1016/j.clinbiomech.2015.11.016 ↗
9. Biomechanics of adjacent segments after a multilevel cervical corpectomy using anterior, posterior, and combined anterior-posterior instrumentation techniques: a finite element model study10.1016/j.spinee.2013.02.062 ↗
10. Finite element analysis of the lumbar spine with a new cage using a topology optimization method10.1016/j.medengphy.2005.03.007 ↗
11. Optimum design of an interbody implant for lumbar spine fixation10.1016/j.advengsoft.2005.03.008 ↗
12. Research progress of topology optimization technology in medical metal implants
13. High cervical disc lesions in elderly patients—presentation and surgical approach10.1007/s007010050275 ↗
14. F. Cao, R. Fu and W. Wang, Comparison of biomechanical performance of single-level triangular and quadrilateral profile anterior cervical plates, PLoS One 16(4), e0250270.10.1371/journal.pone.0250270 ↗
15. Bone ingrowth characteristics of porous tantalum and carbon fiber interbody device: an experimental study in pigs10.1016/S1529-9430(03)00407-8 ↗
16. Biomechanical comparison of different vertebral plate designs for anterior cervical discectomy and fusion using nonlinear C3-T2 multi-level spinal models10.1080/16864360.2014.962435 ↗
17. Biomechanical evaluation of adjacent segment degeneration after one or two-level anterior cervical discectomy and fusion versus cervical disc arthroplasty: a finite element analysis10.1016/j.cmpb.2020.105352 ↗
18. The cortical shell architecture of human cervical vertebral bodies10.1097/00007632-200111150-00016 ↗
19. Threaded cages for degenerative cervical disease10.1097/00003086-200201000-00005 ↗
20. Application of Taguchi method in optimization of cervical ring cage10.1016/j.jbiomech.2006.12.016 ↗
21. Straightened cervical lordosis causes stress concentration: A finite element model study10.1007/s13246-013-0182-4 ↗
22. Finite element analysis of moment-rotation relationships for human cervical spine10.1016/j.jbiomech.2004.10.029 ↗
23. Adjacent-level biomechanics after single-level anterior cervical interbody fusion with anchored zero-profile spacer versus cage-plate construct: A finite element study10.1186/s12893-020-00729-4 ↗
24. Effects of new cage profiles on the improvement in biomechanical performance of multilevel anterior cervical corpectomy and fusion: a finite element analysis10.1016/j.wneu.2019.05.037 ↗