Quantitative stereological analysis of the highly porous hydroxyapatite scaffolds using X-ray CM and SEM
Source abstract
Abstract
BACKGROUND: Material properties of the scaffolds as well as their microstructure are vital in determining in vivo cellular response. Three-dimensional (3D), highly porous scaffolds are used in tissue engineering to provide a suitable microenvironment and to support regeneration of bone. Both pore sizes and their architecture, in particular interconnection density, impact functionality of scaffold during its biomedical applications. OBJECTIVE: In this paper a comparative study of the microstructure of highly porous hydroxyapatite scaffolds produced via gelcasting of foamed slurries and replication of polyurethane sponge were carried out. METHODS: Quantitative stereological analysis of the microstructure was conducted using transmission X-ray computed microtomography (μCT) and scanning electron microscopy (SEM). Application of the X-ray microtomography allowed obtaining the 2D cross-sectional images of examined samples, and then the 3D reflection of individual samples. RESULTS: In our studies we proved that the distribution of pores in HAp bioceramics can be controlled by selection of the manufacturing method. In the case of material produced by the gelcasting method, the porosity of the samples was about ∼78 vol.%, while for the method of replication of the porous organic matrix it was higher ∼84 vol.%. Application of gelcasting method resulted in bioceramics with the macropores ranging from 95 μm to 158 μm (the modal value of 120 μm). Furthermore, micropores of size 34 μm-60 μm - so called "windows", were observed on spherical macropores surfaces. In the case of replication of polyurethane sponge only macropores from 295 μm to 337 μm (the modal value of 300 μm) were obtained. Application of μCT and SEM give more information than classical mercury intrusion porosimetry in studies of porous bioceramics. Developed materials met the criteria for porous bone substitutes. CONCLUSIONS: The results of quantitative description of microstructure allowed determining the differences between porous hydroxyapatite bioceramics obtained via replication of porous organic matrix and gelcasting of foamed slurry. The stereological analysis demonstrated, that bioceramics prepared via gelling of foamed slurry has a lower pore size and grains (1.1-1.9 μm) than the material obtained by the method of replication of polyurethane sponge (2.1-2.3 μm). Based on morphological analysis the porosity of tested materials was determined. In the case of material produce by the gelcasting, porosity of the samples was about ∼78 vol.%, while for method of replication of the porous organic matrix the porosity was higher and constituted ∼84 vol.%. Furthermore, evaluated materials varied in porosity and the pore size distribution. It was stated that the method of gelcasting resulted in hydroxyapatite bioceramics with the macropores diameter (95-158 μm), micropores so called "windows" (34-60 μm) - observed on spherical macropores walls and micropores of size 0.6 μm-1.3 μm, which were visible in sintered areas. When the method of replication of polyurethane sponge was applied only macropores from 295 μm to 337 μm were obtained. The comparable values of shape factors such as elongation, curvature of pours boundary and convexity, confirmed that macropores in both studied series had similar shape.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · biodegradable polymer synthesis and properties · Calcium Carbonate Crystallization and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Materials Science and Engineering, Warsaw University of Technology, 141 Woloska Str., 02-507 Warsaw, Poland
Faculty of Materials Science and Ceramics, AGH-University of Science and Technology, Krakow, Poland
References (35)
Show source-provided references
1. G. Tripathi and B. Basu, A porous hydroxyapatite scaffold for bone tissue engineering: Physico-mechanical and biological evaluations, Ceramic International 38 (2012).10.1016/j.ceramint.2011.07.012 ↗
2. M. Kesti, M. Müller, J. Becher, M. Schnabelrauch, M. D’Este, D. Eglin and M. Zenobi-Wong, A versatile bioink for three-dimensional printing of cellular scaffolds based on thermally and photo-triggered tandem gelation, Acta Biomaterialia 11 (2015).10.1016/j.actbio.2014.09.033 ↗
3. K.A. Hing, Bioceramics bone graft substitutes: Influence of porosity and chemistry, Int. J. Appl. Ceram. Technol. 2 (2005).10.1111/j.1744-7402.2005.02020.x ↗
4. I. Sopyan, M. Mel, S. Ramesh and K.A. Khalid, Porous hydroxyapatite for artificial bone applications, Sci. Technol. Adv. Mater. 8 (2007).10.1016/j.stam.2006.11.017 ↗
5. Z. Jaegermann and A. Ślósarczyk, Gęsta i Porowata Bioceramika Korundowa w Zastosowaniach Medycznych, Uczelniane Wydawnictwo Naukowo-Dydaktyczne, Kraków, 2007.
6. Bioceramics of calcium orthophosphates10.1016/j.biomaterials.2009.11.050 ↗
7. A. Ślósarczyk, E. Stobierska and Z. Paszkiewicz, Hydroksyapatyt jako materiał implantacyjny, Ceramics 46 (1994).
8. J.R. Jones and L.L. Hench, Regeneration of trabecular bone using porous ceramics, Curr. Opin. Solid State Mater. Sci. 7 (2003).10.1016/j.cossms.2003.09.012 ↗
9. A.J. Nevins and J.J. Cymerman, Revitalization of open apex teeth with apical periodontitis using a collagen-hydroxyapatite scaffold, Journal of Endodonthics 41(6) (2015).10.1016/j.joen.2014.12.010 ↗
10. M. Fricia, M. Passanisi, F. Salamannab, A. Parrilli, G. Giavaresi and M. Fini, Osteointegration in custom-made porous hydroxyapatite cranial implants: From reconstructive surgery to regenerative medicine, World Neurosurgery 84(2) (2015).10.1016/j.wneu.2015.03.027 ↗
11. 10.1016/j.ijadhadh.2013.09.03010.1016/j.ijadhadh.2013.09.030 ↗
12. A. Bernhardt, R. Dittrich, A. Lode, F. Despang and M. Gelinsky, Nanocrystalline spherical hydroxyapatite granules for bone repair: In vitro evaluation with osteoblast-like cells and osteoclasts, Journal of Materials Science: Materials in Medicine 24(7) (2013).10.1007/s10856-013-4933-2 ↗
13. B. Świeczko-Żurek, Biomateriały, Wydawnictwo Politechniki Gdańskiej, Gdańsk, 2009.
14. H.Y. Yasuda, S. Mahara, Y. Umakoshi, S. Imazato and S. Ebisu, Microstructure and mechanical property of synthesized hydroxyapatite prepared by colloidal process, Biomaterials 21 (2000).10.1016/S0142-9612(00)00090-9 ↗
15. K. Satou and G. Pezzotti, Rheological characteristics of slurry controlling the microstructure and compressive strength behavior of biomimetic hydroxyapatite, J. Mater. Res. 16 (2001).10.1557/JMR.2001.0027 ↗
16. 10.1016/j.molstruc.2012.10.04410.1016/j.molstruc.2012.10.044 ↗
17. A. Zima, Z. Paszkiewicz, D. Siek, J. Czechowska and A. Ślósarczyk, Study on the new bone cement based on calcium sulfate and Mg, CO3 doped hydroxyapatite, Ceramics International 38(6) (2012).10.1016/j.ceramint.2012.02.086 ↗
18. J. Czechowska, A. Zima, Z. Paszkiewicz, J. Lis and A. Ślósarczyk, Physicochemical properties and biomimetic behaviour of α-TCP-chitosan based materials, Ceramics International 40 (2014).10.1016/j.ceramint.2013.10.142 ↗
19. O. Gauthier, J.M. Bouler, E. Aguado, P. Pilet and G.A. Daculsi, Macroporous biphasic calcium phosphate ceramics: Influence of macropore diameter and macro porosity percentage on bone ingrowth, Biomaterials 19 (1998).10.1016/S0142-9612(97)00180-4 ↗
20. D.K. Groot, Hydroxyapatite as coating for implants, Interceram 4 (1987).
21. 10.1023/A:102116262600610.1023/A:1021162626006 ↗
22. 10.1007/s12034-011-0384-x10.1007/s12034-011-0384-x ↗
23. T. Livingston, P. Ducheyne and J. Garino, In vivo evaluation of a bioactive scaffold for bone tissue engineering, J. Biomed. Mater. Res. 62 (2002).10.1002/jbm.10157 ↗
24. S. Callcut and J.C. Knowles, Correlation between structure and compressive strength in a reticulated glass-reinforced hydroxyapatite foam, J. Mater. Sci. Mater. Med. 13 (2002).10.1023/A:1014718722710 ↗
25. L. Cyster, D. Grant, S. Howdle, R. Rose, D. Irvine, D. Freeman, C. Scotchford and K. Shakesheff, The influence of dispersant concentration on the pore morphology of hydroxyapatite ceramics for tissue engineering, Biomaterials 26 (2005).10.1016/j.biomaterials.2004.03.017 ↗
26. S. Deville, Freeze-casting of porous biomaterials: Structure, properties and opportunities, Materials 3 (2010).
27. A. Ślósarczyk, M. Potoczek, Z. Paszkiewicz, A. Zima, M. Lewandowska-Szumieł and A. Chróścicka, Fabrication, characteristics and biological evaluation of highly porous hydroxyapatite bioceramics, Ceramic Materials 62 (2010).
28. M. Potoczek, Gelcasting of alumina foams using agarose solutions, Ceram. Int. 34 (2008).10.1016/j.ceramint.2007.02.001 ↗
29. H. Ghomi, M.H. Fathi and H. Edris, Fabrication and characterization of bioactive glass/hydroxyapatite nanocomposite foam by gelcasting method, Ceram. Int. 37 (2011).10.1016/j.ceramint.2011.03.002 ↗
30. B. Flautre, M. Descamps, C. Delecourt, M.C. Blary and P. Hardouin, Porous HA ceramic for bone replacement: Role of the pores and interconnections – Experimental study in the rabbit, J. Mat. Sci. Mat. in Med 12 (2001).10.1023/A:1011256107282 ↗
31. J.R. Jones and L.L. Hench, Regeneration of trabecular bone using porous ceramics, Curr. Opin. Solid State Mater. Sci. 7 (2003).10.1016/j.cossms.2003.09.012 ↗
32. B. Mrzygłód, P. Matusiewicz, A. Tchórz and I. Olejarczyk-Wożeńska, Quantitative analysis of ductile iron microstructure – A comparison of selected methods for assessment, Archives of Foundry Engineering 12 (2012).10.2478/afe-2013-0060 ↗
33. K.J. Kurzydłowski and B. Ralph, Quantitative Description of Micro-Structure of Materials, CRC Press, Baton Rogue, USA, 1995.
34. A. Ślósarczyk, E. Stobierska, Z. Paszkiewicz and M. Gawlicki, Calcium phosphate materials prepared from precipitates with various calcium: Phosphorus molar ratios, Journal of the American Ceramic Society 79(10) (1996).10.1111/j.1151-2916.1996.tb09013.x ↗
35. M. Potoczek, A. Zima, Z. Paszkiewicz and A. Ślósarczyk, Manufacturing of highly porous calcium phosphate bioceramics via gel-casting using agarose, Ceramics International 35 (2009).10.1016/j.ceramint.2008.12.006 ↗