journal article·2023-01-01Open access

Three-Dimensional FEA Analysis of the Stress Distribution on Titanium and Graphene Frameworks Supported by 3 or 6-Implant Models

Shrikar R. Desai, Kiran Deepak Koulgikar, Nasser Raqe Alqhtani, Ali Robaian Alqahtani, Abdullah Saad Alqahtani, Adel Alenazi, Artak Heboyan, Gustavo V. O. Fernandes, Mohammed Mustafa

Biomimetics· Volume 8· Issue 1

Abstract

Titanium is the main component of dental implants. It is also routinely used as a framework material for implant-supported full-arch prostheses due to its low density, biocompatibility, and other mechanical properties. Remarkable mechanical properties such as lesser mass density and higher young’s modulus of graphene have gained popularity among scientists, improving the properties of biomedical implants. Thus, our study aimed to compare the outcome through the von Mises stresses generated on All-on-6 and All-on-3 implant models, as well as on the framework, and evaluate the effect of stress patterns on the crestal bone around implants in the mandible. FEA (Finite Element Analysis) study was carried out using edentulous mandible models. Four 3D FEA models with 3 and 6 implants were used (Model 1: Titanium bar-supported 6 straight implants; Model 2: Graphene bar-supported 6 straight implants; Model 3: Titanium bar-supported 3 implants with 30 degrees-tilted; Model 4: Graphene bar-supported 3 implants with 30 degrees-tilted) in order to simulate endosseous implant designs. The implant measuring 4.2 mm in diameter and 11.5 mm in length were used. The most distal implants in the 3-implant models were placed with angulation of 30 degrees; in 6 implants, they were vertically placed. All the models were analyzed for vertical and oblique axis with a single force magnitude of 100 N. In all four implant models and under loading conditions, the peak stress points were always on the neck of the most distal implant. von Mises stresses were within the normal stress range. In a conventional six-straight implant model supported by a titanium framework, the cortical stress in the region of implants was 25.27 MPa, whereas, in the graphene framework, it was 12.18 MPa. Under vertical load, there was a significant difference in the cortical stress around the tilted implants (30 degrees) in the 3-implant system of titanium and graphene frameworks, respectively, 70.31 MPa and 21.27 MPa. The graphene framework demonstrated better results than the titanium framework for the conventional six-implant system under vertical load, achieving stress of 30.09 MPa and 76.60 MPa, respectively. In the case of the 3-implant system, a significant difference in the bar stress was observed between graphene and titanium, respectively, 256.32 MPa and 180.1 MPa of bar stress. Within the limitation of this study, the peri-implant stresses were decreased using graphene framework models. Hence, it was possible to conclude that the best load-bearing capacity results were found in the graphene framework group compared to the titanium framework for All-on-6 and All-on-3 implant models, even though both materials are reliable options used as framework materials in implant-supported full-arch prostheses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Graphene and Nanomaterials Applications · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Periodontology and Implantology, HKE’S S. Nijalingappa Institute of Dental Sciences and Research, Kalaburagi 585105, India

Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia

Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia

Department of Preventive Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia

Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan 0025, Armenia

Periodontics and Oral Medicine Department, University of Michigan School of Dentistry, 1011 North University Ave, Ann Arbor, MI 48109, USA

Funding

Prince Sattam Bin Abdulaziz University project

References (50)

Show source-provided references
1. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
2. Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants
3. Load transfer in tilted implants with varying cantilever lengths in an all-on-four situation10.1111/adj.12002 ↗
4. Assessment of rehabilitation in edentulous patients treated with an immediately loaded complete fixed mandibular prosthesis supported by three implants
5. Immediate loading of 2 (all-on-2) flapless-placed mandibular implants supporting cross-arch fixed prostheses: Interim data from a 1-year follow-up prospective single cohort study
6. Effect of implant number and height on the biomechanics of full arch prosthesis10.20396/bjos.v17i0.8653837 ↗
7. Effect of metal-ceramic or all ceramic superstructure materials on stress distribution in a single implant-supported prosthesis: Threedimensional finite element analysis
8. A three-dimensional finite element study on the biomechanical simulation of various structured dental implants and their surrounding bone tissues10.1155/2016/4867402 ↗
9. Biomechanical considerations in osseointegrated prostheses10.1016/0022-3913(83)90361-X ↗
10. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials
11. Cobalt-chromium as a framework material in implant-supported fixed prostheses: A preliminary report
12. Jamari, J., Ammarullah, M.I., Santoso, G., Sugiharto, S., Supriyono, T., and van der Heide, E. (2022). In Silico Contact Pressure of Metal-on-Metal Total Hip Implant with Different Materials Subjected to Gait Loading. Metals, 12.10.3390/met12081241 ↗
13. Heboyan, A., Giudice, R.L., Kalman, L., Zafar, M.S., and Tribst, J.P.M. (2022). Stress Distribution Pattern in Zygomatic Implants Supporting Different Superstructure Materials. Materials, 15.10.3390/ma15144953 ↗
14. Finite element analysis of titanium alloy-graphene based mandible plate10.1080/10255842.2018.1555244 ↗
15. Antibacterial activity of graphite, graphite oxide, graphene oxide, and reduced graphene oxide: Membrane and oxidative stress10.1021/nn202451x ↗
16. Application of finite element analysis in implant dentistry: A review of the literature10.1067/mpr.2001.115251 ↗
17. Fem and von mises analysis of OSSTEM dental implant structural components: Evaluation of different direction dynamic loads10.2174/1874210601812010219 ↗
18. Medina-Galvez, R., Cantó-Navés, O., Marimon, X., Cerrolaza, M., Ferrer, M., and Cabratosa-Termes, J. (2021). Bone Stress Evaluation with and without Cortical Bone Using Several Dental Restorative Materials Subjected to Impact Load: A Fully 3D Transient Finite-Element Study. Materials, 14.10.3390/ma14195801 ↗
19. Brånemark Novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study10.1111/j.1708-8208.1999.tb00086.x ↗
20. Is the Fixed Mandibular 3-Implant Retained Prosthesis Safe and Predicable for Full-Arch Mandibular Prostheses? A Systematic Review
21. Fixed mandibular restorations on three early-loaded regular platform Brånemark implants10.1111/j.1708-8208.2001.tb00139.x ↗
22. Meese, C.E. (2008). Contemporary Implant Dentistry, Elsevier. [3rd ed.].
23. Biomechanical evaluation of platform switching in different implant protocols: Computed tomography-based three-dimensional finite element analysis
24. Promises, facts, and challenges for graphene in biomedical applications10.1039/C7CS00363C ↗
25. A comparative study on the effect of stress in dental implant structure using finite element analysis
26. Is graphene a promising nano-material for promoting surface modification of implants or scaffold materials in bone tissue engineering?10.1089/ten.teb.2013.0638 ↗
27. Graphene Coatings for Biomedical Implants
28. All-on-four immediate-function concept with Branemark system implants for completely edentulous maxillae: A 1-year retrospective clinical study10.1111/j.1708-8208.2005.tb00080.x ↗
29. Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: A prototyping guided 3D-FEA study10.1016/j.msec.2016.07.059 ↗
30. Haroun, F., and Ozan, O. (2021). Evaluation of Stresses on Implant, Bone, and Restorative Materials Caused by Different Opposing Arch Materials in Hybrid Prosthetic Restorations Using the All-on-4 Technique. Materials, 14.10.3390/ma14154308 ↗
31. Effect of Different Framework Materials in Implant-Supported Fixed Mandibular Prostheses: A Finite Element Analysis10.11607/jomi.7255 ↗
32. Comparative Evaluation of a Four-Implant–Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design10.11607/ijp.5369 ↗
33. Tribst, J.P.M., de Morais, D.C., de Matos, J.D.M., Lopes, G.D.R.S., Piva, A.M.D.O.D., Borges, A.L.S., Bottino, M.A., Lanzotti, A., Martorelli, M., and Ausiello, P. (2022). Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration. Dent. J., 10.10.3390/dj10010012 ↗
34. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses10.1111/j.1600-0501.2009.01712.x ↗
35. Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentulous mandible: A biomechanical study
36. Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis10.4047/jap.2015.7.3.240 ↗
37. Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths
38. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis
39. Stress distribution in single dental implant system: Three dimensional finite element analysis based on an in vitro experimental model10.1097/SCS.0000000000001977 ↗
40. Finite element analysis of provisional structures of implant-supported complete prostheses10.1563/AAID-JOI-D-11-00188 ↗
41. Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant
42. Nonlinear stress analysis of titanium implants by finite element method10.4012/dmj.27.633 ↗
43. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown10.1016/j.prosdent.2004.12.019 ↗
44. Bicortically stabilized implant load transfer
45. Biomechanics of 3-implant-supported and 4-implant-supported mandibular screw-retained prostheses: A 3D finite element analysis study10.1016/j.prosdent.2020.01.015 ↗
46. Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses
47. Ammarullah, M.I., Santoso, G., Sugiharto, S., Supriyono, T., Wibowo, D.B., Kurdi, O., Tauviqirrahman, M., and Jamari, J. (2022). Minimizing Risk of Failure from Ceramic-on-Ceramic Total Hip Prosthesis by Selecting Ceramic Materials Based on Tresca Stress. Sustainability, 14.10.3390/su142013413 ↗
48. Implant-Supported Restoration with Straight and Angled Hybrid Abutments: Digital Image Correlation and 3D-Finite Element Analysis10.1055/s-0042-1744362 ↗
49. Prosthetic Design and Restorative Material Effect on the Biomechanical Behavior of Dental Implants: Strain Gauge Analysis10.4322/bds.2022.e3380 ↗
50. Kümbüloğlu, Ö., Koyuncu, B., Yerlioğlu, G., Al-Haj Husain, N., and Özcan, M. (2022). Stress Distribution on Various Implant-Retained Bar Overdentures. Materials, 15.10.3390/ma15093248 ↗