Three-Dimensional Finite Element Analysis of Stress Distribution in Dental Implant Prosthesis and Surrounding Bone Using PEEK Abutments
Source abstract
Abstract
(1) Background: Polyetheretherketone (PEEK) has been used as an alternative to titanium in implant prosthetic systems, but its impact on stress distribution in implant systems needs to be investigated. This study aimed to compare the effect of polyetheretherketone (PEEK) and titanium abutments on implant prosthetic systems and the supporting bone using three-dimensional finite element analysis (FEA). (2) Methods: Three-dimensional finite element analysis was conducted using CATIA V5 and Abaqus V6.12 software to model mandibular first-molar implant systems with titanium and PEEK abutments. Under external loading conditions, finite element analysis was conducted for the stresses in the implant components and surrounding bones of each group. (3) Results: The implant fixture of the PEEK model exhibited the highest von Mises stress (VMS). The lowest VMS was observed in the abutment screw of the titanium model. Both implant systems demonstrated similar stress distributions and magnitudes in cortical and cancellous bones. (4) Conclusion: PEEK abutments show a similar stress distribution in the surrounding bone compared to titanium. However, PEEK absorbs the stresses within the implant system and exhibits the highest VMS values due to its low mechanical and physical properties. Therefore, PEEK abutments need improved mechanical properties for better clinical application.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan 46252, Republic of Korea
Department of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, Daegu 42472, Republic of Korea
Funding
Research Institute of Medical Science, Daegu Catholic University (2023)
References (33)
Show source-provided references
1. Velasco-Ortega, E., Del Rocío Jiménez-Martin, I., Moreno-Muñoz, J., Núñez-Márquez, E., Luis Rondón-Romero, J., Cabanillas-Balsera, D., Jiménez-Guerra, Á., Ortiz-García, I., López-López, J., and Monsalve-Guil, L. (2022). Long-term treatment outcomes of implant prostheses in partially and totally edentulous patients. Materials, 15.10.3390/ma15144910 ↗
2. Factors affecting the survival rate of dental implants: A retrospective study10.4103/jispcd.JISPCD_380_17 ↗
3. Intermediate long-term clinical performance of dental implants placed in sites with a previous early implant failure: A retrospective analysis10.1111/clr.12485 ↗
4. Lin, C.P., Shyu, Y.T., Wu, Y.L., Tsai, M.H., Chen, H.S., and Wu, A.Y. (2022). Effects of marginal bone loss progression on stress distribution in different implant-abutment connections and abutment materials: A 3D finite element analysis study. Materials, 15.10.3390/ma15175866 ↗
5. Repair of peri-implant bone loss after occlusal adjustment: A case report10.14219/jada.2014.65 ↗
6. Influence of forces on peri-implant bone10.1111/j.1600-0501.2006.01360.x ↗
7. The role of occlusion in the dental implant and peri-implant condition: A review10.2174/1874210601610010594 ↗
8. Does traumatic occlusal forces lead to peri-implant bone loss? A systematic review10.1590/1807-3107bor-2019.vol33.0069 ↗
9. Di Fiore, A., Montagner, M., Sivolella, S., Stellini, E., Yilmaz, B., and Brunello, G. (2022). Peri-implant bone loss and overload: A systematic review focusing on occlusal analysis through digital and analogic methods. J. Clin. Med., 11.10.3390/jcm11164812 ↗
10. Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments
11. Biomechanical implant treatment complications: A systematic review of clinical studies of implants with at least 1 year of functional loading
12. Biomechanical effect of a zirconia dental implant-crown system: A three-dimensional finite element analysis
13. Biomechanical behavior of implants with different diameters in relation to simulated bone loss—An in vitro study10.1007/s00784-023-05199-5 ↗
14. Khaohoen, A., Sornsuwan, T., Chaijareenont, P., Poovarodom, P., Rungsiyakull, C., and Rungsiyakull, P. (2023). Biomaterials and clinical application of dental implants in relation to bone density—A narrative review. J. Clin. Med., 12.10.3390/jcm12216924 ↗
15. Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: A 3-dimensional finite element analysis10.14347/jtd.2020.42.4.348 ↗
16. Evaluation of implant success: A review of past and present concepts10.4103/0975-7406.113310 ↗
17. Early dental implant failure: Risk factors10.1016/j.bjoms.2011.04.074 ↗
18. Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method10.1007/s10856-010-4084-7 ↗
19. Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone10.1016/j.jbiomech.2014.11.017 ↗
20. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: A cross-sectional, retrospective study in 45 patients with a 2-to 4-year follow-up using pink and white esthetic scores10.1902/jop.2009.080435 ↗
21. Effect of implant design on stress distribution: A finite element study10.1615/JLongTermEffMedImplants.2022042799 ↗
22. Influence of zirconia and titanium fixture materials on stress distribution in abutment screws: A three-dimensional finite element analysis10.14347/jtd.2021.43.2.42 ↗
23. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions10.1111/clr.13362 ↗
24. Finite element analysis of the effect of tightening torque on the connection stability of a two-piece zirconia implant system10.1155/2022/1456475 ↗
25. Pérez-Pevida, E., Brizuela-Velasco, A., Chávarri-Prado, D., Jiménez-Garrudo, A., Sánchez-Lasheras, F., Solaberrieta-Méndez, E., Diéguez-Pereira, M., Fernández-González, F.J., Dehesa-Ibarra, B., and Monticelli, F. (2016). Biomechanical consequences of the elastic properties of dental implant alloys on the supporting bone: Finite element analysis. Biomed. Res. Int., 2016.10.1155/2016/1850401 ↗
26. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant10.1016/j.prosdent.2013.10.016 ↗
27. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type10.4047/jap.2015.7.6.475 ↗
28. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants
29. Evaluation of stresses occurring on three different zirconia dental implants: Three-dimensional finite element analysis
30. Mohamed, M., Pisavadia, H., and Westover, L. (2021). A finite element model for evaluating the effectiveness of the Advanced System for Implant Stability Testing (ASIST). J. Biomech., 124.10.1016/j.jbiomech.2021.110570 ↗
31. Three-dimensional finite element analysis of anterior single implant-supported prostheses with different bone anchorages10.1155/2015/321528 ↗
32. Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: A 3-dimensional finite element analysis10.4047/jap.2021.13.6.396 ↗
33. Licausi, M.P., Muñoz, A.I., Borrás, V.A., and Espallargas, N. (2015). Tribocorrosion mechanisms of Ti6Al4V in artificial saliva by zero-resistance ammetry (ZRA) technique. J. Bio Tribo Corros., 1.10.1007/s40735-015-0008-x ↗