Individualized Ophthalmic Exoplants by Means of Reverse Engineering and 3D Printing Technologies for Treating High Myopia Complications with Macular Buckles
Source abstract
Abstract
Myopic macular foveoschisis maculopathy is an eye disease that is treated, in most cases, with surgical intervention, in which a macular buckle is applied to restore eye anatomy and functionality. A macular buckle is a type of exoplant that comes in various designs and sizes. Often, they are difficult to apply or they do not fit properly in the eye geometry since they have a generic form. In this work, the effort to develop the most suitable tailor-made macular buckle for each individual patient for treating myopic traction maculopathy is studied. Pattern recognition techniques are applied to the patient’s Computed Tomography (CT) data to develop the exact 3D geometry of the eye. Using this 3D geometry, the trajectory of the buckle is fitted and the buckle is formed, which is then 3D-printed with biocompatible polymer materials. It is expected that the power of technology will be used to activate the most precise approach for each individual patient. Considering the possible complications and technical difficulties of other surgical methods, the customized macular buckle is an appropriate, easy-to-use, and most precise piece of medical equipment for the treatment of myopic traction maculopathy.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Retinal and Macular Surgery · Retinal Diseases and Treatments · Intraocular Surgery and Lenses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ophthalmology Department, General Hospital Venizeleio, 44 Knossou Avenue, 71409 Heraklion, Greece
Mechanical Engineering Department, Hellenic Mediterranean University, Estavromenos, 71004 Heraklion, Greece
Department of Materials Science and Technology, University of Crete, Vassilika, Voutes, 70013 Heraklion, Greece
References (19)
Show source-provided references
1. Prevalence and characteristics of foveal retinal detachment without mac- ular hole in high myopia10.1016/S0002-9394(02)01937-2 ↗
2. Long-term fol- low-up of high myopic foveoschisis: Natural course and surgi- cal outcome10.1016/j.ajo.2006.10.053 ↗
3. Foveal retinoschisis and retinal detachment in severely myopic eyes with posterior staphyloma10.1016/S0002-9394(99)00186-5 ↗
4. Vitreous surgery for highly myopic eyes with foveal detachment and retinoschisis10.1016/S0161-6420(03)00714-0 ↗
5. Natural course of macular retinoschisis in highly myopic eyes without macular hole or retinal detachment10.1016/j.ajo.2006.03.048 ↗
6. Progression from macular retinoschisis to retinal detachment in highly myopic eyes is associated with outer lamellar hole formation10.1136/bjo.2007.131359 ↗
7. Foveoschisis after vitrectomy for myopic macular hole with secondary retinal detachment10.1038/eye.2008.405 ↗
8. Macular retinoschisis in highly myopic eyes10.1016/S0002-9394(02)01394-6 ↗
9. Posterior vitreous detachment and macular hole formation in myopic foveoschisis10.1016/j.ajo.2004.06.064 ↗
10. Pathologic findings in pathologic myopia10.1097/00006982-199212020-00009 ↗
11. Surgical management of retinal detachment associated with myopic macular hole: Anatomic and functional status of the macula10.1016/S0002-9394(03)00186-7 ↗
12. The macular buckling procedure in the treatment of retinal detachment in highly my-opic eyes with macular hole and posterior staphyloma: Mean follow-up of 15 years10.1097/00006982-200504000-00006 ↗
13. Scleral buckling with macular plombe for eyes with myopic macular retinoschisis and retinal detachment without macular hole10.1016/j.ajo.2006.04.046 ↗
14. Vitrectomy and internal limiting membrane peeling for myopic foveoschisis
15. Indications and Results of a New L-Shaped Macular Buckle to Support a Posterior Staphyloma in High Myopia10.1097/IAE.0000000000000613 ↗
16. Ng, E.Y., Tan, J.H., Acharya, U.R., and Suri, J.S. (2012). Human Eye Imaging and Modeling, Taylor and Francis Group; CRC Press.10.1201/b12081 ↗
17. Illuminated Ando Plombe for Optimal Positioning in Highly Myopic Eyes With Vitreoretinal Diseases Secondary to Posterior Staphyloma10.1001/jamaophthalmol.2013.4558 ↗
18. Disc-to-Macula Distance to Disc-Diameter Ratio for Optic Disc Size Estimation10.1097/00061198-200210000-00004 ↗
19. Jeffrey, M.T. (2019). Chapter 8—Biocompatibility of PEEK Polymers. PEEK Biomaterials Handbook, A Volume in Plastics Design Library, Elsevier Inc.