journal article·2025-01-24Open access

A Finite Element Study of Simulated Fusion in an L4-L5 Model: Influence of the Combination of Materials in the Screw-and-Rod Fixation System on Reproducing Natural Bone Behavior

Mario Ceddia, Luciano Lamberti, Bartolomeo Trentadue

Biomimetics· Volume 10· Issue 2

Abstract

The mechanical properties of materials for spinal fixation can significantly affect spinal surgical outcomes. Traditional materials such as titanium exhibit high stiffness, which can lead to stress shielding and adjacent segment degeneration. This study investigates the biomechanical performance of titanium and PEEK (polyetheretherketone) in spinal fixation using finite element analysis, through the evaluation of the Shielding Strength Factor (SSF). Methods: A three-dimensional finite element analysis (FEA) model of an L4/L5 functional spinal unit was developed to simulate the mechanical behavior of three fixation systems: titanium screws and rods (model A), titanium screws with PEEK rods (model B), and PEEK screws and rods (model C). The analysis evaluated stress distribution and load transfer under physiological conditions, in comparison with the intact spine (baseline model). Results: The analysis showed that titanium fixation systems resulted in higher stress shielding effects, with a significant difference in stress distribution compared to PEEK. The maximum stress recorded in the neutral position was 24.145 MPa for PEEK, indicating better biomechanical compatibility. Conclusions: The results suggest that PEEK may be an attractive alternative to titanium for spinal fixation, promoting more healthy load transfer and minimizing the risk of stress shielding complications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanics, Mathematics and Management, Polytechnic of Bari, 70125 Bari, Italy

References (76)

Show source-provided references
1. Beyond the pedicle screw—A patent review10.1007/s00586-022-07193-z ↗
2. Impact of screw diameter and length on pedicle screw fixation strength in osteoporotic vertebrae: A finite element analysis10.31616/asj.2020.0353 ↗
3. Effect of pedicle screw diameter on screw fixation efficacy in human osteoporotic thoracic vertebrae10.1016/j.jbiomech.2017.10.009 ↗
4. Combined pedicle screw fixation at the fracture vertebrae versus conventional method for thoracolumbar fractures: A meta-analysis10.1016/j.ijsu.2018.03.002 ↗
5. Occupational hazard of fluoroscopy: An invisible threat to orthopaedic surgeons
6. How should radiation exposure be handled in fluoroscopy-guided endoscopic procedures in the field of gastroenterology?10.1111/den.14208 ↗
7. Fluoroscopy and MRI induced skin injuries: A review of diagnostic, management, and preventative principles10.1007/s40134-020-00376-w ↗
8. Pedicle screw loosening: The value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgery10.1186/s13018-018-1046-0 ↗
9. Pedicle screw loosening in dynamic stabilization: Incidence, risk, and outcome in 126 patients10.3171/2011.7.FOCUS11125 ↗
10. The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure10.1016/j.actbio.2023.11.011 ↗
11. Young’s modulus of trabecular bone at the tissue level: A review10.1016/j.actbio.2018.08.001 ↗
12. Evaluation of rotational stability and stress shielding of a stem optimized for hip replacements—A finite element study10.3390/prosthesis5030048 ↗
13. Ceddia, M., Trentadue, B., De Giosa, G., and Solarino, G. (2023). Topology optimization of a femoral stem in titanium and carbon to reduce stress shielding with the FEM method. J. Compos. Sci., 7.10.20944/preprints202307.0758.v1 ↗
14. Ceddia, M., Solarino, G., Tucci, M., Lamberti, L., and Trentadue, B. (2024). Stress analysis of tibial bone using three different materials for bone fixation plates. J. Compos. Sci., 8.10.3390/jcs8090334 ↗
15. Finite-Element Analysis Study Comparing Titanium and Polyetheretherketone Caps in a Conometric Connection between Implant and Prosthesis10.1002/adem.202400198 ↗
16. Ceddia, M., Lamberti, L., and Trentadue, B. (2024). FEA Comparison of the Mechanical Behavior of Three Dental Crown Materials: Enamel, Ceramic, and Zirconia. Materials, 17.10.3390/ma17030673 ↗
17. Cipollina, A., Ceddia, M., Di Pietro, N., Inchingolo, F., Tumedei, M., Romasco, T., Piattelli, A., Specchiulli, A., and Trentadue, B. (2023). Finite element analysis (FEA) of a premaxillary device: A new type of subperiosteal implant to treat severe atrophy of the maxilla. Biomimetics, 8.10.20944/preprints202306.1150.v1 ↗
18. Ceddia, M., Romasco, T., De Bortoli, N., Mello, B.F., Piattelli, A., Mijiritsky, E., Di Pietro, N., and Trentadue, B. (2024). Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications. Materials, 17.10.2139/ssrn.4876911 ↗
19. Additive manufacturing for metallic spinal implants: A systematic review10.1016/j.stlm.2021.100021 ↗
20. Mechanical performance of porous biomimetic intervertebral body fusion devices: An in vitro biomechanical study10.1186/s13018-023-03556-4 ↗
21. A review on biological and biomimetic materials and their applications10.1007/s00339-020-03633-z ↗
22. Advances in research for biomimetic materials10.4028/www.scientific.net/AMR.1149.28 ↗
23. Adjacent segment disease after single segment posterior lumbar interbody fusion for degenerative spondylolisthesis: Minimum 10 years follow-up10.1097/BRS.0000000000002710 ↗
24. Osteogenesis of 3D printed porous Ti6Al4V implants with different pore sizes10.1016/j.jmbbm.2018.04.010 ↗
25. Influence of pedicle screw thread width and recovery time after surgery on fixation strength10.1515/cdbme-2021-2192 ↗
26. Polyetheretherketone (PEEK) rods for lumbar fusion: A systematic review and meta-analysis10.14444/5027 ↗
27. Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: A systematic review10.1007/s10143-016-0763-2 ↗
28. Papathanasiou, I., Kamposiora, P., Papavasiliou, G., and Ferrari, M. (2020). The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health, 20.10.1186/s12903-020-01202-7 ↗
29. Developments of PEEK (Polyetheretherketone) as a biomedical material: A focused review10.1016/j.eurpolymj.2021.110295 ↗
30. Hybrid composite pedicle screw-finite element modelling with parametric optimization10.1016/j.imu.2020.100290 ↗
31. Finite element analysis comparing a PEEK posterior fixation device versus pedicle screws for lumbar fusion10.1186/s13018-023-04349-5 ↗
32. Kurtz, S.M. (2019). PEEK Biomaterials Handbook, William Andrew.
33. The applications of polyether-ether-ketone (peek) in dentistry: Systematic review
34. Naoum, S., Vasiliadis, A.V., Koutserimpas, C., Mylonakis, N., Kotsapas, M., and Katakalos, K. (2021). Finite Element Method for the Evaluation of the Human Spine: A Literature Overview. J. Funct. Biomater., 12.10.3390/jfb12030043 ↗
35. A biomechanical finite element study to assess the suitability of implantation on lumbar vertebrae L4-L510.1177/09544062231156101 ↗
36. Gornet, M.F., Chan, F.W., Coleman, J.C., Murrell, B., Nockels, R.P., Taylor, B.A., Lanman, T.H., and Ochoa, J.A. (2011). Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs. J. Biomech. Eng., 133.10.1115/1.4004862 ↗
37. Biomechanical evaluation of pedicle screw fixation system in spinal adjacent levels using polyetheretherketone, carbon-fiber-reinforced polyetheretherketone, and traditional titanium as rod materials10.1016/j.compositesb.2017.07.052 ↗
38. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: Experimental and finite-element analysis10.1007/s00586-005-0915-5 ↗
39. Mechanical and thermal stress evaluation of PEEK prefabricated post with different head design in endodontically treated tooth: 3D-finite element analysis10.4012/dmj.2020-053 ↗
40. Lim, K.M., Park, T.H., Lee, S.J., and Park, S.J. (2019). Design and biomechanical verification of additive manufactured composite spinal cage composed of porous titanium cover and PEEK body. Appl. Sci., 9.10.3390/app9204258 ↗
41. Rafie, A., and Haghpanahi, M. (2022, January 21–22). Biomechanical Study of Fused Lumbar Spine Comparing Ti and PEEK as Connecting Rod Considering Bone Degeneracy Using FEA. Proceedings of the 2022 29th National and 7th International Iranian Conference on Biomedical Engineering (ICBME), Tehran, Iran.10.1109/ICBME57741.2022.10053034 ↗
42. Association between lumbar spine sagittal alignment and L4-L5 disc degeneration among asymptomatic young adults10.1097/BRS.0000000000001568 ↗
43. Biomechanical effect of L4–L5 intervertebral disc degeneration on the lower lumbar spine: A finite element study10.1111/os.12703 ↗
44. Sun, D., Liu, P., Cheng, J., Ma, Z., Liu, J., and Qin, T. (2017). Correlation between intervertebral disc degeneration, paraspinal muscle atrophy, and lumbar facet joints degeneration in patients with lumbar disc herniation. BMC Musculoskelet. Disord., 18.10.1186/s12891-017-1522-4 ↗
45. Correlation between Lumbar Malposition and Disc Herniation in Lumbar Disc Herniation Patients: Focused on L4-L5, L5-S110.18325/jkmr.2023.33.4.185 ↗
46. Density and mechanical properties of vertebral trabecular bone—A review
47. Relationships among bone morphological parameters and mechanical properties of cadaveric human vertebral cancellous bone
48. Mechanical properties of adult vertebral cancellous bone: Correlation with collagen intermolecular cross-links10.1359/jbmr.2002.17.9.1621 ↗
49. Biomechanical behavior of bone tissue in spine instrumentation. Comportamiento biomecánico de tejido óseo en fijaciones de columna
50. A comparative study on the mechanical behavior of intervertebral disc using hyperelastic finite element model10.3233/THC-171320 ↗
51. Effective modulus of the human intervertebral disc and its effect on vertebral bone stress10.1016/j.jbiomech.2016.02.045 ↗
52. Li, J., Cao, S., and Zhao, B. (2024). Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: A finite element analysis. BMC Surg., 24.10.1186/s12893-024-02462-8 ↗
53. The biomechanical effects of Ti versus PEEK used in the PLIF surgery on lumbar spine: A finite element analysis10.1080/10255842.2020.1869219 ↗
54. Son, D.M., Lee, S.B., Lee, S.J., Park, T.H., Jang, J.E., Jeong, S.J., Kang, Y.M., and Lee, B.H. (2022). Biomechanical Comparison of Multilevel Lumbar Instrumented Fusions in Adult Spinal Deformity According to the Upper and Lower Fusion Levels: A Finite Element Analysis. BioMed Res. Int., 2022.10.1155/2022/2534350 ↗
55. Kang, S., Park, C.-H., Jung, H., Lee, S., Min, Y.-S., Kim, C.-H., Cho, M., Jung, G.-H., Kim, D.-H., and Kim, K.-T. (2022). Analysis of the physiological load on lumbar vertebrae in patients with osteoporosis: A finite-element study. Sci. Rep., 12.10.1038/s41598-022-15241-3 ↗
56. A cell-based smoothed finite element method (CS-FEM) for three-dimensional incompressible laminar flows using mixed wedge-hexahedral element10.1016/j.enganabound.2021.09.008 ↗
57. Ceddia, M., Solarino, G., Giannini, G., De Giosa, G., Tucci, M., and Trentadue, B. (2024). A Finite Element Analysis Study of Influence of Femoral Stem Material in Stress Shielding in a Model of Uncemented Total Hip Arthroplasty: Ti-6Al-4V versus Carbon Fibre-Reinforced PEEK Composite. J. Compos. Sci., 8.10.3390/jcs8070254 ↗
58. Ceddia, M., Solarino, G., Cassano, G.D., and Trentadue, B. (2023). Finite Element Study on Stability in the Femoral Neck and Head Connection to Varying Geometric Parameters with the Relates Implications on the Effect of Wear. J. Compos. Sci., 7.10.20944/preprints202307.0806.v1 ↗
59. Boccaccio, A., Lamberti, L., Santoro, L., and Trentadue, B. (2023). Mechanical characterization of soft membranes with one-shot projection moiré and metaheuristic optimization. Appl. Sci., 13.10.3390/app13137758 ↗
60. Callea, C., Ceddia, M., Piattelli, A., Specchiulli, A., and Trentadue, B. (2023). Finite element analysis (FEA) for a different type of cono-in dental implant. Appl. Sci., 13.10.3390/app13095313 ↗
61. Risk factors for adjacent segment disease requiring reoperation after posterior lumbar interbody fusion with screw fixation: Focus on paraspinal muscle, facet joint, and disc degeneration10.1007/s00701-021-05073-x ↗
62. Demographic, clinical, and operative risk factors associated with postoperative adjacent segment disease in patients undergoing lumbar spine fusions: A systematic review and meta-analysis10.1016/j.spinee.2021.12.002 ↗
63. Risk factors for adjacent segment disease after posterior lumbar interbody fusion and efficacy of simultaneous decompression surgery for symptomatic adjacent segment disease
64. Atlantoaxial transarticular screw fixation: A review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients10.3171/spi.2005.2.2.0164 ↗
65. Comparison between anterior cervical discectomy fusion and cervical corpectomy fusion using titanium cages for reconstruction: Analysis of outcome and long-term follow-up10.1007/s00586-009-0897-9 ↗
66. Rationale for interbody fusion with threaded titanium cages at cervical and lumbar levels. Results on 357 cases10.1007/s007010050453 ↗
67. PEEK rod systems for the spine10.1007/s00590-014-1421-4 ↗
68. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation10.1016/j.spinee.2008.08.002 ↗
69. Flexible stabilisation of the degenerative lumbar spine using PEEK rods10.1155/2016/7369409 ↗
70. In vitro comparison of Dynesys, PEEK, and titanium constructs in the lumbar spine10.1155/2015/895931 ↗
71. Oikonomidis, S., Greven, J., Bredow, J., Eh, M., Prescher, A., Fischer, H., Thüring, J., Eysel, P., Hildebrand, F., and Kobbe, P. (2020). Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model. Clin. Biomech., 80.10.1016/j.clinbiomech.2020.105153 ↗
72. The use of carbon fiber/polyetheretherketone (CF/PEEK) in pedicle screw fixation for spinal neoplasms—Potential advantages in postoperative imaging and radiotherapy planning10.21037/jss-23-93 ↗
73. Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: A preliminary report10.1007/s00701-013-1772-3 ↗
74. Carbon fiber–reinforced PEEK versus titanium implants: An in vitro comparison of susceptibility artifacts in CT and MR imaging10.1007/s10143-020-01384-2 ↗
75. Biomechanical analysis between PEEK and titanium screw-rods spinal construct subjected to fatigue loading
76. The effect of position and different size of radial hole on performance of cannulated pedicle screw10.1051/matecconf/201710813001 ↗