Hybrid BCI for Meal-Assist Robot Using Dry-Type EEG and Pupillary Light Reflex
Source abstract
Abstract
Brain–computer interface (BCI)-based assistive technologies enable intuitive and efficient user interaction, significantly enhancing the independence and quality of life of elderly and disabled individuals. Although existing wet EEG-based systems report high accuracy, they suffer from limited practicality. This study presents a hybrid BCI system combining dry-type EEG-based flash visual-evoked potentials (FVEP) and pupillary light reflex (PLR) designed to control an LED-based meal-assist robot. The hybrid system integrates dry-type EEG and eyewear-type infrared cameras, addressing the preparation challenges of wet electrodes, while maintaining practical usability and high classification performance. Offline experiments demonstrated an average accuracy of 88.59% and an information transfer rate (ITR) of 18.23 bit/min across the four target classifications. Real-time implementation uses PLR triggers to initiate the meal cycle and EMG triggers to detect chewing, indicating the completion of the cycle. These features allow intuitive and efficient operation of the meal-assist robot. This study advances the BCI-based assistive technologies by introducing a hybrid system optimized for real-world applications. The successful integration of the FVEP and PLR in a meal-assisted robot demonstrates the potential for robust and user-friendly solutions that empower the users with autonomy and dignity in their daily activities.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: EEG and Brain-Computer Interfaces · Neuroscience and Neural Engineering · Gaze Tracking and Assistive Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Bionics Research Center, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
Next-Generation Mechanical Design Laboratory, Korea University, Seoul 02841, Republic of Korea
Department of HY-KIST Bio-Convergence, Hanyang University, Seoul 04763, Republic of Korea
Funding
National Research Foundation of Korea (NRF)
References (59)
Show source-provided references
1. World Health Organization (2024, December 22). Disability and Health. Available online: https://www.who.int/health-topics/disability#tab=tab_1.
2. Development of a comprehensive design guideline to evaluate the user experiences of meal-assistance robots considering human–machine social interactions10.1080/10447318.2021.2009672 ↗
3. Rashid, M., Sulaiman, N., P P Abdul Majeed, A., Musa, R.M., Ab Nasir, A.F., Bari, B.S., and Khatun, S. (2020). Current status, challenges, and possible solutions of EEG-based brain–computer interface: A comprehensive review. Front. Neurorobot., 14.10.3389/fnbot.2020.00025 ↗
4. EEG-Based Brain-Computer Interfaces (BCIs): A Survey of Recent Studies on Signal Sensing Technologies and Computational Intelligence Approaches and Their Applications10.1109/TCBB.2021.3052811 ↗
5. Tao, L., Cao, T., Wang, Q., Liu, D., Bai, O., and Sun, J. (2023). Application of self-adaptive multiple-kernel extreme learning machine to improve MI-BCI performance of subjects with BCI illiteracy. Biomed. Signal Process. Control, 79.10.1016/j.bspc.2022.104183 ↗
6. Improving performance of motor imagery-based brain–computer interface in poorly performing subjects using a hybrid-imagery method utilizing combined motor and somatosensory activity10.1109/TNSRE.2023.3237583 ↗
7. Bai, X., Li, M., Qi, S., Ng, A.C.M., Ng, T., and Qian, W. (2023). A hybrid P300-SSVEP brain–computer interface speller with a frequency enhanced row and column paradigm. Front. Neurosci., 17.10.3389/fnins.2023.1133933 ↗
8. RSVP-based BCI for inconspicuous targets: Detection, localization, and modulation of attention10.1088/1741-2552/ad658e ↗
9. Mai, X., Ai, J., Ji, M., Zhu, X., and Meng, J. (2024). A hybrid BCI combining SSVEP and EOG and its application for continuous wheelchair control. Biomed. Signal Process. Control, 88.10.1016/j.bspc.2023.105530 ↗
10. Brain-controlled, AR-based Home automation system using SSVEP-based brain–computer interface and EOG-based eye tracker: A feasibility study for the elderly end User10.1109/TNSRE.2022.3228124 ↗
11. Brain computer interface using flash onset and offset visual evoked potentials10.1016/j.clinph.2007.11.013 ↗
12. Ha, J., Park, S., Im, C.-H., and Kim, L. (2021). A hybrid brain–computer interface for real-life meal-assist robot control. Sensors, 21.10.3390/s21134578 ↗
13. Mounesi Rad, S., and Danishvar, S. (2024). Emotion recognition using EEG signals through the design of a dry electrode based on the combination of Type 2 fuzzy sets and deep convolutional graph networks. Biomimetics, 9.10.3390/biomimetics9090562 ↗
14. Polyvinyl alcohol/polyacrylamide double-network hydrogel-based semi-dry electrodes for robust electroencephalography recording at hairy scalp for noninvasive brain–computer interfaces10.1088/1741-2552/acc098 ↗
15. Dispersed carbon nanotube paper tape loaded poly (3,4-ethylenedioxythiophene) for flexible supercapacitors with significantly enhanced energy storage performance and deformation durability10.1016/j.jpowsour.2024.235684 ↗
16. Mannan, M.M., Kamran, M.A., Kang, S., Choi, H.S., and Jeong, M.Y. (2020). A Hybrid Speller Design Using Eye Tracking and SSVEP Brain-Computer Interface. Sensors, 20.10.3390/s20030891 ↗
17. Designing light stimulation for a pupillary–computer interface using binary code10.1016/j.ifacsc.2024.100246 ↗
18. Muto, Y., Miyoshi, H., and Kaneko, H. (2020). Eye-gaze information input based on pupillary response to visual stimulus with luminance modulation. PLoS ONE, 15.10.1371/journal.pone.0226991 ↗
19. Kothe, C., Medine, D., and Grivich, M. (2024, December 23). Lab Streaming Layer 2014. Available online: https://github.com/labstreaminglayer/pylsl.
20. The extension of multivariate synchronization index method for SSVEP-based BCI10.1016/j.neucom.2017.03.082 ↗
21. Kassner, M., Patera, W., and Bulling, A. (2014, January 13–17). Pupil: An open source platform for pervasive eye tracking and mobile gaze-based interaction. Proceedings of the 2014 ACM International Joint Conference on Pervasive and Ubiquitous Computing, Seattle, WA, USA.10.1145/2638728.2641695 ↗
22. Swirski, L., Bulling, A., and Dodgson, N. (2012, January 28–30). Robust real-time pupil tracking in highly off-axis images. Proceedings of the Symposium on Eye Tracking Research and Applications, ACM 2012, Santa Barbara, CA, USA.10.1145/2168556.2168585 ↗
23. Applications of the generalized Morse wavelets: A review10.1109/ACCESS.2022.3232729 ↗
24. Ismail, A.R., Jovanovic, S., Ramzan, N., and Rabah, H. (2023). Ecg classification using an optimal temporal convolutional network for remote health monitoring. Sensors, 23.10.3390/s23031697 ↗
25. Abe, M., Miyao, J., and Kurita, T. (2020, January 19–24). Adaptive neuron-wise discriminant criterion and adaptive center loss at hidden layer for deep convolutional neural network. Proceedings of the International Joint Conference on Neural Networks (IJCNN), Glasgow, UK.10.1109/IJCNN48605.2020.9206697 ↗
26. SVM parameter optimization using grid search and genetic algorithm to improve classification performance
27. Repeated holdout validation for weighted quantile sum regression10.1016/j.mex.2019.11.008 ↗
28. Estimating classification error rate: Repeated cross-validation, repeated hold-out and bootstrap10.1016/j.csda.2009.04.009 ↗
29. Review of Riemannian distances and divergences, applied to SSVEP-based BCI10.1007/s12021-020-09473-9 ↗
30. A direct demonstration of cortical LTP in humans: A combined TMS/EEG study10.1016/j.brainresbull.2005.11.003 ↗
31. Noisy network attractor models for transitions between EEG microstates10.1186/s13408-020-00100-0 ↗
32. The Riemannian potato field: A tool for online signal quality index of EEG10.1109/TNSRE.2019.2893113 ↗
33. A differential geometric approach to the geometric mean of symmetric positive-definite matrices10.1137/S0895479803436937 ↗
34. (2024, December 24). NT Robot. Available online: http://www.ntrobot.net/shop_contents/myboard_read.htm?load_type=&page_idx=0&tag_on=&h_search_c=0&h_search_v=&me_popup=&myboard_code=product&page_limit=12&idx=46206&page=1&category_idx=.
35. A new method for non-parametric multivariate analysis of variance
36. Anderson, M.J. (2014). Permutational multivariate analysis of variance (PERMANOVA). Wiley Statsref: Statistics Reference Online, Wiley Online Library.
37. Riemannian geometry for EEG-based brain–computer interfaces; A primer and a review10.1080/2326263X.2017.1297192 ↗
38. A discriminative SPD feature learning approach on Riemannian manifolds for EEG classification10.1016/j.patcog.2023.109751 ↗
39. EEG electric field topography is stable during moments of high field strength10.1007/s10548-020-00780-7 ↗
40. Multiclass brain–computer interface classification by Riemannian geometry10.1109/TBME.2011.2172210 ↗
41. Saifutdinova, E., Congedo, M., Dudysova, D., Lhotska, L., Koprivova, J., and Gerla, V. (2019). An unsupervised multichannel artifact detection method for sleep EEG based on Riemannian geometry. Sensors, 19.10.3390/s19030602 ↗
42. A multi-class EEG-based BCI classification using multivariate empirical mode decomposition based filtering and Riemannian geometry10.1016/j.eswa.2017.11.007 ↗
43. A flexible, stable, semi-dry electrode with low impedance for electroencephalography recording10.1039/D4RA05560H ↗
44. Wearable gold–graphene dry electrode-based headband for effective brain–computer interface applications10.1039/D4TC00574K ↗
45. Sheeraz, M., Saadeh, W., and Altaf, M.A.B. (2023, January 21–25). A wearable EEG acquisition device with flexible silver ink screen printed dry sensors. Proceedings of the IEEE International Symposium on Circuits and Systems (ISCAS), Monterey, CA, USA.10.1109/ISCAS46773.2023.10181812 ↗
46. Hossain, K.M., Islam, M.A., Hossain, S., Nijholt, A., and Ahad, M.A.R. (2022). Status of deep learning for EEG-based brain–computer interface applications. Front. Comput. Neurosci., 16.10.3389/fncom.2022.1006763 ↗
47. High performance clean versus artifact dry electrode EEG data classification using Convolutional Neural Network transfer learning10.1016/j.cnp.2023.04.002 ↗
48. Evaluation of consumer-grade wireless EEG systems for brain–computer interface applications10.1007/s13534-024-00416-w ↗
49. Perera, C.J., Naotunna, I., Sadaruwan, C., Gopura, R.A.R.C., and Lalitharatne, T.D. (2016, January 9–12). SSVEP based BMI for a meal assistance robot. Proceedings of the IEEE International Conference on Systems, Man, and Cybernetics (SMC), Budapest, Hungary.10.1109/SMC.2016.7844580 ↗
50. Perera, C.J., Lalitharatne, T.D., and Kiguchi, K. (June, January 29). EEG-controlled meal assistance robot with camera-based automatic mouth position tracking and mouth open detection. Proceedings of the IEEE International Conference on Robotics and Automation (ICRA), Singapore.
51. EEGNet: A compact convolutional neural network for EEG-based brain–computer interfaces10.1088/1741-2552/aace8c ↗
52. Deep learning with convolutional neural networks for EEG decoding and visualization10.1002/hbm.23730 ↗
53. Deep learning-based electroencephalography analysis: A systematic review10.1088/1741-2552/ab260c ↗
54. Park, S., and Whang, M. (2018). Infrared camera-based non-contact measurement of brain activity from pupillary rhythms. Front. Physiol., 9.10.3389/fphys.2018.01400 ↗
55. Petersen, P. (2006). Riemannian Geometry, Springer.
56. Xu, J., Markham, A., Meunier, A., Raggam, P., and Grosse-Wentrup, M. (2021, January 17–20). Distance covariance: A nonlinear extension of Riemannian geometry for EEG-based brain-computer interfacing. Proceedings of the 2021 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Melbourne, Australia.10.1109/SMC52423.2021.9658876 ↗
57. Log-determinant divergences revisited: Alpha-beta and gamma log-det divergences10.3390/e17052988 ↗
58. Revisiting Riemannian geome-try-based EEG decoding through approximate joint diagonalization10.1088/1741-2552/aca4fc ↗
59. Wavelet analysis of neuroelectric waveforms: A conceptual tutorial10.1006/brln.1998.2024 ↗