Virtual Quartz Crystal Microbalance: Bioinspired Resonant Frequency Tracking
Source abstract
Abstract
The reference acoustic properties of the quartz crystal used as a resonator are ensured by its high-quality factor (Q-factor). The microbalance of the quartz crystal (QCM) exploits the bulk acoustic properties of the quartz crystal. Turning a network analyzer or impedance analyzer into a QCM with a decent measurement rate is a challenge. The use of a virtual instrument to implement an impedance analyzer (VIA) provides greater flexibility to the virtual QCM. In this paper, VIA’s flexibility is exploited for the experimental evaluation of conventional scanning procedures and the influence of associated parameters, in order to identify elements that can lead to a limitation of the performance of a virtual QCM. The results of the experimental investigation justify the use of an innovative and optimized bioinspired scanning procedure to effectively track the serial resonance frequency of the QCM sensor. Variable-resolution spatial sampling of the human retina and the ability of the eye to refocus on the area of interest is the source of bioinspiration for achieving an adaptive virtual QCM. The design methodology and physics are described in detail, and the experimental investigations demonstrate the effectiveness of the proposed bioinspired scanning procedure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Acoustic Wave Resonator Technologies · Gas Sensing Nanomaterials and Sensors · Mechanical and Optical Resonators
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Physics Department, Babes-Bolyai University, 400084 Cluj-Napoca, Romania
References (49)
Show source-provided references
1. Tool Use by Spiders: Stone Selection and Placement by Corolla Spiders Ariadna (Segestriidae) of the Namib Desert10.1111/j.1439-0310.1995.tb00357.x ↗
2. Nature driven spider silk as high energy conversion efficient bio-piezoelectric nanogenerator10.1016/j.nanoen.2018.05.014 ↗
3. Recent progress in silk fibroin-based flexible electronics10.1038/s41378-021-00261-2 ↗
4. Development, via compression, of electric polarization in hemihedral crystals with inclined faces
5. Who knew piezoelectricity? Rutherford and Langevin on submarine detection and the invention of sonar10.1098/rsnr.2011.0049 ↗
6. Natural accumulation of Schottky-Frenkel defects: Implications for a quartz geochronometer10.1130/0091-7613(1988)017<0055:NAOSFD>2.3.CO;2 ↗
7. Bottom, V.E. (1981, January 27–29). A History of the quartz crystal industry in the USA. Proceedings of the 35th Annual Frequency Control Symposium, Abilene, TX, USA.10.1109/FREQ.1981.200452 ↗
8. The Evolution of the Quartz Crystal Clock10.1002/j.1538-7305.1948.tb01343.x ↗
9. Kinsman, R.G. (1998, January 27). A History of crystal filters. Proceedings of the 1998 IEEE International Frequency Control Symposium (Cat. No. 98CH36165), Pasadena, CA, USA.
10. Next Generation AT-Cut Quartz Crystal Sensing Devices10.3390/s110504474 ↗
11. The acceleration sensitivity of quartz crystal oscillators: A review10.1109/58.20450 ↗
12. Drive level dependency in quartz resonators10.1016/j.ijsolstr.2008.12.021 ↗
13. Use of quartz crystals for weighing thin layers and for microweighing10.1007/BF01337937 ↗
14. Determination of micromolar concentrations of cyanide in solution with a piezoelectric detector10.1016/S0003-2670(01)93171-X ↗
15. The oscillation frequency of a quartz resonator in contact with a liquid10.1016/S0003-2670(00)82721-X ↗
16. Development of circuit for measuring both Q variation and resonant frequency shift of quartz crystal microbalance10.1109/58.330261 ↗
17. New Quartz Oscillator Switching Method for Nano-Henry Range Inductance Measurements10.3390/s120303105 ↗
18. Alassi, A., Benammar, M., and Brett, D. (2017). Quartz Crystal Microbalance Electronic Interfacing Systems: A Review. Sensors, 17.10.3390/s17122799 ↗
19. Quartz-crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid environments10.1063/1.1145396 ↗
20. A simple setup to simultaneously measure the resonant frequency and the absolute dissipation factor of a quartz crystal microbalance10.1063/1.1147494 ↗
21. Johannsmann, D. (2007). Studies of viscoelasticity with the QCM. Piezoelectric Sensors, Springer.10.1007/5346_024 ↗
22. Burda, I. (2022). A Study on Regenerative Quartz Crystal Microbalance. Chemosensors, 10.10.3390/chemosensors10070262 ↗
23. Stéphane, M. (2009). Chapter 3—Discrete revolution. A Wavelet Tour of Signal Processing, Academic Press. [3rd ed.].10.1016/B978-0-12-374370-1.00007-0 ↗
24. Song, C., Ma, Z., Li, C., Zhang, H., Zhu, Z., and Wang, J. (2022). Application of Heat-Enhancement for Improving the Sensitivity of Quartz Crystal Microbalance. Biosensors, 12.10.3390/bios12080643 ↗
25. Evaporation of Sessile Drops: Application of the Quartz Crystal Microbalance10.1021/la990660l ↗
26. Improved frequency/voltage converters for fast quartz crystal microbalance applications10.1063/1.2908430 ↗
27. Quartz crystal microbalance based on passive frequency to voltage converter10.1063/1.3683234 ↗
28. On a Null Method of Testing Vibration Galvanometers10.1088/1478-7814/26/1/328 ↗
29. The Piezo-Electric Resonator and Its Equivalent Network
30. Network analysis based interface electronics for quartz crystal microbalance10.1063/1.1370560 ↗
31. Burda, I. (2022). Quartz Crystal Microbalance with Impedance Analysis Based on Virtual Instruments: Experimental Study. Sensors, 22.10.3390/s22041506 ↗
32. A Multiplexed Impedance Analyzer for Characterizing Polymer-Coated QCM Sensor Arrays10.1109/JSEN.2006.877936 ↗
33. Impedence analysis and circuit simulation of quartz resonator in water at different temperatures10.1016/S0925-4005(97)80024-X ↗
34. Burda, I. (2022). Advanced Impedance Spectroscopy for QCM Sensor in Liquid Medium. Sensors, 22.10.3390/s22062337 ↗
35. Horton, W.H., and Hague, G.E. (2005, January 29–31). Amplitude-frequency effects in VHF quartz resonators. Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, Vancouver, BC, Canada.
36. A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications10.1109/JSEN.2020.3042653 ↗
37. Bioinspired Sensor Systems10.3390/s111110180 ↗
38. Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading10.1021/ac00020a015 ↗
39. Electrochemical quartz crystal microbalance study of the transient response of passive Fe-25Cr alloy10.1016/S0013-4686(99)00293-5 ↗
40. (2022, May 24). Analod Discovery 2 Reference Manual. Available online: https://digilent.com/reference/test-and-measurement/analog-discovery-2/reference-manual.
41. Ojarand, J., Min, M., and Koel, A. (2019). Multichannel Electrical Impedance Spectroscopy Analyzer with Microfluidic Sensors. Sensors, 19.10.3390/s19081891 ↗
42. Kasper, M., Traxler, L., Salopek, J., Grabmayr, H., Ebner, A., and Kienberger, F. (2016). Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies. Biosensors, 6.10.3390/bios6020023 ↗
43. Development of a portable electrical impedance tomography system for biomedical applications10.1109/JSEN.2018.2864539 ↗
44. Statistics of atomic frequency standards10.1109/PROC.1966.4634 ↗
45. (2022, May 24). TimeLab. Available online: https://www.miles.io/timelab/beta.htm.
46. Transient Quartz Crystal Microbalance Behaviors Compared10.1149/1.1427080 ↗
47. Brendel, R., Addouche, M., Salzenstein, P., Rubiola, E., and Shmaliy, Y.S. (2004, January 5–7). Drive level dependence in quartz crystal resonators at low drive levels: A review. Proceedings of the 18th European Frequency and Time Forum (EFTF 2004), Guilford, UK.10.1049/cp:20040809 ↗
48. Bioinspired in-sensor visual adaptation for accurate perception10.1038/s41928-022-00713-1 ↗
49. Relation between superficial capillaries and foveal structures in the human retina