journal article·2026-04-09Open access

Can Non-Translational Simplified Tasks Mimic Knee Kinematics During Gait? A Comparative Study of Tibiofemoral ICR Trajectories

Fernando Valencia, Fernando Nadal, María Prado-Novoa

Biomimetics· Volume 11· Issue 4

Abstract

Understanding knee kinematics during gait is essential for the design of prostheses, orthoses, and biomimetic mechanisms. In many biomechanical analyses, tibiofemoral motion is simplified to the sagittal plane, allowing the locus of the instantaneous center of rotation (ICR) to describe joint kinematics derived from the instantaneous axis of rotation (IAR). However, it remains unclear whether ICR trajectories obtained from simplified flexion–extension tasks can represent those observed during gait. This study analyzes the sagittal-plane trajectory of the tibiofemoral ICR during gait swing, standing swing, seated swing, and squat. Motion data from 21 healthy participants were captured using videogrammetry, and the instantaneous axis of rotation (IAR) was computed from homogeneous transformation matrices using the Mozzi–Chasles theorem. Sagittal-plane ICR trajectories were derived and compared within subjects across tasks. Significant differences were found between gait and all other movements in both trajectory shape and spatial position. The shape metric (S), which quantifies differences in trajectory geometry, showed mean values ranging from 0.82 to 1.04 with very large effect sizes (Cohen’s d = 2.90 to 4.47, p < 0.0001). The centroid distance metric (M), which measures the overall spatial displacement between trajectories, indicated positional differences ranging from 8.15 mm to 12.37 mm between trajectories also showing very large effect sizes (Cohen’s = 1.72–3.40, p < 0.0001). Additionally, the mean deviation of the IAR from the sagittal plane ranged from 14° to 18° during gait, whereas smaller deviations were observed in non–weight-bearing swing movements. These results demonstrate that tibiofemoral ICR trajectories are task-dependent and that simplified flexion–extension tasks do not fully reproduce the knee kinematics observed during gait. Consequently, the use of gait-derived ICR trajectories, together with their variability, provides a more suitable basis for the design and optimization of polycentric mechanisms, enabling the development of devices that more closely replicate real biomechanics and are potentially better adapted to the user.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Total Knee Arthroplasty Outcomes · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Clinical Biomechanics Laboratory of Andalucia (BIOCLINA), University of Málaga, 29071 Malaga, Spain

Department of Mechatronics, Engineering, Faculty of Engineering in Applied Sciences, Universidad Técnica del Norte, Ibarra 100150, Ecuador

References (35)

Show source-provided references
1. A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee10.1115/1.3138397 ↗
2. The Flexion-Extension Response of a Novel Lumbar Intervertebral Disc Prosthesis: A Finite Element Study10.1016/j.mechmachtheory.2013.11.013 ↗
3. A Systematic Review on Design Technology and Application of Polycentric Prosthetic Knee in Amputee Rehabilitation10.1007/s13246-020-00882-3 ↗
4. Development and Characterisation of a Controllable Adjustable Knee Joint Mechanism10.1016/j.mechmachtheory.2020.104101 ↗
5. Zhang, Y., Wang, E., Wang, M., Liu, S., and Ge, W. (2021). Biomimetics Design and Experimental Research of Knee l Joint Prosthesis Based on Gait Acquisition Technology. Biomimetics, 6.10.3390/biomimetics6020028 ↗
6. Ayala, C., Valencia, F., Gámez, B., Salazar, H., and Ojeda, D. (2025). Personalized External Knee Prosthesis Design Using Instantaneous Center of Rotation for Improved Gait Emulation. Prosthesis, 7.10.20944/preprints202507.2301.v1 ↗
7. Valencia, F., Gámez, B., Ojeda, D., and Salazar, H. (2026). Mechatronic Device for Accurate Characterization of Knee Flexion Based on Pivot Point. Biomechanics, 6.10.3390/biomechanics6010008 ↗
8. Tibio-Femoral Kinematics of the Healthy Knee Joint throughout Complete Cycles of Gait Activities10.1016/j.jbiomech.2020.109915 ↗
9. Assessment of Knee Kinematics in Older Adults Using High-Speed Stereo Radiography10.1249/MSS.0000000000001350 ↗
10. In Vivo Fluoroscopic Analysis of the Normal Human Knee10.1097/01.blo.0000062384.79828.3b ↗
11. Beauchet, O., Allali, G., Sekhon, H., Verghese, J., Guilain, S., Steinmetz, J.P., Kressig, R.W., Barden, J.M., Szturm, T., and Launay, C.P. (2017). Guidelines for Assessment of Gait and Reference Values for Spatiotemporal Gait Parameters in Older Adults: The Biomathics and Canadian Gait Consortiums Initiative. Front. Hum. Neurosci., 11.10.3389/fnhum.2017.00353 ↗
12. Knee Kinematics of Healthy Adults Measured Using Biplane Radiography10.1115/1.4047419 ↗
13. Kinematics and Center of Axial Rotation during Walking after Medial Pivot Type Total Knee Arthroplasty10.1186/s40634-020-00286-y ↗
14. Insufficient Lateral Joint Laxity after Bicruciate-Retaining Total Knee Arthroplasty Potentially Influences Kinematics during Flexion: A Biomechanical Cadaveric Study10.1016/j.knee.2020.12.008 ↗
15. Koçak, M., and Gezgin, E. (2025). Unified Design Methodology for a Polycentric Transfemoral Knee Prosthesis Using Kinematic Synthesis. Machines, 13.10.3390/machines13010020 ↗
16. Chávez, F., Cabrera, J.A., Bataller, A., and Pérez, J. (2025). Design and Validation of a Walking Exoskeleton for Gait Rehabilitation Using a Dual Eight-Bar Mechanism. Technologies, 13.10.3390/technologies13100463 ↗
17. Three-Dimensional Motion of the Knee-Joint Complex during Normal Walking Revealed by Mobile Biplane x-Ray Imaging10.1002/jor.24226 ↗
18. Human Movement Analysis Using Stereophotogrammetry. Part 1: Theoretical Background
19. Quantification of Soft Tissue Artifact in Lower Limb Human Motion Analysis: A Systematic Review10.1016/j.gaitpost.2009.09.004 ↗
20. In Vivo Knee Kinematics during Gait Reveals New Rotation Profiles and Smaller Translations10.1097/BLO.0b013e31802dc4d0 ↗
21. Three-dimensional kinematics of the human knee during walking10.1016/0021-9290(92)90254-X ↗
22. Methodological Concerns Using Intra-Cortical Pins to Measure Tibiofemoral Kinematics10.1007/s00167-003-0388-1 ↗
23. Kefala, V., Ali, A.A., Hamilton, L.D., Mannen, E.M., and Shelburne, K.B. (2022). Effects of Weight-Bearing on Tibiofemoral, Patellofemoral, and Patellar Tendon Kinematics in Older Adults. Front. Bioeng. Biotechnol., 10.10.3389/fbioe.2022.820196 ↗
24. Differences in the Flexion and Extension Phases during Kneeling Investigated by Kinematic and Contact Point Analyses: A Cross-Sectional Study10.1186/s13018-022-03080-x ↗
25. Dynamic Activity Dependence of in Vivo Normal Knee Kinematics10.1002/jor.20488 ↗
26. In Vivo Healthy Knee Kinematics during Dynamic Full Flexion10.1155/2013/717546 ↗
27. In Vivo Three-Dimensional Kinematics of Normal Knees during Different High-Flexion Activities10.1302/0301-620X.100B1.BJJ-2017-0553.R2 ↗
28. External Knee Joint Design on Normal Motion10.1682/JRRD.1985.01.0009 ↗
29. Biomechanical Analysis of the Knee after Rupture of the Anterior Cruciate Ligament and Its Primary Repair. An Instant-Centre Analysis of Function10.1302/0301-620X.65B4.6874709 ↗
30. Methods, Difficulties and Inaccuracies in the Study of Human Joint Kinematics and Pathokinematics by the Instant Axis Concept. Example: The Knee Joint10.1016/0021-9290(79)90006-X ↗
31. Gasparutto, X., Bonnefoy-Mazure, A., Attias, M., Turcot, K., Armand, S., and Miozzari, H.H. (2024). Comprehensive Analysis of Total Knee Arthroplasty Kinematics and Functional Recovery: Exploring Full-Body Gait Deviations in Patients with Knee Osteoarthritis. PLoS ONE, 19.10.1371/journal.pone.0314991 ↗
32. New Fluoroscopic Imaging Technique for Investigation of 6DOF Knee Kinematics during Treadmill Gait10.1186/1749-799X-4-6 ↗
33. Tibiofemoral Kinematics and Condylar Motion during the Stance Phase of Gait10.1016/j.jbiomech.2009.05.003 ↗
34. A Soft Tissue Artefact Model Driven by Proximal and Distal Joint Kinematics10.1016/j.jbiomech.2014.04.029 ↗
35. Lin, C.C., Lu, H.L., Lu, T.W., Wang, C.Y., Li, J.D., Kuo, M.Y., and Hsu, H.C. (2021). Reconstruction of Three-Dimensional Tibiofemoral Kinematics Using Single-Plane Fluoroscopy and a Personalized Kinematic Model. Appl. Sci., 11.10.3390/app11209415 ↗