journal article·2021-05-31Open access

Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips

Takehito Hananouchi, Soshi Uchida, Yusuke Hashimoto, Funakoshi Noboru, Stephen K. Aoki

Biomimetics· Volume 6· Issue 2

Abstract

Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hip disorders and treatments · Orthopaedic implants and arthroplasty · Shoulder Injury and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Medical Engineering Laboratory, Department of Mechanical Engineering, Faculty of Engineering, Osaka Sangyo University, Daito, Osaka 574-8530, Japan

Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan

Department of Orthopaedic Surgery, Wakamatsu Hospital of University of Occupational and Environmental Health, Kitakyushu 808-0024, Japan

Department of Orthopaedic Surgery, Graduate School of Medicine, Osaka City University, Abeno-ku, Osaka 545-8585, Japan

Department of Orthopaedic Surgery, Kyoto Shimogamo Hospital, Kyoto 606-0866, Japan

Department of Orthopaedics, University of Utah, Salt Lake City, UT 84108, USA

Funding

Japan Society for the Promotion of Science

References (12)

Show source-provided references
1. Marin-Peña, O., Lund, B., Ayeni, O.R., Dantas, P., Griffin, D., Khanduja, V., Said, H.G., Tey, M., Dickenson, E., and Kay, J. (2017). Basic Concepts in Hip Arthroscopy. ESSKA Instructional Course Lecture Book, J.B. Metzler.10.1007/978-3-662-56127-0_4 ↗
2. Surgical Indications for Arthroscopic Management of Femoroacetabular Impingement10.1016/j.arthro.2012.01.010 ↗
3. Transferring simulated arthroscopic skills to the operating theatre10.1302/0301-620X.90B4.20414 ↗
4. Systematic review of the current status of cadaveric simulation for surgical training10.1002/bjs.11325 ↗
5. Quantitative evaluation of capsular and labral resistances in the hip joint using a probing device10.3233/BME-191056 ↗
6. Hananouchi, T. (2020). A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy. J. Vis. Exp., e60722.10.3791/60722-v ↗
7. Arthroscopic Double Shoelace Capsular Plication Technique for the Treatment of Borderline Hip Dysplasia Associated with Capsular Laxity10.1016/j.eats.2019.04.008 ↗
8. Proposed Referential Index to Resect Femoroacetabular Cam-Type Impingement During Arthroscopy Using a Cadaveric Hip Model10.1016/j.arthro.2014.12.024 ↗
9. Hip Arthroscopy and the Anterolateral Portal: Avoiding Labral Penetration and Femoral Articular Injuries10.1016/j.eats.2012.05.007 ↗
10. Probing forces of menisci: What levels are safe for arthroscopic surgery10.1007/s00167-010-1251-9 ↗
11. Smart tool for force measurements during knee arthroscopy: In vivo human study
12. Hananouchi, T., Chen, Y., Jerban, S., Teramoto, M., Ma, Y., Dorthe, E., Chang, E., Du, J., and D’Lima, D. (2021). A Useful Combination of Quantitative Ultrashort Echo Time MR Imaging and a Probing Device for Biomechanical Evaluation of Articular Cartilage. Biosensors, 11.10.3390/bios11020052 ↗