journal article·2026-05-01Open access

An Efficient Multi-Channel Electrotactile Parameter Configuration Method for Personalized Teleoperation

Kaicheng Zhang, Kairu Li, Peiyao Wang, Yixuan Sheng

Biomimetics· Volume 11· Issue 5

Abstract

Electrotactile feedback is a compact approach for providing tactile cues in robotic teleoperation, but personalized calibration remains time-consuming because tactile perception varies across users. To address this problem, this study develops a subject-informed multi-layer finite element model of fingertip electric-field distribution coupled with a neural-response model and proposes a simulation-derived configuration-ranking method termed the Perceived Correctness Score (PCS). A gradient boosting regression model is then used to recommend among 36 candidate electrode diameter–spacing combinations. Validation was conducted using a custom-developed 3 × 2 multi-channel fingertip electrotactile stimulation system in a shape/area recognition task involving six healthy subjects. The predicted PCS showed a moderate positive correlation with the measured mean recognition accuracy across configurations (Pearson r = 0.48, p < 0.05). The model achieved Top-1 exact matching for three of six subjects and Top-5 coverage for five of six subjects. Compared with conventional exhaustive psychophysical calibration, the proposed method reduced the average configuration time from 122.7 min to 16.0 min, corresponding to an efficiency improvement of 87.0%. These results show that model-guided ranking can substantially reduce the burden of individualized electrotactile configuration.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Tactile and Sensory Interactions · EEG and Brain-Computer Interfaces · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China

State Key Laboratory of Robotics and System, Harbin Institute of Technology Shenzhen, Shenzhen 150001, China

Funding

Shenyang Special Training Program for Young Scientific and Technological Innovation Talents · LiaoNing Revitalization Talents Program · Research Fund of Liaoning Provincial Department of Education · National Natural Science Foundation of China

References (39)

Show source-provided references
1. Effective capture of nongraspable objects for space robots using geometric cage pairs10.1109/TMECH.2019.2952552 ↗
2. Haptics-based robot teleoperation for soft object manipulation10.1061/JCEMD4.COENG-15819 ↗
3. Enhancing telecooperation through haptic twin for internet of robotic things: Implementation and challenges10.1109/JIOT.2024.3424936 ↗
4. Design and development of a dexterous bilateral robotic microinjection system based on haptic feedback10.1109/TASE.2022.3182409 ↗
5. Robust Localization Algorithm for Micromanipulation Targets Under Complex Interference Conditions10.1109/TASE.2025.3631003 ↗
6. Coordinated Tracking Control of the Integrated Wheel-End System Based on Generalized Instantaneous Steering Center Constraint10.1109/TTE.2025.3538892 ↗
7. Constraint Control of Electro-Hydraulic Position Servo System Based on Command Filter
8. Robust Control Under Servo Constraint Following via Nash Equilibrium Theory for Bimanual Humanoid Manipulation10.1109/TFUZZ.2025.3609828 ↗
9. A Segmented Activation Function-Based Zeroing Neural Network Model for Dynamic Sylvester Equation Solving and Robotic Manipulator Control10.1002/cpe.70243 ↗
10. Haptic feedback and force-based teleoperation in surgical robotics10.1109/JPROC.2022.3180052 ↗
11. Cutaneous/tactile haptic feedback in robotic teleoperation: Motivation, survey, and perspectives10.1109/TRO.2023.3344027 ↗
12. Yang, S., Wang, X., Li, Y., Lee, L.H., Braud, T.C., and Hui, P. (2025). A Comprehensive Survey of Electrical Stimulation Haptic Feedback in Human-Computer Interaction. arXiv.
13. Seminara, L., Strbac, M., Amin, Y., Valle, M., and Dosen, S. (2022). Artificial Skin and Electrotactile Stimulation for Advanced Tactile Feedback in Myoelectric Prostheses. Electronic Skin, River Publishers.10.1201/9781003338062-9 ↗
14. Wearable haptic systems for the fingertip and the hand: Taxonomy, review, and perspectives10.1109/TOH.2017.2689006 ↗
15. Neural basis of touch and proprioception in primate cortex10.1002/j.2040-4603.2018.tb00045.x ↗
16. Towards safe motion planning for industrial human–robot interaction: A co-evolution approach based on human digital twin and mixed reality10.1016/j.rcim.2025.103012 ↗
17. Robust Human Interaction Recognition Using Extended Kalman Filter
18. Multi-sensor fusion-based intelligent auxiliary system of power wheelchairs for individuals with limbs disabilities: Design and implementation10.1016/j.measurement.2025.118573 ↗
19. Smooth Path Planning and Dynamic Contact Force Regulation for Robotic Ultrasound Scanning10.1109/LRA.2025.3604746 ↗
20. Neuroergonomics evaluation of teamwork in a fast-paced communication and shared decision-making task10.1016/j.ergon.2026.103892 ↗
21. Novel electrode designs for electrotactile stimulation of the finger: A comparative assessment10.1109/TOH.2023.3321925 ↗
22. Two-point tactile discrimination ability is influenced by temporal features of stimulation10.1007/s00221-014-3908-y ↗
23. The impact of size and position of reference electrode on the localization of biphasic electrotactile stimulation on the fingertips10.1109/TOH.2022.3141187 ↗
24. Multichannel electrotactile feedback with spatial and mixed coding for closed-loop control of grasping force in hand prostheses10.1109/TNSRE.2016.2550864 ↗
25. Dual-parameter modulation improves stimulus localization in multichannel electrotactile stimulation10.1109/TOH.2019.2950625 ↗
26. Age, gender, and side differences of cutaneous electrical perceptual threshold testing in an able-bodied population10.1080/10790268.2010.11689702 ↗
27. Yem, V., Ikei, Y., and Kajimoto, H. (2024). Study of Cathodic Electrotactile Stimulus Current Estimation on Fingertip Using Individual Skin Impedance and Machine Learning. Proceedings of the International Conference on Human Haptic Sensing and Touch Enabled Computer Applications, Springer.10.1007/978-3-031-70061-3_3 ↗
28. Optimization of semiautomated calibration algorithm of multichannel electrotactile feedback for myoelectric hand prosthesis
29. Malešević, J., Kostić, M., Jure, F.A., Spaich, E.G., Došen, S., Ilić, V., Bijelić, G., and Štrbac, M. (2022). Electrotactile Communication via Matrix Electrode Placed on the Torso Using Fast Calibration, and Static vs. Dynamic Encoding. Sensors, 22.10.3390/s22197658 ↗
30. Electrical conductivity of tissue at frequencies below 1 MHz10.1088/0031-9155/54/16/002 ↗
31. The dielectric properties of biological tissues: I. Literature survey10.1088/0031-9155/41/11/001 ↗
32. Validating a population model of tactile mechanotransduction of slowly adapting type I afferents at levels of skin mechanics, single-unit response and psychophysics10.1109/TOH.2013.36 ↗
33. Myelinated nerve endings in human skin10.1002/mus.20771 ↗
34. Zhu, K., Li, L., Wei, X., and Sui, X. (2017). A 3D Computational Model of Transcutaneous Electrical Nerve Stimulation for Estimating Aβ Tactile Nerve Fiber Excitability. Front. Neurosci., 11.10.3389/fnins.2017.00250 ↗
35. Finite element analysis of electric field distribution during direct current stimulation of the spinal cord: Implications for device design10.1063/5.0163264 ↗
36. Highly efficient modeling and optimization of neural fiber responses to electrical stimulation10.1038/s41467-024-51709-8 ↗
37. Sensory effects of transient electrical stimulation-evaluation with a neuroelectric model10.1109/TBME.1985.325509 ↗
38. Greedy function approximation: A gradient boosting machine10.1214/aos/1013203451 ↗
39. Modeling the excitation of nerve axons under transcutaneous stimulation10.1016/j.compbiomed.2023.107463 ↗