Iron-on carbon nanotube (CNT) thin films for biosensing E-Textile applications
Source abstract
Abstract
Abstract Conductive carbon nanotube-thermoplastic polyurethane (CNT-TPU) composite thin films are patterned and integrated onto knitted textile substrates to form electronic textile (E-Textile) dry electrodes. Vertically aligned CNT arrays are mechanically drawn into thin CNT sheets and infiltrated with a TPU solution to form the CNT-TPU thin films. The CNT-TPU thin films are then heat laminated onto knitted textile substrates to form dry E-Textile electrodes. To understand the wearability of our CNT-TPU thin films we perform an in-depth analysis of the films’ electromechanical properties, electrical impedance, and electrocardiogram (ECG) sensing performance. The electromechanical coupling between the CNT thin films and knitted textile substrates show a strong anisotropic dependence between the CNT film alignment and textile knit structure. Further analysis into the CNT thin films reveal that larger electrode sizes with a larger number of CNT sheet layers in the film, lead to more favorable impedance behaviors and ECG sensing capabilities. As a wearable demonstration, we fabricate a textile arm sleeve integrated with CNT thin film electrodes to form an ECG sensing E-Textile system. The proposed E-Textile sleeve demonstrates the practicality of our CNT thin films and show promise for other E-Textile and wearable applications.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Inkjet process for conductive patterning on textiles: maintaining inherent stretchability and breathability in knit structures
2. Inkjet printing of reactive silver ink on textiles10.1021/acsami.8b18231 ↗
3. Flexible technologies for self-powered wearable health and environmental sensing10.1109/JPROC.2015.2412493 ↗
4. Wearable silver nanowire dry electrodes for electrophysiological sensing10.1039/C4RA15101A ↗
5. Porous textile antenna designs for improved wearability10.1088/1361-665X/aaaf91 ↗
6. Soft bioelectronic stickers: selection and evaluation of skin-interfacing electrodes10.1002/adhm.201900234 ↗
7. Dry electrodes for electrocardiography10.1088/0967-3334/34/9/R47 ↗
8. Low-dimensional carbon based sensors and sensing network for wearable health and environmental monitoring10.1016/j.carbon.2017.06.006 ↗
9. Flexible carbon nanotube-based polymer electrode for long-term electrocardiographic recording
10. Self-adhesive epidermal carbon nanotube electronics for tether-free long-term continuous recording of biosignals
11. PU nanoweb-based textile electrode treated with single-walled carbon nanotube/silver nanowire and its application to ECG monitoring10.1088/1361-665X/ab06e0 ↗
12. Simple and cost-effective method of highly conductive and elastic carbon nanotube/polydimethylsiloxane composite for wearable electronics
13. A highly durable, stretchable, transparent and conductive carbon nanotube-polymeric acid hybrid film10.1039/C8NR08399A ↗
14. Dispersion and functionalization of carbon nanotubes for polymer-based nanocomposites: a review10.1016/j.compositesa.2010.07.003 ↗
15. Bioinspired fluffy fabric with in situ grown carbon nanotubes for ultrasensitive wearable airflow sensor10.1002/adma.201908214 ↗
16. Integrated textile sensor patch for real-time and multiplex sweat analysis10.1126/sciadv.aax0649 ↗
17. Highly stretchable, and conductive dry adhesives based on 1D-2D hybrid carbon nanocomposites for all-in-one ECG electrodes10.1021/acsnano.6b01355 ↗
18. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring10.1109/TBME.2012.2190288 ↗
19. Conformal atomic layer deposition of alumina on millimeter tall, vertically-aligned carbon nanotube arrays10.1021/am505107s ↗
20. Aligned carbon nanotube-silicon sheets: a novel nano-architecture for flexible lithium ion battery electrodes10.1002/adma.201301920 ↗
21. A novel approach to fabricate high volume fraction nanocomposites with long aligned carbon nanotubes10.1016/j.compscitech.2010.07.020 ↗
22. Aligned carbon nanotube sheet high efficiency particulate air filters10.1016/j.carbon.2013.07.066 ↗
23. High performance carbon nanotube-polymer nanofiber hybrid fabrics10.1039/C5NR02732B ↗
24. Hybrid carbon nanotube fabrics with sacrificial nanofibers for flexible high performance lithium-ion battery anodes10.1149/2.0821902jes ↗
25. Beck · U.S. Patent Application · 1989 · 4 · 913
26. Thermoplastic polyurethane technologies for the textile industry
27. A review on coating & lamination in textiles: processes and applications10.5923/j.ajps.20120203.04 ↗
28. Printed stretchable interconnects for smart garments: design, fabrication and characterization10.1109/JSEN.2016.2605071 ↗
29. Properties and applications of vapor infiltration into polymeric substrates10.1007/s11837-018-3157-9 ↗
30. Woven electronic fibers with sensing and display functions for smart textiles10.1002/adma.201002159 ↗
31. In-plane deformation mechanics for highly stretchable electronics10.1002/adma.201604989 ↗
32. Kirigami-inspired textile electronics: K.I.T.E10.1002/admt.201900511 ↗
33. Evaluating major electrode types for idle biological signal measurements for modern medical technology10.3390/bioengineering3030020 ↗
34. Fabric-based wearable dry electrodes for body surface biopotential recording10.1109/TBME.2015.2462312 ↗
35. Efficient skin temperature sensor and stable gel-less sticky ECG sensor for a wearable flexible healthcare patch10.1002/adhm.201700495 ↗
36. A wearable health care system based on knitted integrated sensors10.1109/TITB.2005.854512 ↗
37. Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel
38. Fundamentals of electrocardiography interpretation10.2344/0003-3006(2006)53[53:FOEI]2.0.CO;2 ↗
39. Screen-printed PEDOT:PSS electrodes on commercial finished textiles for electrocardiography10.1021/acsami.7b09954 ↗
40. Impact of skin-electrode interface on electrocardiogram measurements using conductive textile electrodes10.1109/TIM.2013.2289072 ↗
41. Sensitivity analysis of wearable textiles for ECG sensing
42. A hybrid textile electrode for electrocardiogram (ECG) measurement and motion tracking10.3390/ma11101887 ↗
43. A proof-of-concept study: simple and effective detection of P and T waves in arrhythmic ECG signals10.3390/bioengineering3040026 ↗
44. From Holter monitors to automatic defibrillators: developments in ambulatory arrhythmia monitoring10.1109/TBME.1984.325237 ↗
45. Advanced carbon for flexible and wearable electronics10.1002/adma.201801072 ↗
46. Advances in carbon nanotube n-type doping: methods, analysis and applications10.1016/j.carbon.2017.09.107 ↗