During walking, the foot is in direct contact with the insole of the footwear, and it affects the biomechanics of the whole human body. The aim of this study was to compare the plantar pressure distribution while walking in the same footwear in three different situations: with an original footwear insole, with an ethylene-vinyl acetate customized insole, and with a 3D printed anatomical insole to find out the optimal insoles for people with a normal, flat, and high arched foot according to the plantar pressure relief. Fifty-one adults were grouped into three groups (normal foot, flat foot, and high arched foot geometry). The feet of the randomly selected subjects from each group were scanned, and the insoles were designed on the basis of the foot model. These models were then used for the 3D printing. The plantar pressure distribution was observed when walking in all three different insole types for each of the three subjects with the different foot types. The peak pressure values in the forefoot, midfoot, and rearfoot and contact area were compared. The results of the study show that customized insoles influence the plantar pressure distribution mainly in people with a flat foot or with a high arched foot deformity. This influence is dependent on the type of the customized insoles, mainly in people with a high arched foot. People with a flat foot deformity have a similar plantar pressure relief in the thermoplastic insoles as those in the 3D printed insoles, and both these customized insoles can be used as a supplementary therapeutic instrument. Our study showed that the biggest attention, with regards to customizing insoles, is required by people with a high arched foot deformity, and we recommend that these people use fully customized insoles which can be guaranteed with 3D printing techniques.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Diabetic Foot Ulcer Assessment and Management · Lower Extremity Biomechanics and Pathologies · Foot and Ankle Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Applied Mechanics, Faculty of Mechanical Engineering, Technical University of Liberec, Liberec, Czech Republic.

Department of Physical Education, Faculty of Education, Charles University, Prague, Czech Republic.

Department of Manufacturing Systems and Automation, Faculty of Mechanical Engineering, Technical University of Liberec, Liberec, Czech Republic.

References (29)

Show source-provided references
1. 10.1016/j.gaitpost.2015.03.00410.1016/j.gaitpost.2015.03.004 ↗
2. Jandova S, , Fronkova M, , Novakova K. Influence of instable construction shoes on usual gait cycle at walk on treadmill with 10° ascent. Rehabilitacia, 2013; 50:226–231.
3. 10.1016/j.clinbiomech.2005.08.00310.1016/j.clinbiomech.2005.08.003 ↗
4. Jandova S, , Volf P, , Vaverka F. The Influence of minimalist and conventional sports shoes and lower limbs dominance on running gait. Acta Bioeng Biomech, 2018; 20:3–9.
5. 10.1016/j.jsams.2014.06.00710.1016/j.jsams.2014.06.007 ↗
6. 10.23736/S0025-7826.18.03029-610.23736/S0025-7826.18.03029-6 ↗
7. 10.1016/j.compind.2017.12.00110.1016/j.compind.2017.12.001 ↗
8. 10.1016/j.joca.2013.02.35610.1016/j.joca.2013.02.356 ↗
9. 10.1016/S1067-2516(97)80071-310.1016/S1067-2516(97)80071-3 ↗
10. 10.1016/j.clinbiomech.2004.02.01010.1016/j.clinbiomech.2004.02.010 ↗
11. 10.2337/dc07-228810.2337/dc07-2288 ↗
12. 10.3113/FAI.2007.001510.3113/FAI.2007.0015 ↗
13. 10.1016/j.jbiomech.2014.12.04310.1016/j.jbiomech.2014.12.043 ↗
14. 10.2337/dc10-220610.2337/dc10-2206 ↗
15. Kapandji IA. The Physiology of Joints. Lower Limb. London: Churchill Livingstone 1987.
16. 10.3113/FAI.2007.045610.3113/FAI.2007.0456 ↗
17. 10.5194/isprs-archives-XL-5-W8-7-201610.5194/isprs-archives-XL-5-W8-7-2016 ↗
18. 10.17973/MMSJ.2016_12_201618310.17973/MMSJ.2016_12_2016183 ↗
19. Wei X, , Thakare K, , Zeng L, et al. Experimental investigation of Stratasys J750 PolyJet Printer: Effects of finish type and shore hardness on dimensional accuracy. In: Proceedings of the ASME 2019 14th International Manufacturing Science and Engineering Conference. Erie, PA, 2019.
20. 10.17973/MMSJ.2017_12_20177610.17973/MMSJ.2017_12_201776 ↗
21. Mendricky R. Accuracy analysis of additive technique for parts manufacturing. MM Sci J, 2019; 5:1502–1508.
22. Stratasys. Stratasys Support Center—Objet Connex 350/500. Retrieved June 4 2021. Available at: https://support.stratasys.com/en/printers/polyjet-legacy/connex350-500 (last accessed July26 2021).
23. 10.1016/j.proeng.2015.12.48110.1016/j.proeng.2015.12.481 ↗
24. 10.3944/AOTT.2012.240110.3944/AOTT.2012.2401 ↗
25. Jandova S. Plantar pressure distribution during walking after specific soft tissue heel injury—case study. In: Experimental Stress Analysis—56th International Scientific Conference EAN 2018—Conference Proceedings. Liberec: Czech Society for Mechanics 2018;pp. 144–149.
26. 10.1016/j.gaitpost.2013.10.01810.1016/j.gaitpost.2013.10.018 ↗
27. Trelevaen P. Sizing s up—new 3D body scanners are reshaping cloathing car seats and more. IEEE Spectr, 2004; 41:17–19.
28. 10.1097/01.PHM.0000087455.38062.7910.1097/01.PHM.0000087455.38062.79 ↗
29. Payne C. Cost benefit comparison of plaster casts and optical scans of the foot for the manufacture of foot orthoses. Australasian J Podiat Med, 2007; 41:29–31.