This study investigated magnetic deflection shielding for the beta-particle/electron component emitted from Cs-137 using PHITS Monte Carlo simulations. A 1 Ci Cs-137 planar source was modeled in air, and deposited dose rates were evaluated for effective magnetic-field lengths of 1.0, 2.0, and 3.0 cm over magnetic flux densities of 0.0–1.3 T. Photon transport was included in the coupled electron–photon calculation, but deposited dose scoring was restricted to the beta-particle/electron component. At the 30 cm source-to-scoring distance, the 1.0-cm condition showed a minimum dose rate at 0.8 T, followed by dose rebound at higher magnetic flux densities. A similar non-monotonic trend was observed in the additional 15 cm simulation. In contrast, the 2.0- and 3.0-cm conditions reached practical saturation at approximately 0.4 and 0.3 T, respectively. These results demonstrate that compact magnetic deflection shielding should be optimized using the field–length combination rather than magnetic flux density alone, and that effective lengths of 2–3 cm provide a more stable design range for mobile charged-particle shielding devices.