High-resolution imaging of cylindrical cells using curved-scintillator-based optically coupled X-ray computed tomography
Source abstract
Abstract
X-ray computed tomography (CT) is widely used for nondestructive inspection of cylindrical lithium-ion batteries. However, in conventional flat-detector-based CT systems, spatial resolution is limited by focal-spot-induced blurring, which becomes severe at the cell periphery due to an increased object-to-detector distance. This is particularly problematic for cylindrical battery inspection, where resolving peripheral features such as electrode termination positions is essential. Here, we present a curved-scintillator-based optically coupled X-ray CT system that reduces the effective object-to-detector distance at the periphery, suppressing focal-spot-induced blurring while enabling the use of a high-power X-ray tube. The system is experimentally demonstrated through CT imaging of a 4680 cylindrical lithium-ion cell. The curved scintillator improves peripheral spatial resolution by approximately 8% compared with the flat-scintillator configuration, providing more uniform resolution across the field of view. Frequency- and image-domain resolution analyses confirm the improvement, indicating the potential of the curved-scintillator-based system for high-resolution inspection of cylindrical lithium-ion batteries.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Particle Detector Development and Performance · Advancements in Battery Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. X-ray tomography for lithium-ion battery research: A practical guide10.1146/annurev-matsci-070616-123957 ↗
2. Multi-level X-ray computed tomography (XCT) investigations of commercial lithium-ion batteries from cell to particle level10.1016/j.est.2023.107453 ↗
3. Assessing rechargeable batteries with 3D X-ray microscopy, computed tomography, and nanotomography10.1080/10589759.2022.2070165 ↗
4. X-ray tomography for lithium ion battery electrode characterisation — A review10.1016/j.egyr.2021.02.063 ↗
5. Effect of geometric magnification on dimensional measurements with a metrology-grade X-ray computed tomography system10.1016/j.precisioneng.2021.10.015 ↗
6. Carmignato · 2017
7. X-Ray Imaging Physics for Nuclear Medicine Technologists. Part 1: Basic Principles of X-Ray Production
8. Quantitative X-ray tomography10.1179/1743280413Y.0000000023 ↗
9. Artifacts in CT: Recognition and avoidance10.1148/rg.246045065 ↗
10. Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis, Med
11. In-operando high-speed tomography of lithium-ion batteries during thermal runaway10.1038/ncomms7924 ↗
12. 4D imaging of lithium-batteries using correlative neutron and X-ray tomography with a virtual unrolling technique10.1038/s41467-019-13943-3 ↗
13. Optically-Coupled X-Ray Computed Laminography System for High-Speed Inspection of Lithium-Ion Batteries10.1002/advs.202517158 ↗
14. Improving small animal cone beam CT resolution by mitigating x-ray focal spot induced blurring via deconvolution10.1088/1361-6560/ac6b7a ↗
15. Curved digital X-ray detectors10.1038/s41528-020-00084-7 ↗
16. Lead-Free Ga2O3–TeO2Glass for Sustainable X-ray Detection and 3D Curved Imaging10.1021/acsami.5c16886 ↗
17. Curving monolithic silicon for nonplanar focal plane array applications
18. Curved focal plane detector array for wide field cameras10.1364/AO.51.005419 ↗
19. Highly curved image sensors: a practical approach for improved optical performance10.1364/OE.25.013010 ↗
20. In-situ grown polymer-ceramic scintillator and applications on X-ray multi-energy curved surface imaging10.1186/s43074-025-00179-2 ↗
21. Microfocus X-ray tubes with increased power10.1088/1742-6596/872/1/012002 ↗
22. Heat management of a compact x-ray source for microbeam radiotherapy and FLASH treatments10.1002/mp.15611 ↗
23. Synchrotron radiation X-ray imaging with large field of view and high resolution using micro-scanning method10.1107/S1600577522007652 ↗
24. Lithium Plating at the Cell Edge Induced by Anode Overhang during Cycling in Lithium-Ion Batteries: Part I. Modeling and Mechanism10.1149/1945-7111/ad4a12 ↗
25. Quantifying the local resolution of cryo-EM density maps10.1038/nmeth.2727 ↗
26. Performance of a CsI(Tl) scintillation screen with a dual-periodic structure based on an oxidized silicon micropore array template in X-ray imaging10.1364/OE.428145 ↗
27. Refracting Röntgen’s rays: Propagation-based x-ray phase contrast for biomedical imaging10.1063/1.3115402 ↗
28. Equivalent intrinsic blur in spatial vision10.1016/0042-6989(90)90016-E ↗
29. Infrared micro-particle image velocimetry measurements and predictions of flow distribution in a microchannel heat sink10.1016/j.ijheatmasstransfer.2007.06.034 ↗
30. On the manufacture and theory of diffraction-gratings10.1080/14786447408641116 ↗
31. Fourier shell correlation threshold criteria10.1016/j.jsb.2005.05.009 ↗