Understanding ethanol versus methanol formation from insulating paper in power transformers
Source abstract
Abstract
Abstract The life of an electrical transformer is mainly determined by that of its cellulosic solid insulation. The analysis of the chemical markers of cellulose degradation dissolved in oil is a simple and economical way to indirectly characterize the insulating paper. Methanol, a marker that is intimately linked to the rupturing of 1,4-β-glycosidic bonds of cellulose, has been observed together with ethanol during laboratory ageing experiments. Regardless of the simulated ageing conditions (temperature, humidity, air), the ratio of methanol to ethanol concentration is always higher than one (unity). However, in approximately 10 % of transformer oil samples, the ethanol generation is higher than that of methanol. In this study, thermal degradation by pyrolysis is coupled with gas chromatography/mass spectrometry to assess the volatile by-products generated at high temperatures with emphasis on methanol/ethanol generation. Some cellulose model compounds were also pyrolyzed and thermally aged in oil. The results showed that the generation of ethanol from paper pyrolysis is always smaller than for methanol, but it only occurs at temperatures higher than 300 °C. However, thermal ageing of levoglucosan in oil generates a massive amount of ethanol compared to methanol regardless of the conditions (temperature, humidity, air, nitrogen, acidity). The hypothesis that ethanol is a by-product of cellulose degradation through levoglucosan as an intermediary in power transformers is proposed. The presence of ethanol during transformer oil analysis is of high interest because it can be related to a thermal fault or hot spot within the solid insulation.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Transformer Diagnostics and Insulation · Advanced Cellulose Research Studies · High voltage insulation and dielectric phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Bicchieri M, Bella M, Semetilli F (1999) A quantitative measure of borane tert-butylamine complex effectiveness in carbonyl reduction of aged papers. Restaurator 20:22–29. doi:10.1515/rest.1999.20.1.2210.1515/rest.1999.20.1.22 ↗
2. Blue R, Uttamchandani D, Farish O (1998) Infrared detection of transformer insulation degradation due to accelerated thermal aging. IEEE Trans Dielectr Electr Insul 5:165–168. doi:10.1109/94.67192410.1109/94.671924 ↗
3. Burton PJ, Graham J, Hall AC, Laver JA, Oliver AJ (1984) Recent developments by CEGB to improve the prediction and monitoring of transformer performance. Presented at the CIGRE conference, Paris, France, September 1984
4. Caballero JA, Font R, Marcilla A (1997) Pyrolysis of Kraft lignin: yields and correlations. J Anal Appl Pyrol 39:161–183. doi:10.1016/S0165-2370(96)00965-510.1016/S0165-2370(96)00965-5 ↗
5. CDS Analytical Inc. Operating Manual for Pyroprobe 1000, 2000, AS 2500
6. Degroot WF, Pan W-P, Rahman MD, Richards GN (1988) First chemical events in pyrolysis of wood. J Anal Appl Pyrol 13:221–231. doi:10.1016/0165-2370(88)80024-X10.1016/0165-2370(88)80024-X ↗
7. Diebold JP (1994) A unified, global model for the pyrolysis of cellulose. Biomass Bioenergy 7:75–85. doi:10.1016/0961-9534(94)00039-V10.1016/0961-9534(94)00039-V ↗
8. Emsley AM (1994) The kinetics and mechanisms of degradation of cellulosic insulation in power transformers. Polym Degrad Stab 44:343–349. doi:10.1016/0141-3910(94)90093-010.1016/0141-3910(94)90093-0 ↗
9. Emsley AM, Stevens GC (1994) Kinetics and mechanisms of the low-temperature degradation of cellulose. Cellulose 1:26–56. doi:10.1007/BF0081879710.1007/BF00818797 ↗
10. Funazukuri T, Hudgins RR, Silveston PL (1987) Product distribution for flash pyrolysis of cellulose in a coil pyrolyzer. J Anal Appl Pyrol 10:225–249. doi:10.1016/0165-2370(87)80005-010.1016/0165-2370(87)80005-0 ↗
11. Funazukuri T, Hudgins RR, Silveston PL (1988) Product yield correlations for cellulose flash pyrolysis. J Anal Appl Pyrol 13:103–122. doi:10.1016/0165-2370(88)80051-210.1016/0165-2370(88)80051-2 ↗
12. Gilbert R, Jalbert J, Tétreault P, Morin B, Denos Y (2008) Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 1: standard wood kraft insulation. Cellulose 16:327–338. doi:10.1007/s10570-008-9261-110.1007/s10570-008-9261-1 ↗
13. Gilbert R, Jalbert J, Duchesne S, Tétreault P, Morin B, Denos Y (2009) Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 2: thermally-upgraded insulating papers. Cellulose 17:253–269. doi:10.1007/s10570-009-9365-210.1007/s10570-009-9365-2 ↗
14. Inger E (1980) Determination of the temperature—time profile of filament pyrolyzers. J Anal Appl Pyrol 2:187–194. doi:10.1016/0165-2370(80)80030-110.1016/0165-2370(80)80030-1 ↗
15. Jalbert J, Gilbert R, Tétreault P, Morin B, Lessard-Déziel (2007) Identification of a chemical indicator of the rupture of 1,4-β-glycosidic bonds of cellulose in an oil-impregnated insulating paper system. Cellulose 14:295–309. doi:10.1007/s10570-007-9124-110.1007/s10570-007-9124-1 ↗
16. Jalbert J, Lacasse R, EL Khakani MA, Gilbert R (2009) Pulsed KrF excimer laser induced degradation of cellulose based insulating paper. Cellulose 16:863–876. doi:10.1007/s10570-009-9293-110.1007/s10570-009-9293-1 ↗
17. Jalbert J, Gilbert R, Denos Y, Gervais P (2012a) Methanol: a novel approach to power transformer asset management. IEEE Trans Power Deliv. doi:10.1109/TPWRD.2012.218595710.1109/TPWRD.2012.2185957 ↗
18. Jalbert J, Duchesne S, Rodriguez-Celis E, Tétreault P, Collin P (2012b) Robust and sensitive analysis of methanol and ethanol from cellulose degradation in mineral oils. J Chromatogr A 1256:240–245. doi:10.1016/j.chroma.2012.07.06910.1016/j.chroma.2012.07.069 ↗
19. Jalbert J, Rodriguez-Celis E, Duchesne S, Morin B, Ryadi M, Gilbert R (2015) Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 3: extension of the study under temperature conditions over 120 °C. Cellulose 22:829–848. doi:10.1007/s10570-014-0516-810.1007/s10570-014-0516-8 ↗
20. Kelly JJ (1980) Transformer fault diagnosis by dissolved-gas analysis. IEEE Trans Ind Appl IA-16:777–782. doi:10.1109/TIA.1980.450387110.1109/TIA.1980.4503871 ↗
21. Lessard MC, Lamarre C, Gendron A, Massé M (1995) Determination of paper degradation by-products by direct injection on an HPLC column. Presented at the conference on electrical insulation and dielectric phenomena, Virginia, USA, October 1995, 230–234. doi:10.1109/CEIDP.1995.48370510.1109/CEIDP.1995.483705 ↗
22. Lessard MC, Van Nifterik L, Masse M, Penneau JF, Grob R (1996) Thermal aging study of insulating papers used in power transformers. Presented at the conference on electrical insulation and dielectric phenomena, San Francisco, USA, October 1996, 20–23. doi:10.1109/CEIDP.1996.56464210.1109/CEIDP.1996.564642 ↗
23. Levchik S, Scheirs J, Camino G, Tumiatti W, Avidano M (1998) Depolymerization processes in the thermal degradation of cellulosic paper insulation in electrical transformers. Polym Degrad Stab 61:507–511. doi:10.1016/S0141-3910(97)00249-810.1016/S0141-3910(97)00249-8 ↗
24. Levy EJ, Walker JQ (1984) The model molecular thermometer: a standardization method for pyrolysis gas chromatography. J Chromatogr Sci 22:49–55. doi:10.1093/chromsci/22.2.4910.1093/chromsci/22.2.49 ↗
25. Lin Y-C, Cho J, Tompsett GA, Westmoreland PR, Huber GW (2009) Kinetics and mechanism of cellulose pyrolysis. J Phys Chem C 113:20097–20107. doi:10.1021/jp906702p10.1021/jp906702p ↗
26. Łojewska J, Miśkowiec P, Łojewski T, Proniewicz LM (2005) Cellulose oxidative and hydrolytic degradation: in situ FTIR approach. Polym Degrad Stab 88:512–520. doi:10.1016/j.polymdegradstab.2004.12.01210.1016/j.polymdegradstab.2004.12.012 ↗
27. Lundgaard LE, Hansen W, Linhjell D, Painter TJ (2004) Aging of oil-impregnated paper in power transformers. IEEE Trans Power Deliv 19:230–239. doi:10.1109/TPWRD.2003.82017510.1109/TPWRD.2003.820175 ↗
28. Moldoveanu S (1998) Analytical pyrolysis of natural organic polymers, 1st edn. Elsevier, Amsterdam
29. Oh K-K, Kim T-Y, Jeong Y-S, Hong S-I (1996) Bioconversion of cellulose to ethanol by the temperature optimized simultaneous saccharification and fermentation. Renew Energy 9:962–965. doi:10.1016/0960-1481(96)88440-010.1016/0960-1481(96)88440-0 ↗
30. Pastorova I, Botto RE, Arisz PW, Boon JJ (1994) Cellulose char structure: a combined analytical Py–GC–MS, FTIR, and NMR study. Carbohydr Res 262:27–47. doi:10.1016/0008-6215(94)84003-210.1016/0008-6215(94)84003-2 ↗
31. Perveen S, Hussain Z, Khan KM (2008) Comparison of the pyrolysates of glucose, sucrose, starch and cellulose. J Chem Soc Pak 30:142–146
32. Piskorz J, Radlein D, Scott DS (1986) On the mechanism of the rapid pyrolysis of cellulose. J Anal Appl Pyrol 9:121–137. doi:10.1016/0165-2370(86)85003-310.1016/0165-2370(86)85003-3 ↗
33. Rocha NR de AF, Barros MA, Fischer J, Filho UC, Cardoso VL (2013) Ethanol production from agroindustrial biomass using a crude enzyme complex produced by Aspergillus niger. Renew Energy 57:432–435. doi:10.1016/j.renene.2013.01.05310.1016/j.renene.2013.01.053 ↗
34. Rodriguez-Celis E, Jalbert J, Duchesne S, Noirhomme B, Lessard MC, Ryadi M (2012) Chemical markers use for diagnosis and life estimation of power transformers, a preliminary study of their origins. Presented at the CIGRE Canada conference, Montreal, Canada, September 2012
35. Ryadi M, Tanguy A, Jalbert J, Rajotte C (2011) Alcohols based ageing chemical markers for the diagnosis of transformer cellulosic insulation. Presented at the CIGRE A2 and D1 Joint Colloquium PS2-0-4, Kyoto, Japan, September 2011
36. Schaut A, Autru S, Eeckhoudt S (2011) Applicability of methanol as new marker for paper degradation in power transformers. IEEE Trans Dielectr Electr Insul 18:533–540. doi:10.1109/TDEI.2011.573945910.1109/TDEI.2011.5739459 ↗
37. Shafizadeh F (1982) Introduction to pyrolysis of biomass. J Anal Appl Pyrol 3:283–305. doi:10.1016/0165-2370(82)80017-X10.1016/0165-2370(82)80017-X ↗
38. Shafizadeh F, Fu YL (1973) Pyrolysis of cellulose. Carbohydr Res 29:113–122. doi:10.1016/S0008-6215(00)82074-110.1016/S0008-6215(00)82074-1 ↗
39. Srinivas D, Jagannadha Rao K, Théodore K, Panda T (1995) Direct conversion of cellulosic material to ethanol by the intergeneric fusant Trichoderma reesei QM 9414/Saccharomyces cerevisiae NCIM 3288. Enzyme Microbial Technol 17:418–423. doi:10.1016/0141-0229(94)00093-710.1016/0141-0229(94)00093-7 ↗
40. Tamura R, Anetai H, Ishii T, Kawamura T (1981) Diagnosis of ageing deterioration of insulating paper. Trans Inst Electr Eng Jpn 101:30–3610.1002/eej.4391010406 ↗
41. Unsworth J, Mitchell F (1990) Degradation of electrical insulating paper monitored with high performance liquid chromatography. IEEE Trans Electr Insul 25:737–746. doi:10.1109/14.5709810.1109/14.57098 ↗
42. Wayman M, Chen S, Doan K (1992) Bioconversion of waste paper to ethanol. Process Biochem 27:239–245. doi:10.1016/0032-9592(92)80024-W10.1016/0032-9592(92)80024-W ↗
43. Whitmore PM, Bogaard J (1994) Determination of the cellulose scission route in the hydrolytic and oxidative degradation of paper. Restaurator 15:26–45. doi:10.1515/rest.1994.15.1.2610.1515/rest.1994.15.1.26 ↗