Synergistic enhancement effect of moisture and aging on frequency dielectric response of oil-immersed cellulose insulation and its degree of polymerization evaluation using dielectric modulus
Source abstract
Abstract
Oil-immersed cellulose insulation is the heart of the power transformer, which will will gradually deteriorate in the operation process of transformer. Therefore, accurately evaluating the aging condition of the oil-immersed cellulose insulation is important for maintaining safe and stable operation of transformer. In this paper, the synergistic effect of moisture and aging on frequency dielectric spectroscopy (FDS) of oil-immersed cellulose insulation was analyzed in depth using the modified cole–cole model. A novel degree of polymerization (DP) evaluation method for oil-immersed cellulose insulation based on the dielectric modulus analysis and its curve translation method was proposed. Results show that the higher the moisture content and the lower the DP, the greater the frequency dielectric parameters, the smaller the α relaxation time, the greater the DC conductivity and hopping conductivity of the oil-immersed cellulose insulation. The novel DP evaluation method for oil-immersed cellulose insulation based on calculating the integral area of the imaginary part of dielectric modulus A(DP–mc%) and translating the A(DP–mc%) curve was proposed, which could simultaneously consider the synergistic effect of moisture and aging on FDS. The novel DP evaluation method for the oil-immersed cellulose insulation is suitable for moisture range is 0.5–5%, and the DP range is 250–1300. The verified effectiveness of the novel DP evaluation method presents that it is ideal for transformer aging condition assessment, which is superior to the existing evaluation methods.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Power Transformer Diagnostics and Insulation · High voltage insulation and dielectric phenomena · Islanding Detection in Power Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Gafvert U (2005) Influence of geometric structure and material properties on dielectric frequency response of composite oil cellulose insulation. In: Proceedings of 2005 international symposium on electrical insulating materials, pp 73–7610.1109/ISEIM.2005.193329 ↗
2. Gao J, Yang LJ, Wang YY, Qi CL, Hao J, Liu JF (2015) Quantitative evaluation of aging condition of oil-paper insulation using frequency domain characteristic extracted from modified cole–cole model. IEEE Trans Dielectr Electr Insul 22(5):2694–270210.1109/TDEI.2015.005067 ↗
3. Gielniak J, Graczkowski A, Moscicka-Grzesiak H (2011) Does the degree of cellulose polymerization affect the dielectric response? IEEE Trans Dielectr Electr Insul 18(5):1647–165010.1109/TDEI.2011.6032835 ↗
4. Gielniak J, Graczkowski A, Moranda H (2013) Moisture in cellulose insulation of power transformers-statistics. IEEE Trans Dielectr Electr Insul 20(3):981–98710.1109/TDEI.2013.6518968 ↗
5. Hao J, Liao RJ, Chen G, Ma ZQ, Yang LJ (2012) Quantitative analysis aging status of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current. IEEE Trans Dielectr Electr Insul 19(1):188–19910.1109/TDEI.2012.6148518 ↗
6. Jadav RB, Ekanayake C, Saha TK (2013) Understanding the impact of moisture and aging of transformer insulation on frequency domain spectroscopy. IEEE Trans Dielectr Electr Insul 21(1):369–37910.1109/TDEI.2013.003984 ↗
7. Koch M, Prevost T (2012) Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation. IEEE Trans Dielectr Electr Insul 19:1908–191510.1109/TDEI.2012.6396947 ↗
8. Liao RJ, Hao J, Chen G, Yang LJ (2012) Quantitative analysis of aging condition of oil-paper insulation by frequency domain spectroscopy. IEEE Trans Dielectr Electr Insul 19(3):821–83010.1109/TDEI.2012.6215085 ↗
9. Liao RJ, Liu JF, Wang K, Hao J, Ma ZQ, Gao J, Lv YD (2015) Quantitative analysis of insulation condition of oil-paper insulation based on frequency domain spectroscopy. IEEE Trans Dielectr Electr Insul 22(1):322–33410.1109/TDEI.2014.004490 ↗
10. Linhjell D, Lundgaard LE, Gafvert U (2007) Dielectric response of mineral oil impregnated cellulose and the impact of aging. IEEE Trans Dielectr Electr Insul 14:156–16910.1109/TDEI.2007.302884 ↗
11. Liu JF, Fan XH, Zheng HB, Zhang YY, Zhang CH, Lai B, Wang J, Ren G (2019a) Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method. Cellulose 26(6):3891–390810.1007/s10570-019-02331-1 ↗
12. Liu JF, Fan XH, Zhang YY, Zheng HB, Zhu MZ (2019b) Quantitative evaluation for moisture content of cellulose insulation material in paper/oil system based on frequency dielectric modulus technique. Cellulose 27:2343–235610.1007/s10570-019-02820-3 ↗
13. Mo Y, Yang LJ, Hou W, Zou TT, Huang Y, Zheng X, Liao RJ (2019) Preparation of cellulose insulating paper of low dielectric constant by OAPS grafting. Cellulose 26:7451–746810.1007/s10570-019-02570-2 ↗
14. Ohki Y (2015) Dielectric relaxation phenomena of several insulating polymers analyzed by electric modulus spectra. In: IEEE international conference on the properties & applications of dielectric materials, Sydney, Australia, pp 192–19510.1109/ICPADM.2015.7295241 ↗
15. Saha TK, Purkait P (2008) Understanding the impacts of moisture and thermal aging on transformer’s insulation by dielectric response and molecular weight measurements. IEEE Trans Dielectr Electr Insul 15:568–58210.1109/TDEI.2008.4483479 ↗
16. Tang C, Zhang S, Wang X, Hao J (2018) Enhanced mechanical properties and thermal stability of cellulose insulation paper achieved by doping with melamine-grafted nano-SiO2. Cellulose 25(6):3619–363310.1007/s10570-018-1813-4 ↗
17. Tripathi N, Shukla A, Thakur AK, Marx DT (2020) Dielectric modulus and conductivity scaling approach to the analysis of ion transport in solid polymer electrolytes. Polym Eng Sci 60(2):297–30510.1002/pen.25283 ↗
18. Tian FQ, Ohki Y (2014) Electric modulus powerful tool for analyzing dielectric behavior. IEEE Trans Dielectr Electr Insul 21:929–93110.1109/TDEI.2014.6832233 ↗
19. Yang LJ, Liao RJ, Sun CX, Zhu MZ (2012) Influence of vegetable oil on the thermal aging of transformer paper and its mechanism. IEEE Trans Dielectr Electr Insul 18:2059
20. Yang LJ, Zou TT, Deng BF, Zhang HB, Mo Y, Peng P (2019) Assessment of oil-paper insulation aging using frequency domain spectroscopy and moisture equilibrium curves. IEEE Access 7:45670–4567810.1109/ACCESS.2019.2906379 ↗
21. Zhou YX, Huang M, Chen WJ, Lu LC, Jin FB, Huang JW (2015) Space charge behavior evolution with thermal aging of oil-paper insulation. IEEE Trans Dielectr Electr Insul 22(3):1381–138810.1109/TDEI.2015.7116326 ↗
22. Zhang MZ, Liu J, Jia HF, Chen QG, Lv JL, Chen X (2019) Modelling the low-frequency electrode dielectric response based on transformer equivalent oil-paper insulation model. IET SCI MEAS TECHNOL 13(5):700–70710.1049/iet-smt.2018.5495 ↗