journal article·2018-01Open access

Corrosion rate of carbon steel in carbonated concrete – A critical review

M. Stefanoni, U. Angst, B. Elsener

Abstract

Abstract Reinforced concrete with lower environmental footprint (lower CO2 emission) can be obtained by reducing the clinker content in the cements. As the carbonation of concrete is faster, corrosion of steel in carbonated concrete during the propagation phase is becoming important both for science and practice. The present literature review summarizes the state of the art, reporting corrosion rate data for a broad range of cement types, w/b ratios and environmental conditions. Correlations between corrosion rate and the main influencing parameters are elaborated and discussed. It confirms that the corrosion rate of steel in carbonated concrete is not under ohmic control. More important are the degree of pore saturation and the effective steel area in contact with water filled pores. It also emerges that the new blended cements have to be systematically studied with respect to the corrosion behavior of steel in carbonated concrete in order to make reliable service life prediction.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Bertolini · 2013
2. A review of carbonation in reinforced concrete
3. Olivier · 2015
4. Present and future durability challenges for reinforced concrete structures10.1002/maco.201206898 ↗
5. Eco-efficiency of the world cement industry: a data envelopment analysis10.1016/j.enpol.2011.02.057 ↗
6. Emission reduction of greenhouse gases from the cement industry
7. Sustainable Cement Production—present and Future10.1016/j.cemconres.2011.03.019 ↗
8. Technology map of the European Strategic Energy Technology plan (SET-Plan)
9. Page · 1975 · 514
10. Carbonation resistance of GGBS concrete10.1680/jmacr.15.00449 ↗
11. Carbonation resistance of fly ash concrete10.1680/macr.15.00204 ↗
12. Bamforth · 2004
13. Relation between carbonation resistance, mix design and exposure of mortar and concrete10.1016/j.cemconcomp.2015.04.020 ↗
14. Accelerated carbonation of concrete with high content of mineral additions: effect of interactions between hydration and drying10.1016/j.cemconres.2012.10.008 ↗
15. Effect of supplementary cementing materials on concrete resistance against carbonation and chloride ingress10.1016/S0008-8846(99)00249-5 ↗
16. Modeling carbonation for corrosion risk prediction of concrete structures10.1016/S0008-8846(02)00728-7 ↗
17. Service life of RC structures: carbonation induced corrosion. Prescriptive vs. performance-based methodologies10.1016/j.conbuildmat.2009.08.039 ↗
18. Carbonation service life modelling of RC structures for concrete with Portland and blended cements10.1016/j.cemconcomp.2012.10.007 ↗
19. Internal chemical evolution of the constitution of blended cements10.1016/0008-8846(88)90042-7 ↗
20. Supplementary cementitious materials10.2138/rmg.2012.74.6 ↗
21. Corrosion of reinforcing bars in carbonated concrete10.1179/bcj.1980.15.3.135 ↗
22. Corrosion rate of reinforcements during accelerated carbonation of mortar made with different types of cement
23. Factores controlantes de la velocidad de corrosion de las amraduras embebidas en morteros de cement
24. Effect of curing conditions on carbonation of concrete with fly ash and the corrosion of reinforcement in long term tests
25. Effect of cement type and cement proportion in the corrosion rate of rebars embedded in carbonates mortar10.3989/mc.1987.v37.i205.874 ↗
26. Approach to the effect of concrete resistivity in the corrosion of rebars in concrete10.3989/mc.1987.v37.i207.859 ↗
27. Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types10.1016/0008-8846(88)90091-9 ↗
28. Karbontisierungszellen – ein Beitrag zur Korrosion von Stahl in karbonatisiertem Beton10.1002/maco.19880390303 ↗
29. Carbonation of concrete with fly ash and corrosion of reinforcements in 20years field tests, in fly ash, silica fume, slag and natural pozzolans in concrete
30. Influence of surface treatments on corrosion rates of steel in carbonated concrete
31. The use of superplastisizers as steel corrosion reducers in reinforced concrete
32. A galvanic sensor for monitoring corrosion of steel in carbonated concrete10.1680/macr.1991.43.156.149 ↗
33. Factors affecting the corrosion rate of steel in carbonated mortars10.1016/0010-938X(91)90048-T ↗
34. Pulverized-fuel ash concrete: carbonation induced reinforcement corrosion rates10.1680/istbu.1992.20293 ↗
35. Branca · 1992 · 245
36. Carbonation and chloride induced corrosion of reinforcement in fly ash concretes
37. Influence of the degree of pore saturation on the resistivity of concrete and the corrosion rate of steel reinforcement10.1016/0008-8846(93)90102-F ↗
38. A study of carbonation induced corrosion10.1680/macr.1994.46.166.23 ↗
39. Cao · 1994 · 215
40. The corrosion of steel reinforcement in carbonated concrete under different humidity regimes10.1557/PROC-370-471 ↗
41. Some effects of cement and curing upon carbonation and reinforcement corrosion in concrete10.1007/BF02486162 ↗
42. Performance of Reinforced Blast Furnace Slag Cement Concrete Specimens After 10-years' Exposure in Bahrain
43. Saguez · 1997
44. Moreno · 1998
45. Castro · 1999
46. Rates of carbonation and reinforcement corrosion in high alumina cement concrete10.1680/macr.2000.52.6.433 ↗
47. Control of reinforcement corrosion by surface treatment of concrete10.1680/stbu.2000.140.1.85 ↗
48. Environmental influences on linear polarization corrosion rate measurements in reinforced concrete10.1016/S0963-8695(01)00008-1 ↗
49. Effects of carbontion on mechanical properties and durability of concrete using accelerated testing method10.51400/2709-6998.2296 ↗
50. Corrosion behaviour of rebars in fly ash mortar exposed to carbon dioxied and chlorides10.1016/S0958-9465(01)00025-7 ↗
51. Cement content influence in rebar corrosion in carbonated mortars10.3989/mc.2003.v53.i271-272.296 ↗
52. Corrosion rates from carbonated concrete specimens
53. Varjonen · 2004 · 31 · 1
54. Performance of supplementary cementitious materials in concrete resistivity and corrosion monitoring evaluations
55. Carbonation induced corrosion in urban concrete structures
56. Performance of galvanized reinforcing steel in carbonated concrete specimens
57. Influence of Cement type and temperature on the rate of corrosion of steel in concrete exposed to carbonation
58. Influence of cement type and temperature on the rate of corrosion of steel in concrete exposed to carbonation10.5006/1.3278306 ↗
59. Influence of cement content on corrosion resistance10.1680/coma.2008.161.1.31 ↗
60. Residual service life of concrete façade structures with reinforcement in carbonated concrete in Nordic climate
61. Carbonation rate and reinforcing steel corrosion rate of OPC/FC3R/FA mortars under accelerated conditions10.1680/adcr.2007.00008 ↗
62. Carbonation induced reinforcement corrosion in silica fume concrete10.1016/j.conbuildmat.2008.08.005 ↗
63. Corrosion resistance performance of high volume fly-ash self-compacting concrete10.1680/macr.2006.00016 ↗
64. The effect of processed fly ash on the durability and the corrosion of steel rebars embedded in cement-modified fly ash mortars10.1016/j.cemconcomp.2009.11.006 ↗
65. Carbonation rate and reinforcing steel corrosion of concretes with recycled aggregates and supplementary cementitious materials10.1016/S1452-3981(23)13438-9 ↗
66. Kujur · 2012
67. Aspects of carbonation of reinforced concrete
68. Effects of some mineral additions to portland cement on reinforcement corrosion10.1016/j.cemconres.2013.06.004 ↗
69. Corrosion process of reinforced concrete by carbonation in a natural environment and an accelerated test chamber10.1016/S1452-3981(23)12946-4 ↗
70. Corrosion behavior of steel reinforcement in concrete with recycled aggregates, fly ash and spent cracking catalyst10.3390/ma7043176 ↗
71. Service life evaluation of an existing reinforced concrete structure based on carbonation induced corrosion
72. Influence of pre-existing oxide layer and interface condition with carbonated concrete on active reinforcing steel corrosion10.1002/maco.201307195 ↗
73. Corrosion performance of blended concretes exposed to different aggressive environments10.1016/j.conbuildmat.2016.06.038 ↗
74. Chemical changes and phase analysis of OPC pastes carbonated at different CO2 concentrations10.1617/s11527-008-9399-1 ↗
75. Carbonation of concrete: the role of CO2 concentration, relative humidity and CO2 buffer capacity10.1617/s11527-016-0917-2 ↗
76. Calibration of the electrochemical methods for the corrosion rate measurement of steel in concrete
77. Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcement10.1002/maco.200403841 ↗
78. Relationship between conductivity of concrete and corrosion of reinforcing bars10.1179/000705989798270027 ↗
79. Rebar corrosion in carbonated concrete exposed to variable humidity conditions. Interpretation of Tuutti's curve10.1016/j.corsci.2009.04.029 ↗
80. Relationship between concrete resistivity and corrosion rate–a literature review10.1016/j.cemconcomp.2013.03.019 ↗
81. Electrical conductivity, diffusion, and permeability of portland cement-based mortars10.1016/S0008-8846(00)00281-7 ↗
82. Accelerated carbonation of concrete with high content of mineral additions: effect of interactions between hydration and drying10.1016/j.cemconres.2012.10.008 ↗
83. Effect of supplementary cementing materials on concrete resistance against carbonation and chloride ingress10.1016/S0008-8846(99)00249-5 ↗
84. Quantitative kinetics of Pozzolanic reactions in coal/cofired biomass fly ashes and calcium hydroxide (CH) mortars10.1016/j.conbuildmat.2013.10.057 ↗
85. Investigation of blended cement hydration by isothermal calorimetry and thermal analysis10.1016/j.cemconres.2004.10.027 ↗
86. Reactivity of blast-furnace slag in portland cement blends hydrated under different conditions10.1016/S0008-8846(01)00587-7 ↗
87. Hydration of slag-blended cements10.1016/j.cemconcomp.2012.05.007 ↗
88. Pore structure characteristics affecting the permeability of cement paste containing fly ash10.1016/0008-8846(85)90094-8 ↗
89. Benefits of slag and fly ash10.1016/0950-0618(95)00014-3 ↗
90. Tuutti · 1982
91. Autogenous shrinkage in high-performance cement paste: an evaluation of basic mechanisms10.1016/S0008-8846(02)00890-6 ↗
92. Water vapour sorption experiments on hardened cementitious materials. Part I: essential tools for analysis of typical behaviour and its relation to the pore structure10.1016/j.cemconres.2006.11.017 ↗
93. Pore classification in the characterization of porous materials: a perspective10.2478/s11532-007-0017-9 ↗
94. Gjörv, Vennesland and El-Busaidy · 1977 · 581
95. The atmospheric corrosion of iron10.1002/bbpc.19900940603 ↗
96. Similarity between atmospheric/underground corrosion and reinforcement corrosion
97. Process control of reinforcement corrosion in concrete. Part 1: effect of corrosion products10.1016/j.conbuildmat.2014.12.083 ↗
98. Process control of reinforcement corrosion in concrete. Part 2: time-dependent dominating factors under different environmental conditions10.1016/j.conbuildmat.2014.09.103 ↗
99. The role of rusts in corrosion and corrosion protection of iron and steel10.1016/j.corsci.2008.03.008 ↗
100. The effect of pH on the kinetics of spontaneous Fe (II) oxidation by O2 in aqueous solution–basic principles and a simple heuristic description10.1016/j.chemosphere.2007.02.015 ↗