journal article·2020-02

A 3D petrographic analysis for concrete freeze-thaw protection

Yu Song, Robbie M. Damiani, Chuanyue Shen, Daniel I. Castaneda, David A. Lange

Publisher page

Abstract

Abstract Petrographic analysis is routinely implemented to measure air void parameters for predicting freeze-thaw durability of concrete. The 1D or 2D measurements obtained from polished concrete sections are used to infer 3D protection of the paste. Since an arbitrary point in a section view may be partially protected by air voids that are not intersected, a stereological model is proposed to consider both intersected and un-intersected voids. The model is tested with a group of concrete mixtures with varying air entrainment, mix proportion, and aggregate type. As compared with the 2D analysis, this 3D analysis indicates a higher percent of cement paste being protected. When equating the protection range to Powers' spacing factor, it is found that roughly 98% of paste is protected in 3D. Findings in this study also align with results obtained by other authors using numerical simulation and computed tomography. This model offers a realistic concrete freeze-thaw assessment.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete and Cement Materials Research · Innovative concrete reinforcement materials · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Theory of volume changes in hardened portland cement paste during freezing
2. Powers · 1949
3. Mechanisms of frost damage
4. Characterisation of air-void systems in concrete
5. K. Hover, Air content and unit weight of hardened concrete, in: Significance Tests Prop. Concr. Concr. Mate Rials, ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428–2959, n.d.: pp. 296-296–19. https://doi.org/10.1520/STP36427S.10.1520/STP36427S ↗
6. Effect of entrained air voids on the microstructure and mass transport properties of concrete10.1016/j.cemconres.2011.06.013 ↗
7. S. Rath, N. Puthipad, A. Attachaiyawuth, M. Ouchi, Critical size of entrained air to stability of air volume in mortar of self-compacting concrete at fresh stage, J. Adv. Concr. Technol. (2017). doi:https://doi.org/10.3151/jact.15.29.10.3151/jact.15.29 ↗
8. Effect of air entrainment on shrinkage of blended cements concretes10.1016/j.conbuildmat.2015.09.018 ↗
9. Some recent problems with air-entrained concrete10.1520/CCA10104J ↗
10. A hypothesis concerning the effects of macro-porosity on mechanical properties of concrete
11. Optimization and performance of air-entrained, self-consolidating concrete
12. Air-void stability in self-consolidating concrete
13. ACI · 2008
14. Astm C 457 · 2013 · 1
15. Mechanisms of air entrainment in concrete10.1016/j.cemconres.2004.07.026 ↗
16. Pigeon · 1995
17. Probabilistic evaluation of concrete freeze-thaw design guidance10.1617/s11527-018-1259-z ↗
18. ACI Committee 212 · 2010
19. CSA A23.1-14/A23.2-14 · 2014
20. A numerical test of air void spacing equations10.1016/S1065-7355(98)00007-8 ↗
21. The stereological and statistical properties of entrained air voids in concrete: A mathematical basis for air void system characterization
22. A method for analyzing void distribution in air-entrained concrete10.1520/CCA10263J ↗
23. Air void structure and frost resistance: a challenge to Powers’ spacing factor10.1617/s11527-013-0102-9 ↗
24. Mean spacing of air voids in hardened concrete
25. The use of the flow length concept to assess the efficiency of air entrainment with regards to frost durability: part I—description of the test method10.1520/CCA10308J ↗
26. Quantifying the distribution of paste-void spacing of hardened cement paste using X-ray computed tomography10.1016/j.matchar.2012.08.008 ↗
27. Landis E.N., Corr D.J., Three dimensional analysis of air void systems in concrete, Meas. Monit. Model. Concr. Prop, Springer, Netherlands, Dordrecht, n.d., pp. 517–524, https://doi.org/10.1007/978-1-4020-5104-3_63.10.1007/978-1-4020-5104-3_63 ↗
28. Obtaining the spacing factor of microporous concrete using high-resolution dual energy X-ray micro CT10.1016/j.cemconres.2016.08.008 ↗
29. Determination of the paste to void proximity distribution in two dimensions from a cross-section through a concrete specimen
30. Hardened concrete air void analysis with a flatbed scanner
31. Protected Paste Volume (PPV) as a parameter linking the air-pore structure in concrete with the frost resistance results10.1016/j.conbuildmat.2016.02.196 ↗
32. The protected paste volume concept using new air-void measurement and distribution techniques
33. ASTM International · 2013
34. Advances in measuring air-void parameters in hardened concrete using a flatbed scanner10.1520/JTE20150424 ↗
35. Russ · 2000
36. An image analysis procedure to quantify the air void system of mortar and concrete10.1617/s11527-014-0381-9 ↗
37. A 3D stereological model for investigating air voids in a concrete scan (under review)
38. Air-void structure, strength, and permeability of wet-mix shotcrete before and after shotcreting operation: the influences of silica fume and air-entraining agent10.1016/j.cemconcomp.2016.03.012 ↗
39. Vibration of fresh concrete understood through the paradigm of granular physics10.1016/j.cemconres.2018.09.005 ↗
40. Examining the frost resistance of high performance concrete10.1016/j.conbuildmat.2008.04.006 ↗
41. A probabilistic technique for entrained air void analysis in hardened concrete10.1016/j.cemconres.2014.01.023 ↗
42. The durability characteristics of high performance concrete: a review10.1016/S0958-9465(02)00081-1 ↗
43. Practical considerations pertaining to the Microscopical determination of air void characteristics of hardened concrete (ASTM C 457 standard)
44. Automated air void analysis of hardened concrete - a round Robin study10.1016/j.cemconres.2006.03.005 ↗
45. Hardened concrete air void analysis with a flatbed scanner10.3141/1775-06 ↗
46. Concrete incorporating high volumes of ASTM class F Fly ash10.1520/CCA10088J ↗
47. Characterization of multi-scale porosity in cement paste by advanced ultrasonic techniques10.1016/j.cemconres.2006.09.016 ↗
48. Precision of the air void characteristics measurement by ASTM C 457: results of an interlaboratory test program10.1139/l96-919 ↗
49. Estimating the 95th percentile of the paste-void spacing distribution in hardened cement paste containing air entrainment
50. Protected paste volume in concrete: extension to internal curing using saturated lightweight fine aggregate10.1016/S0008-8846(99)00178-7 ↗
51. Revisiting the protected paste volume concept for internal curing of high-strength concretes10.1016/j.cemconres.2011.05.007 ↗
52. Self-healing concrete by use of microencapsulated bacterial spores10.1016/j.cemconres.2013.11.009 ↗
53. A mathematical model for the Pessimum size effect of ASR in concrete