journal article·2021-12

Bond of steel-mortar interface interfered by stray current

Zhipei Chen, Dessi A. Koleva, Erik Schlangen

Publisher page

Abstract

Abstract The focus of this work is to present test results on the bond of steel-mortar interface undergoing stray current. The bond strength, derived by pull-out tests, is correlated to the electrochemical response of the steel rebar and the properties of the mortar bulk matrix. The effects of curing regimes (in terms of duration of curing) and starting point of stray current are also investigated. It is found that stray current exerts bond degradation of the steel-mortar interface in all investigated cases, irrespective of the presence or absence of a corrodent (Cl−) in the external medium. For the ease of operation in lab tests, the stray current is generally simulated by anodic polarization, although fundamentally, the stray current effect on the steel surface is composed of both anodic and cathodic polarizations. Hence this work also differentiates the effects of stray current on steel-mortar bond, versus the effects of anodic polarization.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (77)

Show source-provided references
1. A study of the bond degradation of rebar due to cathodic protection current10.1016/S0008-8846(01)00740-2 ↗
2. Corrosion influence on bond in reinforced concrete10.1016/j.cemconres.2004.04.006 ↗
3. An experimental study on the bond strength between reinforcement bars and concrete as a function of concrete cover, strength and corrosion level10.1016/j.cemconres.2012.01.003 ↗
4. Corrosion behaviour of steel in concrete in the presence of stray current10.1016/j.corsci.2006.05.048 ↗
5. Electrochemical tests in reinforced mortar undergoing stray current-induced corrosion
6. A review on stray current-induced steel corrosion in infrastructure10.1515/corrrev-2017-0009 ↗
7. A. Susanto, D.A. Koleva, O. Copuroglu, K. van Beek, K. van Breugel, Mechanical, Electrical and microstructural properties of cement-based materials in conditions of stray current flow, J. Adv. Concrete Technol., 11 (2013) 119–134.10.3151/jact.11.119 ↗
8. Effects of DC stray current on concrete permeability10.1061/(ASCE)MT.1943-5533.0001362 ↗
9. Effect of stray current on stability of bound chlorides in chloride and sulfate coexistence environment10.1016/j.conbuildmat.2018.11.010 ↗
10. Stray current affects the release of bound chloride ions in hydrated cement paste10.20964/2018.06.77 ↗
11. Evaluation, the deterioration of cement mortar under the coupled conditions of stray current and sulfate
12. Influence of stray current on chloride ion migrates in concrete
13. Influence of frequency of alternating current on corrosion of steel in seawater
14. Measurement of ground currents leaking from DC electric traction, electric power engineering (EPE)
15. Laboratory testing on the influence of alternated current on steel corrosion
16. Interaction between corrosion crack width and steel loss in RC beams corroded under load10.1016/j.cemconres.2010.03.010 ↗
17. Bond behaviour of normal/recycled concrete and corroded steel bars10.1016/j.conbuildmat.2013.06.091 ↗
18. Degradations of reinforced concrete structures due to d.c. and a.c. stray currents
19. Simulation experiment of loading influence to reinforcement corrosion affected by stray current and salt solution
20. Distribution of the stray current of rebar in the ballast bed10.4028/www.scientific.net/AMM.226-228.2147 ↗
21. Effect of electrical field on TSA failure of cement-based materials10.1016/j.cemconres.2016.09.011 ↗
22. Stray current control by a new approach based on current monitoring on a potential probe10.1080/1478422X.2017.1292202 ↗
23. Stray current induced corrosion of steel fibre reinforced concrete10.1016/j.cemconres.2017.08.004 ↗
24. J. Tinnea, R. Tinnea, D. Burke, L. Nelson, S. Cochran, E. Anderson, L. Pham, Evaluating Concrete Resistivity: Reducing Stray Current from dc Streetcars, NACE International.
25. Method of sacrificial anode dual transistor-driving in stray current field10.1016/j.corsci.2015.06.006 ↗
26. Chloride-induced stray current corrosion of Q235A steel and prediction model10.1016/j.conbuildmat.2019.05.113 ↗
27. An experimental corrosion investigation of coupling chloride ions with stray current for reinforced concrete10.4028/www.scientific.net/AMM.166-169.1987 ↗
28. Corrosion fatigue of reinforced concrete in the presence of stray current
29. Study on corrosion and delamination behavior of X70 steel under the coupling action of AC-DC interference and stress10.20964/2019.02.46 ↗
30. Experimental study on stray current corrosion of coated pipeline steel10.1016/j.jngse.2015.10.022 ↗
31. Corrosion of graphite-fiber-reinforced composites IIAnodic polarization damage
32. Prediction model of corrosion current density induced by stray current based on QPSO-driven neural network
33. The influence of DC stray current on pipeline corrosion10.1007/s12182-015-0064-3 ↗
34. Experimental observations of stray current effects on steel fibres embedded in mortar10.1016/j.corsci.2013.03.014 ↗
35. Research on corrosion characteristics of stainless steel bar in stray current and chloride ion coexisted environment10.4028/www.scientific.net/AMR.261-263.56 ↗
36. Fundamental aspects of stray current corrosion on buried pipeline10.4028/www.scientific.net/AMR.146-147.70 ↗
37. Corrosion behavior of reinforcing steel undergoing stray current and anodic polarization10.3390/ma14020261 ↗
38. Standard practice for preparing, cleaning, and evaluating corrosion test specimens
39. Local bond strength of vitreous enamel coated rebar to concrete10.1016/j.conbuildmat.2012.04.067 ↗
40. Bond strength prediction for reinforced concrete members with highly corroded reinforcing bars10.1016/j.cemconcomp.2008.03.006 ↗
41. Confinement effects on the steel-concrete bond strength and pull-out failure10.1016/j.engfracmech.2012.10.013 ↗
42. Electrochemical polarization: I. a theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
43. Corrosion: of reinforcing bars in carbonated concrete10.1179/bcj.1980.15.3.135 ↗
44. Quantitative measurements of corrosion rate of reinforcing steels embedded in concrete using polarization resistance measurements10.1002/maco.19780290804 ↗
45. Standard test method for comparing concrete on the basis of the bond developed with reinforcing steel, ASTM annual book of standards: Section 4. Construction, (1991).
46. Stray current-induced development of cement-based microstructure in water-submerged, Ca(OH)2-submerged and sealed conditions10.3151/jact.15.244 ↗
47. The effect of water-to-cement ratio and curing on material properties of mortar specimens in stray current conditions10.3151/jact.15.627 ↗
48. The influence of silicate and sulphate anions on the anodic corrosion and the transpassivity of iron and silicon-rich steel in concentrated KOH solution10.1016/j.corsci.2012.07.019 ↗
49. A RRDE study of the electrochemical behavior of iron in solutions containing silicate and sulphate at pH 10-1310.1016/S0010-938X(98)00149-8 ↗
50. Early steps in the anodic oxidation of iron in aqueous solution10.5006/1.3580843 ↗
51. The transpassive dissolution mechanism of 316L stainless steel10.1016/j.electacta.2009.01.040 ↗
52. Steel corrosion resistance in model solutions, containing waste materials10.1016/j.electacta.2011.10.010 ↗
53. Microstructural changes in a cementitious membrane due to the application of a DC electric field10.1080/10934520801974632 ↗
54. Impedance spectroscopy study of saturated mortar samples10.1016/j.electacta.2007.10.042 ↗
55. Equivalent circuit model for AC electrochemical impedance spectroscopy of concrete10.1016/S0008-8846(00)00400-2 ↗
56. Corrosion by chlorides in reinforced concrete: determination of chloride concentration threshold by impedance spectroscopy10.1016/j.cemconres.2003.11.009 ↗
57. Corrosion behaviour of rebars in fly ash mortar exposed to carbon dioxide and chlorides10.1016/S0958-9465(01)00025-7 ↗
58. Equivalent circuit for modelling the steel-concrete interface. I. Experimental evidence and theoretical predictions10.1016/S0010-938X(98)00036-5 ↗
59. The importance of geometrical considerations in the measurement of steel corrosion in concrete by means of AC impedance10.1016/0010-938X(95)00095-2 ↗
60. Analysis of local corrosion of large metallic structures or reinforced concrete structures by electrochemical impedance spectroscopy (EIS)10.1016/0013-4686(90)80012-D ↗
61. Algorithm for extracting corrosion parameters from the response of the steel-concrete system to a current pulse10.1149/1.1643737 ↗
62. Electrochemical performance of steel in cement extract and bulk matrix properties of cement paste in the presence of Pluronic 123 micelles10.1007/s10853-012-7037-3 ↗
63. The time-domain response of a corroding system with constant phase angle interfacial component: application to steel in concrete10.1016/0010-938X(95)00017-E ↗
64. Corrosion macrocell behavior of reinforcing steel in partially submerged concrete columns10.1016/S0010-938X(02)00087-2 ↗
65. Blagojevic · 2014
66. Advances in electrochemical impedance measurements in reinforced concrete10.4028/www.scientific.net/MSF.192-194.843 ↗
67. A.A. Almusallam, A.S. Al-Gahtani, A.R. Aziz, Rasheeduzzafar, Effect of reinforcement corrosion on bond strength, Constr. Build. Mater., 10 (1996) 123–129.10.1016/0950-0618(95)00077-1 ↗
68. Effect of cathodic protection on steel–concrete bond strength using ion migration measurements10.1016/j.cemconcomp.2011.09.014 ↗
69. Mechanism of damage for the alkali-silica reaction10.1016/j.cemconres.2005.06.003 ↗
70. Relation of expansion due to alkali silica reaction to the degree of reaction measured by SEM image analysis10.1016/j.cemconres.2007.04.016 ↗
71. The influence of potassium-sodium ratio in cement on concrete expansion due to alkali-aggregate reaction10.1016/j.cemconres.2008.05.004 ↗
72. Expansion of concrete due to alkali-silica reaction
73. Different manifestations of the alkali-silica reaction in concrete according to the reaction kinetics of the reactive aggregate10.1016/j.cemconres.2005.12.022 ↗
74. Numerical simulation and experimental investigation of the stray current corrosion of viaducts in the high-speed rail transit system10.1016/j.conbuildmat.2017.09.114 ↗
75. Cathodic protection for prestressed concrete structures10.1016/S0950-0618(97)00014-7 ↗
76. Changes in concrete pore size distribution due to electrochemical chloride migration trials
77. Preliminary experimental study on the deterioration of cementitious materials by an acceleration method10.1016/0029-5493(92)90290-C ↗