Hybrid modified ferrocement under sustained load in flowing sulphuric acid solution
Source abstract
Abstract
Abstract As a part of a research programme on reinforcement corrosion, the behavior of a soluble glass-polyvinyl acetate hybrid modified ferrocement under sustained flexural load was investigated in flowing sulphuric acid solution to better simulate the site condition. Test results showed that corrosion in flowing sulphuric acid was much more severe than in stagnant one, and the behavior of the hybrid modified ferrocement under sustained load and flowing sulphuric acid solution was noticeably better than that of control specimens.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. Singh G, Venn A, IP L, Xiong GJ. Alternative material and design for renovating man-entry sewers. In: Proceeding of the fourth international conference and exhibition on trenchless construction for utilities, London, UK, 1989. p. 2.3.1–7
2. Lea · 1970 · 667
3. Proposed revision of guide to durable concrete
4. Mehta · 1991 · 46
5. Sulphuric acid resistance of soluble soda glass-polyvinyl acetate latex-modified cement mortar10.1016/S0008-8846(00)00426-9 ↗
6. Guide for the design, construction and repair of ferrocement
7. Rational evaluation of flexural behavior of weldmesh ferrocement in normal and corrosive environments