Effect of preparation parameters on the properties of hydroxyapatite containing micro-arc oxidation coating on biodegradable ZK60 magnesium alloy
Source abstract
Abstract
Abstract Recently, micro-arc oxidation (MAO) is intensely studied as a promising surface treatment method for biodegradable magnesium alloys due to the excellent wear resistance and bonding strength of the MAO coating. In order to improve the bioactivity of the coating, hydroxyapatite (HA) nano-particles were added in the MAO electrolyte in the present study to prepare HA containing MAO coatings on the biodegradable ZK60 magnesium alloy. The HA concentration in the electrolyte, the preparation voltage and oxidation time were adjusted to prepare coatings with different morphologies, composition and properties. It was found that the coating was greatly influenced by these three parameters. The immersion test demonstrated that the HA containing MAO coating owned increased bioactivity and long-term protective ability compared with the base coating. A HA containing coating with good combination of corrosion resistance and phase composition could be obtained by properly selecting the above parameters.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
2. Comparison of degradation behavior and the associated bone response of ZK60 and PLLA in vivo
3. Biocompatibility of rapid-solidified magnesium alloy RS66 as a temporary biodegradable metal10.1016/j.actbio.2013.02.015 ↗
4. Bone-implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control10.1016/j.actbio.2010.08.020 ↗
5. Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone10.1016/j.actbio.2011.11.008 ↗
6. Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study10.1186/1475-925X-12-62 ↗
7. Surface design of biodegradable magnesium alloys — a review10.1016/j.surfcoat.2012.10.009 ↗
8. Biomedical coatings on magnesium alloys – a review10.1016/j.actbio.2012.04.012 ↗
9. Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg–Ca alloy10.1016/j.actbio.2010.11.034 ↗
10. The in vitro degradation process and biocompatibility of a ZK60 magnesium alloy with a forsterite-containing micro-arc oxidation coating10.1016/j.actbio.2012.12.016 ↗
11. In vivo degradation performance of micro-arc-oxidized magnesium implants: a micro-CT study in rats10.1016/j.actbio.2012.09.017 ↗
12. In vivo degradation and tissue compatibility of ZK60 magnesium alloy with micro-arc oxidation coating in a transcortical model10.1016/j.msec.2013.05.023 ↗
13. Calcium orthophosphates10.1007/s10853-006-1467-8 ↗
14. Calcium phosphate coatings on magnesium alloys for biomedical applications: a review10.1016/j.actbio.2011.10.016 ↗
15. Calcium phosphate coatings for bio-implant applications: materials, performance factors, and methodologies10.1016/j.mser.2009.05.001 ↗
16. Biodegradable magnesium-hydroxyapatite metal matrix composites10.1016/j.biomaterials.2006.12.027 ↗
17. Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: a randomised prospective study10.1016/j.injury.2010.03.030 ↗
18. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants10.1302/0301-620X.75B2.8444949 ↗
19. Formation of bioceramic coatings containing hydroxyapatite on the titanium substrate by micro-arc oxidation coupled with electrophoretic deposition10.1002/jbm.b.31724 ↗
20. Development and characterization of MgO/hydroxyapatite composite coating on AZ31 magnesium alloy by plasma electrolytic oxidation coupled with electrophoretic deposition10.1016/j.matlet.2011.11.025 ↗
21. Synthesis of biphasic calcium phosphate containing nanostructured films by micro arc oxidation on magnesium alloy10.1016/j.matchemphys.2013.06.045 ↗
22. Growth characteristics and corrosion resistance of micro-arc oxidation coating on pure magnesium for biomedical applications10.1016/j.corsci.2010.03.008 ↗
23. Effect of TiO2 nanoparticles on the microstructure and corrosion behavior of MAO coatings on magnesium alloy10.1002/maco.201106251 ↗
24. Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation10.1016/j.apsusc.2009.02.082 ↗
25. A preliminary study of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy10.1007/s10853-009-4093-4 ↗
26. Characterization of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy10.1016/j.apsusc.2010.01.069 ↗
27. Synthesis and properties of CaTiO3-containing coating on AZ31 magnesium alloy by micro-arc oxidation10.1016/j.matlet.2012.11.017 ↗
28. Effects of phosphates on microstructure and bioactivity of micro-arc oxidized calcium phosphate coatings on Mg–Zn–Zr magnesium alloy10.1016/j.colsurfb.2013.03.026 ↗
29. Preparation and bioactivity of micro-arc oxidized calcium phosphate coatings10.1016/j.matchemphys.2013.06.013 ↗
30. Bioactive Ca–P coating with self-sealing structure on pure magnesium
31. Potential bioactivity of coatings formed on AZ91D magnesium alloy by plasma electrolytic anodizing10.1002/jbm.b.32752 ↗
32. Formation of oxygen bubbles and its influence on current efficiency in micro-arc oxidation process of AZ91D magnesium alloy10.1016/j.tsf.2005.03.050 ↗
33. The potential energy curve for the B 3∑− u state of oxygen and accurate franck-condon factors for the Schumann–Runge bands10.1006/jmsp.1994.1002 ↗
34. Growth regularity of ceramic coating on magnesium alloy by plasma electrolytic oxidation10.1016/j.jallcom.2008.01.069 ↗
35. Control of magnesium corrosion and biocompatibility with biomimetic coatings10.1002/jbm.b.31742 ↗
36. Effect of surface pre-treatments on biocompatibility of magnesium10.1016/j.actbio.2009.04.018 ↗
37. Microstructure and biological properties of micro-arc oxidation coatings on ZK60 magnesium alloy10.1002/jbm.b.32726 ↗
38. Biodegradation behavior of micro-arc oxidized AZ31 magnesium alloys formed in two different electrolytes10.1016/j.apsusc.2012.07.105 ↗
39. Corrosion mechanism and model of pulsed DC microarc oxidation treated AZ31 alloy in simulated body fluid10.1016/j.apsusc.2012.03.016 ↗
40. Fabrication and degradation behavior of micro-arc oxidized biomedical magnesium alloy wires10.1016/j.surfcoat.2012.10.078 ↗
41. Long-term corrosion inhibition mechanism of microarc oxidation coated AZ31 Mg alloys for biomedical applications10.1016/j.matdes.2012.09.056 ↗
42. Biodegradation of four calcium phosphate ceramics;in vivo rates and tissue interactions
43. Comparison of electrochemical corrosion behaviour of MgO and ZrO2 coatings on AM50 magnesium alloy formed by plasma electrolytic oxidation10.1016/j.corsci.2009.06.034 ↗